Campbell Manufacturing CS512の取扱説明書

16ページ 1.71 mb
ダウンロード

ページに移動 of 16

Summary
  • Campbell Manufacturing CS512 - page 1

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06 Copyright © 2001-2006 Campbell Scientific, Inc. ...

  • Campbell Manufacturing CS512 - page 2

    Warranty and Assistance The CS512 OXYGUARD TYPE III DISSOLVED OXYGEN PROBE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materi als and workmanship under norm al use and service for t welve (12) months from date of shipm ent unless specified otherwi se. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC. 's obligation ...

  • Campbell Manufacturing CS512 - page 3

    i CS512 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. General Information ..................................................... 1 2. Specifications .............................................................. 2 3. Optio ...

  • Campbell Manufacturing CS512 - page 4

    CS512 Table of Contents ii Examples 1. Sample Program using P1 .......................................................................... 5 2. Sample Program using P2 .......................................................................... 5 3. Sample Program using VoltSE .................................................................. 5 4. Sam ...

  • Campbell Manufacturing CS512 - page 5

    1 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe An accurate and reliable sensor is a critical element in any measurement system. The Oxyguard Stationary Probe meets these criteria for the measurement of dissolved oxygen. 1. General Information The Oxyguard Stationary Pro be is a galvanic prob e which produces a millivolt signal ...

  • Campbell Manufacturing CS512 - page 6

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 2 2. Specifications Principle of Measurem ent: Membrane covered galvanic oxygen probe Output Signal: 2.5 to 5 mV per m g 1 -1 Repeatability: Better than ± 0.2 mg/l calibration temperature equals measuring te mperature ± 5 ° C Output Impedance: ∼ 1 kohm Response Time: After equi ...

  • Campbell Manufacturing CS512 - page 7

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 3 3. Optional Probe Accessories PT4-L — Agitator for stagnant condi tions 18026 — DO electrolyte, 1 liter 18027 — Membrane kit , 10 mem branes 4. Optional Agitator The PT4 Agitator is a reli able and robust agitat or for use in conjunction with probes subjected to bio-fouling ...

  • Campbell Manufacturing CS512 - page 8

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 4 FIGURE 4-2. CS512 with PT4 Agitator Optional Repeat Cycle Timer for Agitators : Reciprocating act ion may be controlled by the opti onal solid state Repeat Cycle Tim er. It sends 12 VDC pulses to the agitator coil. The ON-time is 0.25 sec. The OFF-time is adjustab le from 3 to 12 ...

  • Campbell Manufacturing CS512 - page 9

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 5 7. Programming In the CR510, CR10X, and CR 23X datalogger, Instruction P1 or P2 can be used. Example 1 uses a single-ended m easurement for the CS512 probe; exampl e 2 uses a differential measurement. The exam ple measurem ent instructions that follow do not store data to final st ...

  • Campbell Manufacturing CS512 - page 10

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 6 8. Calibration The multiplier is used to calibrate the CS512 probe. To calculate the m ultiplier: 1) Program the datalogger using a multiplier of one. 2) Place the OxyGuard probe in the air, shad ed from the sun. Wait for readings to stabilize. This m ay take 15 m inutes or m ore. ...

  • Campbell Manufacturing CS512 - page 11

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 7 9. Maintenance The CS512 probe needs little maintenance. Regular cleaning of the m embrane is all that is required. The membrane is ve ry durable and can be cleaned with a cloth or soft paper. Do not scratch it cl ean with your fingernail. 10. Agitator Control In low flow conditio ...

  • Campbell Manufacturing CS512 - page 12

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 8 EXAMPLE 8. Sample Program using P86 and P22 Instructions 45: Do (P86) 1: 41 Set Port 1 Hi gh 46: Excitation with Delay (P22 ) 1: 1 Ex Channel 2: 20 Delay W/Ex (uni ts = 0.01 sec) 3: 0 Delay After Ex (uni ts = 0.01 sec) 4: 0 mV Excita tion 47: Do (P86) 1: 51 Set Port 1 Low 48: End ...

  • Campbell Manufacturing CS512 - page 13

    A-1 Appendix A. Dissolved Oxygen in Fresh Water Table ...

  • Campbell Manufacturing CS512 - page 14

    Appendix A. Dissolved Oxygen in Fre sh Water Table A-2 ...

  • Campbell Manufacturing CS512 - page 15

    This is a bl ank page . ...

  • Campbell Manufacturing CS512 - page 16

    Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 Nort h Logan, Utah 84 321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Afri ca Pty. Lt d. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Aust ralia Pty. Ltd. (CSA) PO Box 444 Thu ...

メーカー Campbell Manufacturing カテゴリー Oxygen Equipment

Campbell Manufacturing CS512のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CS512の取扱説明書
- Campbell Manufacturingの製品カード
- パンフレット
- またはCampbell Manufacturing CS512の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Campbell Manufacturing CS512の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Campbell Manufacturing CS512の取り付け説明書、サービスマニュアル、簡易説明書、またはCampbell Manufacturing CS512のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Campbell Manufacturing CS512の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Campbell Manufacturing CS512デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCampbell Manufacturing CS512を使用するのを助ける技術的文書のことです。説明書は通常、全てのCampbell Manufacturing CS512ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Campbell Manufacturingの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Campbell Manufacturing CS512の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCampbell Manufacturing CS512の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Campbell Manufacturing CS512に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Campbell Manufacturing CS512デバイスの基本機能を使うにあたってのヒント。 Campbell Manufacturing CS512のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Campbell Manufacturing CS512に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCampbell Manufacturing CS512のメーカー/サービスへの連絡先に関する情報。

Campbell Manufacturing CS512についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCampbell Manufacturing CS512の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCampbell Manufacturing CS512で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)