  • Campbell Manufacturing CS512 - page 1

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06 Copyright © 2001-2006 Campbell Scientific, Inc. ...

  • Campbell Manufacturing CS512 - page 2

    Warranty and Assistance The CS512 OXYGUARD TYPE III DISSOLVED OXYGEN PROBE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materi als and workmanship under norm al use and service for t welve (12) months from date of shipm ent unless specified otherwi se. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC. 's obligation ...

  • Campbell Manufacturing CS512 - page 3

    i CS512 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. General Information ..................................................... 1 2. Specifications .............................................................. 2 3. Optio ...

  • Campbell Manufacturing CS512 - page 4

    CS512 Table of Contents ii Examples 1. Sample Program using P1 .......................................................................... 5 2. Sample Program using P2 .......................................................................... 5 3. Sample Program using VoltSE .................................................................. 5 4. Sam ...

  • Campbell Manufacturing CS512 - page 5

    1 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe An accurate and reliable sensor is a critical element in any measurement system. The Oxyguard Stationary Probe meets these criteria for the measurement of dissolved oxygen. 1. General Information The Oxyguard Stationary Pro be is a galvanic prob e which produces a millivolt signal ...

  • Campbell Manufacturing CS512 - page 6

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 2 2. Specifications Principle of Measurem ent: Membrane covered galvanic oxygen probe Output Signal: 2.5 to 5 mV per m g 1 -1 Repeatability: Better than ± 0.2 mg/l calibration temperature equals measuring te mperature ± 5 ° C Output Impedance: ∼ 1 kohm Response Time: After equi ...

  • Campbell Manufacturing CS512 - page 7

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 3 3. Optional Probe Accessories PT4-L — Agitator for stagnant condi tions 18026 — DO electrolyte, 1 liter 18027 — Membrane kit , 10 mem branes 4. Optional Agitator The PT4 Agitator is a reli able and robust agitat or for use in conjunction with probes subjected to bio-fouling ...

  • Campbell Manufacturing CS512 - page 8

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 4 FIGURE 4-2. CS512 with PT4 Agitator Optional Repeat Cycle Timer for Agitators : Reciprocating act ion may be controlled by the opti onal solid state Repeat Cycle Tim er. It sends 12 VDC pulses to the agitator coil. The ON-time is 0.25 sec. The OFF-time is adjustab le from 3 to 12 ...

  • Campbell Manufacturing CS512 - page 9

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 5 7. Programming In the CR510, CR10X, and CR 23X datalogger, Instruction P1 or P2 can be used. Example 1 uses a single-ended m easurement for the CS512 probe; exampl e 2 uses a differential measurement. The exam ple measurem ent instructions that follow do not store data to final st ...

  • Campbell Manufacturing CS512 - page 10

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 6 8. Calibration The multiplier is used to calibrate the CS512 probe. To calculate the m ultiplier: 1) Program the datalogger using a multiplier of one. 2) Place the OxyGuard probe in the air, shad ed from the sun. Wait for readings to stabilize. This m ay take 15 m inutes or m ore. ...

  • Campbell Manufacturing CS512 - page 11

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 7 9. Maintenance The CS512 probe needs little maintenance. Regular cleaning of the m embrane is all that is required. The membrane is ve ry durable and can be cleaned with a cloth or soft paper. Do not scratch it cl ean with your fingernail. 10. Agitator Control In low flow conditio ...

  • Campbell Manufacturing CS512 - page 12

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 8 EXAMPLE 8. Sample Program using P86 and P22 Instructions 45: Do (P86) 1: 41 Set Port 1 Hi gh 46: Excitation with Delay (P22 ) 1: 1 Ex Channel 2: 20 Delay W/Ex (uni ts = 0.01 sec) 3: 0 Delay After Ex (uni ts = 0.01 sec) 4: 0 mV Excita tion 47: Do (P86) 1: 51 Set Port 1 Low 48: End ...

  • Campbell Manufacturing CS512 - page 13

    A-1 Appendix A. Dissolved Oxygen in Fresh Water Table ...

  • Campbell Manufacturing CS512 - page 14

    Appendix A. Dissolved Oxygen in Fre sh Water Table A-2 ...

  • Campbell Manufacturing CS512 - page 15

    This is a bl ank page . ...

  • Campbell Manufacturing CS512 - page 16

    Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 Nort h Logan, Utah 84 321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Afri ca Pty. Lt d. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Aust ralia Pty. Ltd. (CSA) PO Box 444 Thu ...

Fabricante Campbell Manufacturing Categoría Oxygen Equipment

Los documentos del dispositivo Campbell Manufacturing CS512 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Campbell Manufacturing
- manuales de instrucciones CS512
- hojas de producto Campbell Manufacturing
- folletos informativos
- o etiquetas energéticas Campbell Manufacturing CS512
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Campbell Manufacturing CS512.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Campbell Manufacturing CS512, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Campbell Manufacturing CS512. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Campbell Manufacturing CS512.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Campbell Manufacturing CS512, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Campbell Manufacturing CS512. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Campbell Manufacturing CS512.

El manual de instrucciones completo de Campbell Manufacturing debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Campbell Manufacturing CS512 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Campbell Manufacturing CS512, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Campbell Manufacturing CS512 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Campbell Manufacturing CS512 - que deben facilitarnos los primeros pasos durante el uso de Campbell Manufacturing CS512
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Campbell Manufacturing CS512
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Campbell Manufacturing CS512 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Campbell Manufacturing CS512?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Campbell Manufacturing CS512, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Campbell Manufacturing CS512 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)