Manuale per l’uso White Rodgers 1F95CA-391

12 pagine 0.15 mb
Scarica

Vai alla pagina of 12

Summary
  • White Rodgers 1F95CA-391 - page 1

    WHITE-R ODGERS 90 SERIES 1F95CA-391 MUL TI-ST A GE/HEA T PUMP INST ALLA TION/CONFIGURA TION This White-Rodgers Digital Thermostat uses microcomputer technology to provide precise time, humidity , and temperature control. This thermostat offers the fle xibility to design 1F95CA-391 : 7 Day programming; residential applications. ELECTRICAL D A T A El ...

  • White Rodgers 1F95CA-391 - page 2

    A TTENTION! This product does not contain mercury . Howe ver , this product may replace a unit which contains mercury . Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury . W earing non-absorbent glo ves, take up the spilled mercury with sand or other absorbent material and place into a container which can be sea ...

  • White Rodgers 1F95CA-391 - page 3

    HEA T PUMP TERMINAL OUTPUTS Refer to equipment manufacturers’ instruc- tions for specific system wiring information. Y ou can conf igure the thermostat for use with the following heat pump system types: HEA T PUMP TYPE 1. Single-stage compressor system; gas or electric backup. HEA T PUMP TYPE 2. Multi-stage or two- compressor system; gas or elect ...

  • White Rodgers 1F95CA-391 - page 4

    RESET SWITCH See the T roubleshooting section at the end of this document for more information about the function of this switch. E2/P SWITCH (DHM) TERMINAL FUNCTION The E2/P switch is located on the back of the thermostat body (see fig. 2). This switch controls how the DHM terminal will be energized. 1. In the P position (up) the DHM terminal will ...

  • White Rodgers 1F95CA-391 - page 5

    INST ALLER CONFIGURA TION BEFORE TURNING PO WER ON, please read the f ollowing instructions. Bef ore operating the system, you must conf igure the thermostat to operate properly with your equipment. The thermostat, as it comes from the factory , is configured to operate a standard multi- stage electric for ced hot air system with a single stage air ...

  • White Rodgers 1F95CA-391 - page 6

    INST ALLER T ABLE NO TE: Y ou must be in the User Configuration Menu to enter the Installer T able. Firmly press TIME FWD and TIME BACK at same time and release to enter the Configuration Menu. 6 1 ML TI STG HEA T PUMP 2 HEA T PUMP (1) 2 Selects type of system. Selecting HEA T PUMP makes additional items for heat pump systems av ailable. 3 ELEC HEA ...

  • White Rodgers 1F95CA-391 - page 7

    These numbers are approximate and represent operation with a typical system. Actual temperature dif ferentials and run times may vary widely based on your building and equipment, as well as outdoor temperature conditions. COMPRESSOR OFF DELA Y Installer table, step 11 is av ailable if the fossil fuel kit alternative option (PUMP OFF) is selected. T ...

  • White Rodgers 1F95CA-391 - page 8

    The Service Button Menu allows you to vie w or program as many as 4 reminders that indicate when service is required. 1. Humidif iers = A programmable run time in hours to indicate on the LCD when the humidifier will need to be serviced. 2. Air Filters = A programmable run time in hours to indicate on the LCD when the filter will need to be service ...

  • White Rodgers 1F95CA-391 - page 9

    9 CHECK THERMOST A T OPERA TION F AN OPERA TION If your system does not hav e a G terminal Connection, skip to HEA TING SYSTEM section belo w . 1. T urn po wer on to the system. 2. Press PR OGRAM RUN . 3. Press FA N until F AN ON is displayed. The fan should begin to operate. 4. Press FA N until F AN A UTO is displayed. The f an should stop operati ...

  • White Rodgers 1F95CA-391 - page 10

    No Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker . Replace fuse or reset breaker . (Common Problems) 2. Fur nace power s witch to OFF . T urn switch to ON. 3. Fur nace blow er compar tment door or Replace door panel in proper position to engage panel loose or not properly installed. safety interlock or door s witch. No Heat 1. Pilot ...

  • White Rodgers 1F95CA-391 - page 11

    No Cool 1. SYSTEM button not pressed to displa y COOL . Set SYSTEM button until COOL is displayed and raise temperature below room temperature. 2. Loose connection to ther mostat or system. V erify ther mostat and system wires are securely attached. 3. Cooling system requires ser vice or Same procedure as diagnostic for No Heat ther mostat requires ...

  • White Rodgers 1F95CA-391 - page 12

    The Emerson logo is a trademark and a service mar k of Emerson Electric Co. Why does the system run with the setpoint and room temperature the same? How do I temporaril y Override the program and Hold Til Timing? In cooling, as the room temperature f alls you will ev entually reach the setpoint tem- perature . The system will contin ue to run until ...

Fabbricante White Rodgers Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoWhite Rodgers 1F95CA-391 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici White Rodgers
- manuali per l’uso 1F95CA-391
- schede prodotto White Rodgers
- opuscoli
- o etichette energetiche White Rodgers 1F95CA-391
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso White Rodgers 1F95CA-391.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione White Rodgers 1F95CA-391, manuali di manutenzione, brevi manuali o manuali utente White Rodgers 1F95CA-391. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto White Rodgers 1F95CA-391.

Manuali per l’uso simili

Manuale completo del dispositivo White Rodgers 1F95CA-391, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare White Rodgers 1F95CA-391 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti White Rodgers 1F95CA-391.

Il manuale per l’uso completo White Rodgers, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale White Rodgers 1F95CA-391 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice White Rodgers 1F95CA-391, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per White Rodgers 1F95CA-391 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo White Rodgers 1F95CA-391 - che ci dovrebbe aiutare nei primi passi durante l'uso White Rodgers 1F95CA-391
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del White Rodgers 1F95CA-391
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio White Rodgers 1F95CA-391 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su White Rodgers 1F95CA-391?

Utilizza il modulo sottostante

Se non hai risolto il problema con White Rodgers 1F95CA-391 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con White Rodgers 1F95CA-391 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)