    Instr uctions-P ar ts Merkur ® Heated Spra y P ac ka g es 313255F ENG For finishing and coating appli cations requiring heated ma terials, in hazardous or non-hazardous locations. For pr ofessional use onl y . See page 5 f or model inf ormation, including maximu m working pressures and appro v als. Important Safety Instru ctions Read all warnings ...

  • Graco Merkur 313255F - page 2

    Related Manua ls 2 313255F Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Merkur 28:1 Heated P ac kages (G28Wxx and G28Cxx) . . . . . . . . . . . . . . . . 6 ...

  • Graco Merkur 313255F - page 3

    Warnings 313255F 3 Wa r n i n g s The f ollowing w arnings are fo r the setup , use , grounding, maint enance, and rep air of this equipment. The e xclama- tion point symbol ale r ts you to a gener al warning and the hazar d symbol ref ers to proc edure-specific risk. Ref er bac k to these wa r nings . Additional, prod uct- specific wa r nings ma y ...

  • Graco Merkur 313255F - page 4

    Warnings 4 313255F EQUIPMENT MISUSE HAZARD Misuse can ca use death or serious injury . • Do not oper ate the unit when f atigue d or under the influence of drugs or alcohol. • Do not exceed the maximum w orkin g pressure or temperature rating of the lowest rated system component. See T echnical Dat a in all equipment man uals. • Do not lea ve ...

  • Graco Merkur 313255F - page 5

    Models 313255F 5 Models Chec k the identification plat e (ID) f or the 6-digit part number of y our pac kage. Use the f ollowing matrix and tab les to define the compon ents of yo ur pack age. F or e x ample, pa ckage number G30W80 repres ents a Mer kur package (G) , with a 30:1 r atio pump (30) , w all mounting (W) , an d the components sho wn f o ...

  • Graco Merkur 313255F - page 6

    Models 6 313255F Merkur 28:1 Heated P ac ka ges (G28Wxx and G28Cxx) Maximum Inlet Air Pressure: 100 psi ( 0.7 MPa, 7 bar) Maximum Fluid W orking Pressure: 2800 psi (19.3 MP a, 193 bar) Merkur 30:1 Heated P ac ka ges (G30Wxx and G30Cxx) Maximum Inlet Air Pressure: 100 psi ( 0.7 MPa, 7 bar) Maximum Fluid W orking Pressure: 3000 psi (20.7 MP a, 207 ba ...

  • Graco Merkur 313255F - page 7

    Models 313255F 7 Merkur 48:1 Heated P ac ka ges (G48Wxx) Maximum Inlet Air Pressure: 100 psi (0 .7 MP a, 7 bar) Maximum Fluid W orking Pressure: 4800 psi (33.1 MP a, 331 bar) 0 Model Pump Assembly Heater Gun Air Controls Hose Options Maximum Fluid Fl ow Rate gpm (lpm) Wa l l Mount Cart Mount Pump Only Pump and Gun Gun Fluid Hose Gun Fluid Whip Hose ...

  • Graco Merkur 313255F - page 8

    Installation 8 313255F Installation Key: A Air Shutoff V alve (optional accessor y) B Air Filter (optional accessor y) C Air Line Moisture T rap and Drain V alve (optional accessor y) D Fluid Heater E Back Pressure Regulator F Fluid Filter G Fluid Drain V alve HS p r a y G u n J Gun Swivel K Fluid Whip Hose L Electrically Cond uctive , Air and Heat ...

  • Graco Merkur 313255F - page 9

    Installation 313255F 9 General Inf ormation F IG . 1 is only a guide f or selecting and installing system components and accessories . Contact you r Graco dis- tributor f or a ssistance in designing a system to suit your par ticula r needs. Prepare the Operator All persons who oper ate the equipment must be tr ained in the opera tion of all system ...

  • Graco Merkur 313255F - page 10

    Installation 10 313255F Supplied Components See F IG . 1. Components vary b y pac kage ordere d. See tab les on pages 6 to 7. Y our package ma y include: • The red-h andled bleed-type master air valve (U) is required in your syste m to reliev e air trapped between it and the air moto r and gun when the v a lve is closed. Do not block access to th ...

  • Graco Merkur 313255F - page 11

    Installation 313255F 11 Gr ounding The equipment m ust be ground ed. Grounding reduce s the risk of static and electric shock b y provid ing an escape wire f or the electrical curren t due to static b uild up or in the e v ent of a sh or t circuit. 1. Pump: See F IG . 2. V erify that the g round scre w (GS) is attached and t ightened secure ly to t ...

  • Graco Merkur 313255F - page 12

    Installation 12 313255F Electrical Housing Access Tilt the heater a wa y from the pump f or easier access to the scre ws on the cov e r of the electrical housing. Hose Connections See F IG . 1, page 8. 1. Attach one end of the air hose t o the gun air regula- tor (T , G40 spra y guns only). 2. Attach the other e nd of the air hose to t he air inlet ...

  • Graco Merkur 313255F - page 13

    Operation 313255F 13 Operation Pressure Relief Pr ocedure 1. Enga ge the tr igger lock. 2. See F IG . 1. T ur n off the b leed-type ma ster air v alv e (U). 3. Disengage the trigger loc k. 4. Hold a metal par t of the gun firmly to a grounded metal wast e container . T rigger the gun to relie v e fluid pressu re. 5. Enga ge the tr igger lock. 6. Op ...

  • Graco Merkur 313255F - page 14

    Operation 14 313255F We t C u p Bef ore star ting, fill wet cup 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solv ent. Prime the Pump 1. See F IG . 1. Lock gun trigger. Remo ve tip guard and spra y tip from gu n (H). Refer to gun manual. 2. Close gun air regulator (T) an d pump air regulator (X) b y tur ning knobs counterclockwise red ...

  • Graco Merkur 313255F - page 15

    Operation 313255F 15 Adjust the Atomization 1. Do not turn on atomizing air supply . Fluid pressure is controlled b y the air pressur e supplied to the pump (pump a ir regulator) . Set fluid pressure at low star ting pressure. F or low viscosity fluids (less than 25 sec, #2 Zahn cup) with lo wer percent solids ( typi- cally less than 40%), star t a ...

  • Graco Merkur 313255F - page 16

    Operation 16 313255F 3. See F IG . 7. For narrower patter n, tu r n patter n adjustment v alv e knob (AA) countercloc kwise (out). If pattern is still not nar row enough, increase air pressure to gun slightly or use different size tip . Shutdown F ollow Pressure Re lief Pr ocedure , p age 13. Alwa ys flush t he pump bef ore t he fluid dries on the ...

  • Graco Merkur 313255F - page 17

    Maintenance 313255F 17 Maintenance Preventive Maintenance Schedule The oper ating conditio ns of y our particular system determine how often maintenance is req uired. Estab lish a prev entive maintenance sched ule by recording when and what kind of maintena nce is needed, and then deter mine a regular schedule f or checking y our system. Replace le ...

  • Graco Merkur 313255F - page 18

    Troubleshooting 18 313255F T roub leshooting NO TE: Check all possible prob lems and causes before disassemb ling the pump . F * T o deter mine if the fluid hose or gun is obstructed, relie v e the pressure. Disconnect the fluid hose and place a con- tainer at the p ump fluid outlet to catch an y fluid. T ur n on the air just e nough to star t the ...

  • Graco Merkur 313255F - page 19

    DataTrak Controls and In dicators 313255F 19 DataT rak Contro ls and Indicators Key for F IG . 8 AA Runaw a y Limit, in cycles per min ute (user settable; 00=OFF) AB Lower Displacement (user settab le) A C Flo w Rate Units (user settable to gpm [US], gpm [Imperial], oz/min [US], oz/min [Imperial], l/min, or cc/min) AD LED (f ault indicator when lit ...

  • Graco Merkur 313255F - page 20

    DataTrak Operation 20 313255F DataT rak Operation NO TE: The displa y (AE) will tur n off after 1 minute to sav e batter y life . Press any ke y to wake up the display . Setup Mode 1. See F IG . 8. Press and hold f or 5 seconds until Setup menu appears . 2. T o enter se ttings f or runa wa y (i f equipped), lo wer size , and flo w rate unit s, and ...

  • Graco Merkur 313255F - page 21

    DataTrak Operation 313255F 21 Prime/Flush 1. See F IG . 8. T o enter Prime/Flush mode , press an y ke y to wake up the display , th en press . The Prime/Flush symbol will app ear in the displa y and the LED will flash . 2. While in Prime/Flush mode, runaw a y protect ion is disabled and the batch to taliz er (BT) will not count. The gr and totalize ...

  • Graco Merkur 313255F - page 22

    DataTrak Operation 22 313255F T able 1:Dia gnostic Codes Symbol Code Code Name Diagnosis Cause Runawa y (DataT rak only) Pump running faster than set runawa y limit. • I ncreased air pressure. • Increased fluid output. • Exhausted fluid supply . E-1 Diving Up Leak during upstroke . W orn piston va lv e or packi ngs. E-2 Diving Down Leak durin ...

  • Graco Merkur 313255F - page 23

    DataTrak Operation 313255F 23 Replace DataT rak Battery or Fuse Replace Battery 1. Unscrew cab le from the bac k of the reed s witch assembly . See F IG . 10 . 2. Re mov e the cable from the two cable clips. 3. Re mov e DataT rak modu le from brack et. See F IG . 11. T ake module and att ached cable t o a non-haz- ardous location. 4. Remov e two sc ...

  • Graco Merkur 313255F - page 24

    Parts 24 313255F Pa r t s NO TE: P ar ts v ar y by model. See P ar ts Lists on pages 26 to 28. 64 67 67 63 62 66 84 64 1 60 61 75 69 70 71 72 4 5 83a 83b 6 74 73 81 82 77 2 3a 3b ti13018a (wall mount models) (cart mount models) 48 76 G48xxx Models G28xxx and G30xxx Models 85 86 77 76 76 ...

  • Graco Merkur 313255F - page 25

    Parts 313255F 25 65 9 22 10 8 G40 Gun Shown ti13111a ti13143a ti13114a 16 16 Non-Hazardous Loca tion Electrical Cord Parts (120V Cart Mount Only) 79 80 65 49 54 53 68 ti13261a 60 60 78 (120V only) 50 51 ...

  • Graco Merkur 313255F - page 26

    Parts 26 313255F G28xxx Models ----- Not sold separately . NO TE: Replacement W arni ng labels, signs, tags, and cards are av ailable at no cost. Ref. No. P art No. Description Qty . 1 W28EAS W28EBS PUMP ASSEMBL Y M18LN0 x L W125A M18L T0 x L W125A 1 2 24A583 24A581 P ANEL, air controls Pump only (see page 31) Pump and gun, see page 30 1 3a 24A576 ...

  • Graco Merkur 313255F - page 27

    Parts 313255F 27 G30xxx Models ----- Not sold separately . NO TE: Replacement W arni ng labels, signs, tags, and cards are av ailable at no cost. Ref. No. P art No. Description Qty . 1 W30CAS W30CBS PUMP ASSEMBL Y M12LNO x L W075A M12L T0 x L W075A 1 2 24A583 24A581 P ANEL, air controls (includes 3b , 42, and 43) Pump only , see page 31 Pump and gu ...

  • Graco Merkur 313255F - page 28

    Parts 28 313255F G48Wxx Models ----- Not sold separately . NO TE: Replacement W arni ng labels, signs, tags, and cards are av ailable at no cost. Ref. No. P art No. Description Qty . 1 W48CAS W48CBS PUMP ASSEMBL Y M18LNO x L W075A M18L T0 x L W075A 1 2 24A581 P ANEL, air controls, pump an d gun (includes 3b , 42, and 43; see page 30 ) 1 3a 24A576 D ...

  • Graco Merkur 313255F - page 29

    Kits 313255F 29 Kits W all Mount Kit 24A578 NO TE: Mountin g Ar ms Kit 24A372 (P ar t 49, see page 26 or 27) also is required f or w all mounting a pac kage that has a control pa nel. Heated Car t Mount Kit 256427 102 101 ti12633a Ref No. Description Qty . 101 W ALL PLA TE, kit, includes screws 1 102 S CREW (included with 101) 4 201 202 209 203 207 ...

  • Graco Merkur 313255F - page 30

    Kits 30 313255F Pump and Gun Contr ol P anel Kit Kit 24A581 301 302 303 304 305 306 307 308 312 314 317 309 308 304 310 316 ti13565a 311 307 313 319 321 303 ti13467a 315 Ref. P art Description Qty . 301 114362 V AL VE, ball 1 302 15T643 SWIVEL, tee , 3/8 npt(m) x 1/2T 1 303 ----- TUBE, 1/2 OD , cut to fit, order T ubing Kit 24D496 1.3 ft. 304 12121 ...

  • Graco Merkur 313255F - page 31

    Kits 313255F 31 Pump Onl y Contr ol P anel Kit Kit 24A583 301 303 314 317 326 311 305 304 310 313 306 307 308 304 ti13567a Ref. P art Description Qty . 301 114362 V AL VE, ball 1 303 ----- TUBE, 1/2 OD , cut to fit, order T ubing Kit 24D496 1.5 ft. 304 121212 ELBO W , s wiv el, 1/2T x 3 /8 npt(m) 2 305 15T536 REGULA T OR, air , 3/8 npt 1 306 15T937 ...

  • Graco Merkur 313255F - page 32

    Kits 32 313255F DataT rak Kits Kit 24A576 (with Runawa y Pr otection) ----- Not so ld separately . ▲ Replacement W arning labels, signs , tags , and cards are av ailable at no cost. Kit 24C580 Replacemen t DataT rak fuse. Kit 24A592 (with Cycle Count Onl y) Optional con v ersion kit av ailab le f or pac kages with MxxLN0 air mo tors (air valv es ...

  • Graco Merkur 313255F - page 33

    Wall Bracket Moun ting Dimensions 313255F 33 W all Brac ket Mounting Dimensions Te c h n i c a l D a t a Maximum fluid working pres sure . . . . . . . . . . . . . . . See Models tab le on page 5. Maximum pump air inlet pressure . . . . . . . . . . . . . . 100 p si (0.7 MPa, 7.0 bar) Maximum gun w orking pressure . . . . . . . . . . . . . . . 100 ps ...

  • Graco Merkur 313255F - page 34

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions. Thi s manual contains Eng lish. MM 313255 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Kor ...

メーカー Graco カテゴリー Paint Sprayer

Graco Merkur 313255Fのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Merkur 313255Fの取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco Merkur 313255Fの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco Merkur 313255Fの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco Merkur 313255Fの取り付け説明書、サービスマニュアル、簡易説明書、またはGraco Merkur 313255Fのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco Merkur 313255Fの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco Merkur 313255Fデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco Merkur 313255Fを使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco Merkur 313255Fユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco Merkur 313255Fの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco Merkur 313255Fの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco Merkur 313255Fに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco Merkur 313255Fデバイスの基本機能を使うにあたってのヒント。 Graco Merkur 313255Fのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco Merkur 313255Fに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco Merkur 313255Fのメーカー/サービスへの連絡先に関する情報。

Graco Merkur 313255Fについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco Merkur 313255Fの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco Merkur 313255Fで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)