ADC HBG76の取扱説明書

22ページ 0.49 mb
ダウンロード

ページに移動 of 22

Summary
  • ADC HBG76 - page 1

    HBG76 Installa tion/Oper a tor Manual ADC Part No. 1 13615 - 2 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA T elephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry .com ww w .amdry .com A VERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimu ...

  • ADC HBG76 - page 2

    2 American Dryer Corp. 1 13615 - 2 “IMPORT ANT NO TE T O PUR CHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer . FOR Y OUR SAFETY Do not store or use gasoline or other flammable vapors and liquids i ...

  • ADC HBG76 - page 3

    1 1361 5 - 2 ww w .amdry .com 3 T able of Contents ______ Proposition 65 Use of this product could expose you to substances from fuel combustion that contain chemicals known to the State of Califor nia to cause cancer , birth defects and other r eproductive harm. ▲ WARNING ! IMPORT ANT Y ou must disconnect and lockout the electric supply and the ...

  • ADC HBG76 - page 4

    4 American Dryer Corp. 1 13615 - 2 Safety Precautions ___________________ Wa r ning For your safety , the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury , or loss of life. The dryer must never be operated with any of the back guards, outer top s, or service panel ...

  • ADC HBG76 - page 5

    1 13615 - 2 ww w .amdry .com 5 The “Cool Down” Cycle of tumble dryers should be used to reduce the temperature of the items. They should not be removed from the tumble dryer or piled or stacked while hot. Fabric softeners or similar product s should not be used in a tumble dryer to eliminate the effect s of the static electricity , unless this ...

  • ADC HBG76 - page 6

    6 American Dryer Corp. 1 13615 - 2 M AXI M UM CAP ACI T Y ( DR Y WE I G H T ) 7 5 l b 34.02 kg T U M BLER DI AM ET ER 3 7 ” 93.98 cm T U M B L E R D E P T H 35- 1/ 2” 90.17 cm T UM B LE R V OLU ME 2 2 . 0 9 c u f t 625.52 L TUM B L E R/D RIV E M O TO R 3 / 4 h p 0.56 kW BLO W ER / F AN M O T O R 3 / 4 hp 0.56 kW D OOR OP E NI NG (D I A ME T E R ...

  • ADC HBG76 - page 7

    1 1361 5 - 2 ww w .amdry .com 7 Specifications _____________________________________________________________________ ...

  • ADC HBG76 - page 8

    8 American Dryer Corp. 1 13615 - 2 Installation Procedures ______________ Installation should be performed by competent professional in accordance with local, state, and country codes. In the absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.1- LA TEST EDITION (National Fuel Gas Code) or ANS ...

  • ADC HBG76 - page 9

    1 13615 - 2 ww w .amdry .com 9 ! F r esh Air Suppl y Requirements ______ When the dryer is operating, it draws in room air , heats it, passes this air through the tumbler , and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficien ...

  • ADC HBG76 - page 10

    10 American Dryer Corp. 1 13615 - 2 NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction. Multiple Dr y er (Common) V enting Important: For extended ductwork ...

  • ADC HBG76 - page 11

    1 13615 - 2 ww w .amdry .com 11 NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction. Multiple Dryer V enting with 8-Inch (20.32 cm) Diameter 640 cfm (18.12 c ...

  • ADC HBG76 - page 12

    12 American Dryer Corp. 1 13615 - 2 10/14/08 Grounding A ground (earth) connection must be provided and installed in accordance with local, state, and national regulations or codes of the country of origin. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO. 70-LA TEST EDIT ...

  • ADC HBG76 - page 13

    1 13615 - 2 ww w .amdry .com 13 3-Phase (3ø) Wiring Connections / Hookup Gas Infor mation ______________________ It is your responsibility to have all plumbing connections, materials, and workmanship conform to local and state regulations or codes of the country of destination. In the absence of such codes, all plumbing connections, materials, and ...

  • ADC HBG76 - page 14

    14 American Dryer Corp. 1 13615 - 2 Piping/Connections Inlet Connection – 1/2” M.N.P .T . CE and Australian dryer connections will be B.S.P .T ., all others will be N.P .T . There should be a minimum 6-inch (15.24 cm) clearance between the back guard and the first bend in the gas piping for ease of servicing. It is recommended that a gas shutof ...

  • ADC HBG76 - page 15

    1 1361 5 - 2 ww w .amdry .com 15 Gas Pr essure T esting _________________ For proper operation, the gas pressure must be correct, consistent and maintained at the gas pressure rates shown on page 14. Provisions are made at the gas valve for t aking gas pressure readings. There are 2 types of devices used to measure gas pressure. They are the spring ...

  • ADC HBG76 - page 16

    16 American Dryer Corp. 1 13615 - 2 ! Wa ter Infor mation ____________________ Before Y ou Star t Check Local Codes and P er mits Call your local water company or the proper municip al authority for information regarding local codes. Important: It is your responsibility to have all plumbing connections made by a qualified professional to ensure tha ...

  • ADC HBG76 - page 17

    1 13615 - 2 ww w .amdry .com 17 Wa r ning Electrical power must be provided to the dryer at all times. If the main electrical power supply to the dryer is disconnected, the fire suppression system is inoperative!! Prepar ation f or Opera tion/Star t-Up __ The following items should be checked before attempting to operate the dryer: • Read all “ ...

  • ADC HBG76 - page 18

    18 American Dryer Corp. 1 13615 - 2 Non-Coin Models Micropr ocessor Controller (Computer) The L.E.D. display reads “READY” (no cycle in progress). Press the letter on the keypad corresponding to the cycle desired (e.g. key “D”). The dryer will then start (i.e. blower , tumbler , and heat). The L.E.D. display will read MANUAL DRYING CYCLE D, ...

  • ADC HBG76 - page 19

    1 13615 - 2 ww w .amdry .com 19 Warranty t ags (Part No. 450064) are available at “no charge” from ADC upon request. The company returning the p art(s) must clearly note the complete company name and address on the out side of the package. All returns must be properly packaged to ensure that they are not damaged in transit. Damage claims are th ...

  • ADC HBG76 - page 20

    20 American Dryer Corp. 1 13615 - 2 Data Label Infor mation ____________________________________________________________ Standar d Label When contacting ADC, the information on the data label is required to ensure proper service/parts assist ance. The data label is located at the upper left rear of the dryer behind the back guard. 1. Model Number ? ...

  • ADC HBG76 - page 21

    1 1361 5 - 2 ww w .amdry .com 21 NOTES __________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________________________________________ ...

  • ADC HBG76 - page 22

    ADC Part No. 1 13615 2 - 10/14/0 8 - 0 ...

メーカー ADC カテゴリー Clothes Dryer

ADC HBG76のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HBG76の取扱説明書
- ADCの製品カード
- パンフレット
- またはADC HBG76の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、ADC HBG76の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、ADC HBG76の取り付け説明書、サービスマニュアル、簡易説明書、またはADC HBG76のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、ADC HBG76の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

ADC HBG76デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがADC HBG76を使用するのを助ける技術的文書のことです。説明書は通常、全てのADC HBG76ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

ADCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. ADC HBG76の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははADC HBG76の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。ADC HBG76に関してこのドキュメントで見つけることができる全てのヒントの目次
3. ADC HBG76デバイスの基本機能を使うにあたってのヒント。 ADC HBG76のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。ADC HBG76に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるADC HBG76のメーカー/サービスへの連絡先に関する情報。

ADC HBG76についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもADC HBG76の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがADC HBG76で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください