    WHITE-RODGERS 90 SERIES 1F95-391 MUL TI-ST AGE/HEA T PUMP INST ALLA TION/CONFIGURA TION This White-Rodgers Digital Thermostat uses microcomputer technology to provide precise time, humidity , and temperature control. This thermostat offers the flexibility to design 1F95-391 : 7 Day programming; residen- tial applications. ELECTRICAL D A T A Electri ...

  • White Rodgers 1F95-391 - page 2

    A TTENTION! This product does not contain mercury . However , this product may replace a unit which contains mercury . Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury . W earing non-absorbent gloves, take up the spilled mercury with sand or other absorbent material and place into a container which can be seale ...

  • White Rodgers 1F95-391 - page 3

    HEA T PUMP TERMINAL OUTPUTS Refer to equipment manufacturers’ instruc- tions for specific system wiring information. Y ou can configure the thermostat for use with the following heat pump system types: HEA T PUMP TYPE 1. Single-stage compressor system; gas or electric backup. HEA T PUMP TYPE 2. Multi-stage or two- compressor system; gas or electr ...

  • White Rodgers 1F95-391 - page 4

    RESET SWITCH See the T roubleshooting section at the end of this document for more information about the function of this switch. E2/P SWITCH (DHM) TERMINAL FUNCTION The E2/P switch is located on the back of the thermostat body (see fig. 2). This switch controls how the DHM terminal will be energized. 1. In the P position (up) the DHM terminal will ...

  • White Rodgers 1F95-391 - page 5

    INST ALLER CONFIGURA TION BEFORE TURNING POWER ON, please read the following instructions. Befor e operating the system, you must configure the thermostat to operate properly with your equipment. The thermostat, as it comes from the factory , is configured to operate a standard multi- stage electric forced hot air system with a single stage air con ...

  • White Rodgers 1F95-391 - page 6

    INST ALLER T ABLE NOTE: You must be in the User Configuration Menu to enter the Installer Table. Firmly press TIME FWD and TIME BACK at same time and release to enter the Configuration Menu. 6 1 ML TI STG HEA T PUMP 2 HEA T PUMP (1) 2 Selects type of system. Selecting HEA T PUMP makes additional items for heat pump systems av ailable. 3 ELEC HEA T ...

  • White Rodgers 1F95-391 - page 7

    These numbers are approximate and represent operation with a typical system. Actual temperature differentials and run times may vary widely based on your building and equipment, as well as outdoor temperature conditions. COMPRESSOR OFF DELA Y Installer table, step 1 1 is available if the fossil fuel kit alternative option (PUMP OFF) is selected. Th ...

  • White Rodgers 1F95-391 - page 8

    The Service Button Menu allows you to view or program as many as 4 reminders that indicate when service is required. 1. Humidifiers = A programmable run time in hours to indicate on the LCD when the humidifier will need to be serviced. 2. Air Filters = A programmable run time in hours to indicate on the LCD when the filter will need to be serviced ...

  • White Rodgers 1F95-391 - page 9

    TR OUBLESHOO TING F AN OPERA TION If your system does not have a G terminal Connection, skip to HEA T/HUMIDITY section below . 1. Turn power on to the system. 2. Press PROGRAM RUN . 3. Press FA N until F AN ON is displayed. The fan should begin to operate. 4. Press FA N until F AN AUT O is displayed. The fan should stop operating, unless a call for ...

  • White Rodgers 1F95-391 - page 10

    Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker . Replace fuse or reset breaker . (Common Prob lems) 2. Furnace power switch to OFF . T ur n switch to ON. 3. Furnace blow er compar tment door or Replace door panel in proper position to engage panel loose or not properly installed. saf ety in ...

  • White Rodgers 1F95-391 - page 11

    Symptom P ossible Cause Corrective Action Thermostat Setting and Thermostat 1. Thermostat ther mometer setting requires The thermometer can be adjusted +/- 5 degrees. Thermometer Disagree adjustment. See T emperature Displa y Adjustment in the Operating Manual under Configuration. Thermostat Display Sho ws CHCK P AD, 1. Thermostat ser vice indicato ...

  • White Rodgers 1F95-391 - page 12

    The Emerson logo is a trademark and a service mar k of Emerson Electric Co. ...

メーカー White Rodgers カテゴリー Heat Pump

White Rodgers 1F95-391のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1F95-391の取扱説明書
- White Rodgersの製品カード
- パンフレット
- またはWhite Rodgers 1F95-391の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、White Rodgers 1F95-391の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、White Rodgers 1F95-391の取り付け説明書、サービスマニュアル、簡易説明書、またはWhite Rodgers 1F95-391のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、White Rodgers 1F95-391の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

White Rodgers 1F95-391デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWhite Rodgers 1F95-391を使用するのを助ける技術的文書のことです。説明書は通常、全てのWhite Rodgers 1F95-391ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

White Rodgersの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. White Rodgers 1F95-391の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWhite Rodgers 1F95-391の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。White Rodgers 1F95-391に関してこのドキュメントで見つけることができる全てのヒントの目次
3. White Rodgers 1F95-391デバイスの基本機能を使うにあたってのヒント。 White Rodgers 1F95-391のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。White Rodgers 1F95-391に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWhite Rodgers 1F95-391のメーカー/サービスへの連絡先に関する情報。

White Rodgers 1F95-391についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWhite Rodgers 1F95-391の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWhite Rodgers 1F95-391で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)