    MANLEY LABORA TORIES, INC. MANLEY LABORA TORIES, INC. 13880 MAGNOLIA A VE. CHINO, CA. 91710 TEL: (909) 627-4256 F AX: (909) 628-2482 OWNER'S MANUAL MANLEY NEO-CLASSIC SE / PP 300B AMPLIFIER ...

  • Manley Labs 300B - page 2

    CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTING YOUR AMPLIFIER 5 DIAGRAM 2 TOP PANEL 6 BIAS PROCEDURES 7 OPERATIONAL NOTES 8 SPECIFICATIONS 9 WARRANTY 10 WARRANTY REGISTRATION 11 SECTION PAGE ...

  • Manley Labs 300B - page 3

    INTRODUCTION THANK YOU!... for choosing the Manley Neo-Classic SE / PP 300B Monoblock Amplifiers. The Manley Neo-Classic SE / PP 300B Amplifiers use only the best available components, with the shortest and cleanest signal path possible. These amps have the unique ability to switch from Single ended to Push-Pull topologies and the ability to adjust ...

  • Manley Labs 300B - page 4

    READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE Pay special attention to pin Pay special attention to pin Pay special attention to pin Pay special a ...

  • Manley Labs 300B - page 5

    MAINS CONNECTIONS Your amplifier has been factory set to the correct mains voltage for your country. The voltage setting is marked on the serial badge, located on the rear panel. Check that this complies with your local supply. Export units for certain markets have a moulded mains plug fitted to comply with local requirements. If your unit does not ...

  • Manley Labs 300B - page 6

    CONNECTING YOUR AMPLIFIER Setting up your amplifiers is rather easy. 1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your preamplifier. 2. Connect the interconnects from the output of the preamplifier or switching center to the RCA input on the top rear of the amplifiers. 3. Connect the hot or "+" speaker cable ...

  • Manley Labs 300B - page 7

    MANLEY SE / PP 300B TRIODE MONOBLOCK AMPLIFIER D E I H J Amplifier Overhead View A RCA Input Jack B Speaker Terminals C Mains input IEC/Switch module Mains fuse - Replace only with same type and value Power Switch D Tube 5U4 Rectifier E Tube 5U4 Rectifier F Power Tube 300B G Power Tube 300B H Bias trimmer ( for F & L ) I Bias trimmer ( for G &a ...

  • Manley Labs 300B - page 8

    OPERATIONAL NOTES SWITCHING SINGLE-ENDED 11 / PUSH-PULL 24: This amplifier has the unique feature of being able to choose between two circuit topologies. You are able to switch between each mode while the amplifier is turned on and playing music. In SINGLE-ENDED mode the amplifier uses both 300Bs in parallel. The advantage is a minimalist circuit r ...

  • Manley Labs 300B - page 9

    5.) The correct bias reading in "Single-Ended" mode is 550 mVDC. A reading of 540-560mVDC will be within specs. The bias in single-ended mode was set at the factory. If, however, the S-E bias reading is out of spec after warm up, the bias may be adjusted as follows: 6.) Carefully turn the amp on it's left side, Be sure to brace the a ...

  • Manley Labs 300B - page 10

    SPECIFICATIONS Vacuum Tubes: 2 x 300B (Output), 1 x 6SN7 (Driver), 1 x 6SL7 (Input) 2 x 5U4 (Rectifier) Output Power @ 1Khz SINGLE-ENDED: 5 dB FB - 11 Watts @ 3% THD. PUSH-PULL: 5 dB FB - 24 Watts @ 1.5% THD. Frequency Response +/- .5 dB SINGLE-ENDED: 5 dB FB - 15 Hz - 15 Khz (measured at 5 watts) PUSH-PULL: 5 dB FB - 10 Hz - 20 Khz Input Sensitivi ...

  • Manley Labs 300B - page 11

    W ARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year transferrable warranty is available upon proper registration of ownership within 30 days of date of first purchase. ...

  • Manley Labs 300B - page 12

    W ARRANTY REGISTRA TION We ask, grovel and beg that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 USA Or you may FAX this form in to: +1 (909) 628-2482 or you may fill in the online warranty registration form found in the Tech Support section o ...

メーカー Manley Labs カテゴリー Car Amplifier

Manley Labs 300Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 300Bの取扱説明書
- Manley Labsの製品カード
- パンフレット
- またはManley Labs 300Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Manley Labs 300Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Manley Labs 300Bの取り付け説明書、サービスマニュアル、簡易説明書、またはManley Labs 300Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Manley Labs 300Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Manley Labs 300Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがManley Labs 300Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのManley Labs 300Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Manley Labsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Manley Labs 300Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははManley Labs 300Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Manley Labs 300Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Manley Labs 300Bデバイスの基本機能を使うにあたってのヒント。 Manley Labs 300Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Manley Labs 300Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるManley Labs 300Bのメーカー/サービスへの連絡先に関する情報。

Manley Labs 300Bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもManley Labs 300Bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがManley Labs 300Bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)