  • White Rodgers 1F95CA-391 - page 1

    WHITE-R ODGERS 90 SERIES 1F95CA-391 MUL TI-ST A GE/HEA T PUMP INST ALLA TION/CONFIGURA TION This White-Rodgers Digital Thermostat uses microcomputer technology to provide precise time, humidity , and temperature control. This thermostat offers the fle xibility to design 1F95CA-391 : 7 Day programming; residential applications. ELECTRICAL D A T A El ...

  • White Rodgers 1F95CA-391 - page 2

    A TTENTION! This product does not contain mercury . Howe ver , this product may replace a unit which contains mercury . Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury . W earing non-absorbent glo ves, take up the spilled mercury with sand or other absorbent material and place into a container which can be sea ...

  • White Rodgers 1F95CA-391 - page 3

    HEA T PUMP TERMINAL OUTPUTS Refer to equipment manufacturers’ instruc- tions for specific system wiring information. Y ou can conf igure the thermostat for use with the following heat pump system types: HEA T PUMP TYPE 1. Single-stage compressor system; gas or electric backup. HEA T PUMP TYPE 2. Multi-stage or two- compressor system; gas or elect ...

  • White Rodgers 1F95CA-391 - page 4

    RESET SWITCH See the T roubleshooting section at the end of this document for more information about the function of this switch. E2/P SWITCH (DHM) TERMINAL FUNCTION The E2/P switch is located on the back of the thermostat body (see fig. 2). This switch controls how the DHM terminal will be energized. 1. In the P position (up) the DHM terminal will ...

  • White Rodgers 1F95CA-391 - page 5

    INST ALLER CONFIGURA TION BEFORE TURNING PO WER ON, please read the f ollowing instructions. Bef ore operating the system, you must conf igure the thermostat to operate properly with your equipment. The thermostat, as it comes from the factory , is configured to operate a standard multi- stage electric for ced hot air system with a single stage air ...

  • White Rodgers 1F95CA-391 - page 6

    INST ALLER T ABLE NO TE: Y ou must be in the User Configuration Menu to enter the Installer T able. Firmly press TIME FWD and TIME BACK at same time and release to enter the Configuration Menu. 6 1 ML TI STG HEA T PUMP 2 HEA T PUMP (1) 2 Selects type of system. Selecting HEA T PUMP makes additional items for heat pump systems av ailable. 3 ELEC HEA ...

  • White Rodgers 1F95CA-391 - page 7

    These numbers are approximate and represent operation with a typical system. Actual temperature dif ferentials and run times may vary widely based on your building and equipment, as well as outdoor temperature conditions. COMPRESSOR OFF DELA Y Installer table, step 11 is av ailable if the fossil fuel kit alternative option (PUMP OFF) is selected. T ...

  • White Rodgers 1F95CA-391 - page 8

    The Service Button Menu allows you to vie w or program as many as 4 reminders that indicate when service is required. 1. Humidif iers = A programmable run time in hours to indicate on the LCD when the humidifier will need to be serviced. 2. Air Filters = A programmable run time in hours to indicate on the LCD when the filter will need to be service ...

  • White Rodgers 1F95CA-391 - page 9

    9 CHECK THERMOST A T OPERA TION F AN OPERA TION If your system does not hav e a G terminal Connection, skip to HEA TING SYSTEM section belo w . 1. T urn po wer on to the system. 2. Press PR OGRAM RUN . 3. Press FA N until F AN ON is displayed. The fan should begin to operate. 4. Press FA N until F AN A UTO is displayed. The f an should stop operati ...

  • White Rodgers 1F95CA-391 - page 10

    No Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker . Replace fuse or reset breaker . (Common Problems) 2. Fur nace power s witch to OFF . T urn switch to ON. 3. Fur nace blow er compar tment door or Replace door panel in proper position to engage panel loose or not properly installed. safety interlock or door s witch. No Heat 1. Pilot ...

  • White Rodgers 1F95CA-391 - page 11

    No Cool 1. SYSTEM button not pressed to displa y COOL . Set SYSTEM button until COOL is displayed and raise temperature below room temperature. 2. Loose connection to ther mostat or system. V erify ther mostat and system wires are securely attached. 3. Cooling system requires ser vice or Same procedure as diagnostic for No Heat ther mostat requires ...

  • White Rodgers 1F95CA-391 - page 12

    The Emerson logo is a trademark and a service mar k of Emerson Electric Co. Why does the system run with the setpoint and room temperature the same? How do I temporaril y Override the program and Hold Til Timing? In cooling, as the room temperature f alls you will ev entually reach the setpoint tem- perature . The system will contin ue to run until ...

Manufacturer White Rodgers Category Heat Pump

Documents that we receive from a manufacturer of a White Rodgers 1F95CA-391 can be divided into several groups. They are, among others:
- White Rodgers technical drawings
- 1F95CA-391 manuals
- White Rodgers product data sheets
- information booklets
- or energy labels White Rodgers 1F95CA-391
All of them are important, but the most important information from the point of view of use of the device are in the user manual White Rodgers 1F95CA-391.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals White Rodgers 1F95CA-391, service manual, brief instructions and user manuals White Rodgers 1F95CA-391. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product White Rodgers 1F95CA-391.

A complete manual for the device White Rodgers 1F95CA-391, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use White Rodgers 1F95CA-391 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of White Rodgers 1F95CA-391.

A complete White Rodgers manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual White Rodgers 1F95CA-391 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the White Rodgers 1F95CA-391, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the White Rodgers 1F95CA-391, that we can find in the current document
3. Tips how to use the basic functions of the device White Rodgers 1F95CA-391 - which should help us in our first steps of using White Rodgers 1F95CA-391
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with White Rodgers 1F95CA-391
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of White Rodgers 1F95CA-391 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning White Rodgers 1F95CA-391?

Use the form below

If you did not solve your problem by using a manual White Rodgers 1F95CA-391, ask a question using the form below. If a user had a similar problem with White Rodgers 1F95CA-391 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)