    WHITE-RODGERS 90 SERIES 1F95-391 MUL TI-ST AGE/HEA T PUMP INST ALLA TION/CONFIGURA TION This White-Rodgers Digital Thermostat uses microcomputer technology to provide precise time, humidity , and temperature control. This thermostat offers the flexibility to design 1F95-391 : 7 Day programming; residen- tial applications. ELECTRICAL D A T A Electri ...

  • White Rodgers 1F95-391 - page 2

    A TTENTION! This product does not contain mercury . However , this product may replace a unit which contains mercury . Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury . W earing non-absorbent gloves, take up the spilled mercury with sand or other absorbent material and place into a container which can be seale ...

  • White Rodgers 1F95-391 - page 3

    HEA T PUMP TERMINAL OUTPUTS Refer to equipment manufacturers’ instruc- tions for specific system wiring information. Y ou can configure the thermostat for use with the following heat pump system types: HEA T PUMP TYPE 1. Single-stage compressor system; gas or electric backup. HEA T PUMP TYPE 2. Multi-stage or two- compressor system; gas or electr ...

  • White Rodgers 1F95-391 - page 4

    RESET SWITCH See the T roubleshooting section at the end of this document for more information about the function of this switch. E2/P SWITCH (DHM) TERMINAL FUNCTION The E2/P switch is located on the back of the thermostat body (see fig. 2). This switch controls how the DHM terminal will be energized. 1. In the P position (up) the DHM terminal will ...

  • White Rodgers 1F95-391 - page 5

    INST ALLER CONFIGURA TION BEFORE TURNING POWER ON, please read the following instructions. Befor e operating the system, you must configure the thermostat to operate properly with your equipment. The thermostat, as it comes from the factory , is configured to operate a standard multi- stage electric forced hot air system with a single stage air con ...

  • White Rodgers 1F95-391 - page 6

    INST ALLER T ABLE NOTE: You must be in the User Configuration Menu to enter the Installer Table. Firmly press TIME FWD and TIME BACK at same time and release to enter the Configuration Menu. 6 1 ML TI STG HEA T PUMP 2 HEA T PUMP (1) 2 Selects type of system. Selecting HEA T PUMP makes additional items for heat pump systems av ailable. 3 ELEC HEA T ...

  • White Rodgers 1F95-391 - page 7

    These numbers are approximate and represent operation with a typical system. Actual temperature differentials and run times may vary widely based on your building and equipment, as well as outdoor temperature conditions. COMPRESSOR OFF DELA Y Installer table, step 1 1 is available if the fossil fuel kit alternative option (PUMP OFF) is selected. Th ...

  • White Rodgers 1F95-391 - page 8

    The Service Button Menu allows you to view or program as many as 4 reminders that indicate when service is required. 1. Humidifiers = A programmable run time in hours to indicate on the LCD when the humidifier will need to be serviced. 2. Air Filters = A programmable run time in hours to indicate on the LCD when the filter will need to be serviced ...

  • White Rodgers 1F95-391 - page 9

    TR OUBLESHOO TING F AN OPERA TION If your system does not have a G terminal Connection, skip to HEA T/HUMIDITY section below . 1. Turn power on to the system. 2. Press PROGRAM RUN . 3. Press FA N until F AN ON is displayed. The fan should begin to operate. 4. Press FA N until F AN AUT O is displayed. The fan should stop operating, unless a call for ...

  • White Rodgers 1F95-391 - page 10

    Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker . Replace fuse or reset breaker . (Common Prob lems) 2. Furnace power switch to OFF . T ur n switch to ON. 3. Furnace blow er compar tment door or Replace door panel in proper position to engage panel loose or not properly installed. saf ety in ...

  • White Rodgers 1F95-391 - page 11

    Symptom P ossible Cause Corrective Action Thermostat Setting and Thermostat 1. Thermostat ther mometer setting requires The thermometer can be adjusted +/- 5 degrees. Thermometer Disagree adjustment. See T emperature Displa y Adjustment in the Operating Manual under Configuration. Thermostat Display Sho ws CHCK P AD, 1. Thermostat ser vice indicato ...

  • White Rodgers 1F95-391 - page 12

    The Emerson logo is a trademark and a service mar k of Emerson Electric Co. ...

Fabbricante White Rodgers Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoWhite Rodgers 1F95-391 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici White Rodgers
- manuali per l’uso 1F95-391
- schede prodotto White Rodgers
- opuscoli
- o etichette energetiche White Rodgers 1F95-391
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso White Rodgers 1F95-391.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione White Rodgers 1F95-391, manuali di manutenzione, brevi manuali o manuali utente White Rodgers 1F95-391. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto White Rodgers 1F95-391.

Manuali per l’uso simili

Manuale completo del dispositivo White Rodgers 1F95-391, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare White Rodgers 1F95-391 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti White Rodgers 1F95-391.

Il manuale per l’uso completo White Rodgers, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale White Rodgers 1F95-391 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice White Rodgers 1F95-391, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per White Rodgers 1F95-391 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo White Rodgers 1F95-391 - che ci dovrebbe aiutare nei primi passi durante l'uso White Rodgers 1F95-391
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del White Rodgers 1F95-391
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio White Rodgers 1F95-391 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su White Rodgers 1F95-391?

Utilizza il modulo sottostante

Se non hai risolto il problema con White Rodgers 1F95-391 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con White Rodgers 1F95-391 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)