Frymaster CEの取扱説明書

13ページ 0.52 mb
ダウンロード

ページに移動 of 13

Summary
  • Frymaster CE - page 1

    Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. Price: $6.00 24-Hour Service Hotline 1-800-551-8633 819-5726 10-99 Super Cascade Filtration Systems (CE) Operation Manual CE ONLY ...

  • Frymaster CE - page 2

    ...

  • Frymaster CE - page 3

    1 SUPER CASCADE FILTRATION SYSTEM OPERATION MANUAL TABLE OF CONTENTS PAGE 1. PARTS ORDERING AND SERVICE INFORMATION 1 2. GENERAL 2 3. FILTER PREPARATION 2 4. FILTER OPERATIONS 3 5. FILTER TROUBLESHOOTING 5 6. WIRING DIAGRAM 10 1. PARTS ORDERING AND SERVICE INFORMATION 1.1 ORDERING PARTS: Customers may order parts directly from their local Authorize ...

  • Frymaster CE - page 4

    2 2. GENERAL: a. The Flatbottom 24G (CE)/H250 Fryer System is equipped with the Super Cascade Filter Model 99. b. For consistent product quality, convenience and long-term savings, use a high-quality liquid frying compound. c. The frying compound should be filtered at least daily or even more frequently if cooking is heavy. This ensures the longest ...

  • Frymaster CE - page 5

    3 Hold down ring latched into position . 24G Drain Hole H250 Drain Hole Filter Pan Lid Drain Holes f. Unlatch and remove the hold down ring. Remove and discard old filter paper sheet from the filter pan. g. Clean out the filter pan. h. Place one sheet of filter paper in the bottom of the filter pan. Reinstall and latch the hold down ring into posit ...

  • Frymaster CE - page 6

    4 Air bubbles from the Oil Return Line 4. Open the oil return valve by turning the smaller red handle located under the control panel of the fryer. Move the handle left to right to open the oil return line. This will activate the filter pump also. 5. If the circuit breaker kicks out, this often means that there is an obstruction in the oil return l ...

  • Frymaster CE - page 7

    5 Drain Valve Handle Oil Return Handle H250 Drain & Oil Return Handles Air bubbles from the Oil Return Line b. H250 Fryers: 1. Turn the lower red drain valve handle from left to right to open the drain valve. The photo below shows the drain valve in the open position. 2. Stir the oil in the frypot with the L-shaped teflon brush as the oil drain ...

  • Frymaster CE - page 8

    6 5. FILTER TROUBLESHOOTING: The problems and possible solutions covered are those most commonly encountered. To troubleshoot, perform the test set-up at the beginning of each condition. Start at the top of the diagram. Arrows direct the troubleshooter through the sequence. Follow each step in sequence as shown in the troubleshooting diagrams. Trou ...

  • Frymaster CE - page 9

    7 5.2 RATE OF OIL RETURN SLOWING? Blockage may be between the filter pan bottom and the oil return valve. No No Yes No Has the oil return rate improved? Go to the flowchart titled "Blockage between Filter Pan and the Oil Return Valve. Rate of oil return to the fryer is slowing. Check the filter paper in the filter pan. Paper may not be secured ...

  • Frymaster CE - page 10

    8 5.3 BLOCKAGE BETWEEN FILTER PAN AND OIL RETURN VALVE? Does the pump motor run? Yes No Blockage has been determined to be between the filter pan bottom and the oil return valve. Disconnect oil line running from the filter pan to the pump at the pump end. Check filter circuit breaker. Push the filter circuit breaker reset button located in the righ ...

  • Frymaster CE - page 11

    9 Plug is in the bottom of the filter pan or in the line from the filter to the pump. Disconnect the tubing from the filter pan to the motor. Make sure the pipe is cool. The line is clear. Reconnect hose to the pump inlet. Can you blow air through it? Yes No The line is clogged. Run a cable through the line to clear clogs. Continue until you can bl ...

  • Frymaster CE - page 12

    10 6. WIRING DIAGRAM (Super Cascade Filter (CE), 230VAC/50Hz) Block 810-0164 Power Cord 807-1697 230 VAC 24 VAC Connection from Fryer SCF24MCD Oil Return Transformer/Relay Assy Relay 24V DPDT 501-0058 Add-on RH Fryer Relay 24V DPDT 501-0058 Add-on LH Fryer Relay 24V DPDT 501-0058 Oil Return Micro Switch (Polishing Valve) 501-0111 Oil Return Micro S ...

  • Frymaster CE - page 13

    Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address : 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 (Tech Support) 1-318-219-7135 Price: $6.00 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1-800-551-8633 819-5726 10-99 ...

メーカー Frymaster カテゴリー Water Dispenser

Frymaster CEのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CEの取扱説明書
- Frymasterの製品カード
- パンフレット
- またはFrymaster CEの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Frymaster CEの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Frymaster CEの取り付け説明書、サービスマニュアル、簡易説明書、またはFrymaster CEのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Frymaster CEの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Frymaster CEデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFrymaster CEを使用するのを助ける技術的文書のことです。説明書は通常、全てのFrymaster CEユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Frymasterの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Frymaster CEの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFrymaster CEの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Frymaster CEに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Frymaster CEデバイスの基本機能を使うにあたってのヒント。 Frymaster CEのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Frymaster CEに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFrymaster CEのメーカー/サービスへの連絡先に関する情報。

Frymaster CEについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFrymaster CEの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFrymaster CEで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)