Franklin SS-PCB50の取扱説明書

12ページ 0.7 mb
ダウンロード

ページに移動 of 12

Summary
  • Franklin SS-PCB50 - page 1

    P RODUCT S PECIFICA TIONS SS-PCB50 www .goodmanmfg.com 6/06 Supersedes 12/05 S ELF -C ONT AINED P ACKAGE A IR C ONDITIONER The PCB Commercial 50 Hz self-contained packaged air conditioner is designed for ground-level or rooftop application. PCB C OMMERCIAL S ERIES 50 Hz C OOLING C AP ACITY : 90,000 TO 180,000 BTU/ H 7½, 10, AND 15 T ON [26.4 kW to ...

  • Franklin SS-PCB50 - page 2

    2 SS-PCB50 P RODUCT S PECIFICA TIONS S PECIFICA TIONS PCB090-5 PCB120-5 PCB180-5 T otal Cooling - BTU/h (kW) 88,400 (25.9) 118,600 (34.8) 172,000 (50.4) Sensible Cooling - BTU/h¹ (kW) 67,100 (19.7) 89,200 (26.1) 131,000 (38.4) EER² 8.9 9.7 8.5 Indoor Blower (Qty .) 2 2 2 T ype Belt Belt Belt Size - D x W (mm) 12 x 12 (305 x 305) 12 x 15 (305 x 38 ...

  • Franklin SS-PCB50 - page 3

    SS-PCB50 3 P RODUCT S PECIFICA TIONS UNIT SIZE A - HEIGHT B - SUPPL Y AIR C - RETURN AIR 090 36” (914 mm) 12½” (318 mm) 179/16” (446 mm) 120,180 52” (1321 mm) 20¼” (514 mm) 2513/16” (656 mm) D IMENSIONS All dimensions in inches and millimeters. Drawings are not to scale. Note: The Horizontal Conversion K it is required to convert a fa ...

  • Franklin SS-PCB50 - page 4

    4 SS-PCB50 P RODUCT S PECIFICA TIONS E LECTRICAL C ONNECTIONS Main power entrance location (with electric heat installed) Control wiring entrance location Main power entrance location (without electric heat installed) Note: Single-point wiring is available at location #1 when heat kit is installed. See installation instructions for heat kits. 1– ...

  • Franklin SS-PCB50 - page 5

    SS-PCB50 5 P RODUCT S PECIFICA TIONS CFM EXTERNAL ST A TIC PRESSURE (INCHES W .C.) SEE NOTE (3) 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2600 669 0.44 816 0.59 916 0.75 1004 0.92 1084 1.09 1157 1.28 1226 1.47 1291 1.67 2800 734 0.53 847 0.69 944 0.85 1030 1.03 1109 1.21 1181 1.40 1249 1.60 1312 ...

  • Franklin SS-PCB50 - page 6

    6 SS-PCB50 P RODUCT S PECIFICA TIONS Motor Sheave - Adjustable Factory Setting F an Sheave - Fixed T wo T urns Opens Motor Sheave T urns Open 0 1 2 3 4 5 F an RPM 3.0 HP Motor 1242 1186 1129 1073 1016 960 Note: Allow ±5% variation in blower RPM due to pulley manufacturing tolerances. Conversion F actor: 1 CFM = 0.472 L/S 1” W .C. = 2.5 M Bar 1 H ...

  • Franklin SS-PCB50 - page 7

    SS-PCB50 7 P RODUCT S PECIFICA TIONS Motor Sheave - Adjustable Factory Setting F an Sheave - Fixed 2 T urns Opens Motor Sheave T urns Open 012345 F an RPM 5.0 HP Motor 1400 1446 1273 1209 1146 1082 Note: Allow ±5% variation in blower RPM due to pulley manufacturing tolerances. Conversion F actor: 1 CFM = 0.472 L/S 1” W .C. = 2.5 M Bar 1 HP = 0.7 ...

  • Franklin SS-PCB50 - page 8

    8 SS-PCB50 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 75°F 85°F 95°F 105°F 115°F SCFM WB To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw 2550 72 111.8 52.8 8.36 104.6 49.6 9.29 97.5 46.3 10.23 90.3 43.0 11.17 83.1 39.7 12.10 67 ...

  • Franklin SS-PCB50 - page 9

    SS-PCB50 9 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 23.9°C 29.4°C 35.0°C 40.6°C 46.1°C L/S WB T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw 2246 22.2 64.17 29.53 16.42 60.17 28.00 18.63 56.17 26.48 20.83 52.17 24.95 23.04 48.17 23.43 25.25 19. ...

  • Franklin SS-PCB50 - page 10

    10 SS-PCB50 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 75°F 85°F 95°F 105°F 115°F SCFM WB To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw 4760 72 219.0 100.8 16.42 205.3 95.6 18.63 191.7 90.4 20.83 178.0 85.1 23.04 164.4 79.9 2 ...

  • Franklin SS-PCB50 - page 11

    SS-PCB50 11 P RODUCT S PECIFICA TIONS F ACT OR Y S UPPLIED A CCESSORIES T HERMOST A T (CHT90-120) T wo-stage cool and two-stage heat thermostat with subbase, Manual changeover , Fan ON or AUT O. Note: A variety of thermostat con fi gurations can be used on this equipment based on the application needs. For example our CHTS36-60 can be used if two- ...

  • Franklin SS-PCB50 - page 12

    12 SS-PCB50 P RODUCT S PECIFICA TIONS Q UALITY M AKES THE D IFFERENCE ! All of our systems are designed and manufactured with the same high-quality standards, regardless of size or ef fi ciency . W e have designed these units to signi fi cantly reduce the most frequent causes of product failure. They are simple to service and forgiving to operate ...

メーカー Franklin カテゴリー Air Conditioner

Franklin SS-PCB50のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SS-PCB50の取扱説明書
- Franklinの製品カード
- パンフレット
- またはFranklin SS-PCB50の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Franklin SS-PCB50の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Franklin SS-PCB50の取り付け説明書、サービスマニュアル、簡易説明書、またはFranklin SS-PCB50のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Franklin SS-PCB50の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Franklin SS-PCB50デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFranklin SS-PCB50を使用するのを助ける技術的文書のことです。説明書は通常、全てのFranklin SS-PCB50ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Franklinの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Franklin SS-PCB50の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFranklin SS-PCB50の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Franklin SS-PCB50に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Franklin SS-PCB50デバイスの基本機能を使うにあたってのヒント。 Franklin SS-PCB50のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Franklin SS-PCB50に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFranklin SS-PCB50のメーカー/サービスへの連絡先に関する情報。

Franklin SS-PCB50についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFranklin SS-PCB50の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFranklin SS-PCB50で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)