Omega Engineering OS136の取扱説明書

16ページ 0.45 mb
ダウンロード

ページに移動 of 16

Summary
  • Omega Engineering OS136 - page 1

    OS136 SERIES Miniature Low-Cost Non-Contact Infrared T emperature Sensor/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at CA UTION! – This product is not intended for medical use or use on humans ...

  • Omega Engineering OS136 - page 2

    Servicing Nor th America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 USA Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: ...

  • Omega Engineering OS136 - page 3

    i OS136 Series Miniature Low-Cost Non-Contact Infrared T emperature Sensor/T ransmitter T able of Contents Section Page Caution and Safety Information .................................................................. iii Safety W arnings and IEC Symbols .............................................................. iii Section 1 Introduction ..... ...

  • Omega Engineering OS136 - page 4

    OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter ii List of Figures Figure Description Page 2-1 General W iring Diagram ................................................................ 2 3-1 Optical Field of V iew ...................................................................... 3 3-2 Mounting Bracket, OS100- ...

  • Omega Engineering OS136 - page 5

    OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter iii CAUTION & SAFETY INFORMA TION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impair ed. The Installation category is one (1). There is no user r eplaceable fuse in this product. The output t ...

  • Omega Engineering OS136 - page 6

    1 SECTION 1 - INTRODUCTION The model OS136 series is a very low-cost, super-compact infrar ed transmitter . It measures temperatur e via non-contact, and provides an analog output proportional to the measur ed temperature. The OS136 series is of fered in two temperature ranges: -18 to 204ºC (0 to 400ºF) and 149 to 538ºC (300 to 1000ºF). The ana ...

  • Omega Engineering OS136 - page 7

    2 2 The following describes the ordering information: OS136 – * – ** , where - * means: -1 : -18 to 204ºC (0 to 400ºF) T emperature range -2 : 149 to 538ºC (300 to 1000ºF) T emperature range - ** means: -MA : 4 to 20 mA current output -V1 : 0 to 5 Vdc output -V2 : 0 to 10 Vdc output -K : K type thermocouple output -MVC : 10 mV/ºC output -M ...

  • Omega Engineering OS136 - page 8

    3 Operation 3 SECTION 3 – OPERA TION 3.1 – Measuring T emperature Before starting to measur e temperature, make sur e the following check list is met:  The Power and output connections are made (Fig 2-1)  The target is lar ger than the optical field of view of the transmitter (Fig 3-1)  Use the Laser Sighting accessory (Optional), to a ...

  • Omega Engineering OS136 - page 9

    Operation 3 4 3.3 - Atmospheric Quality Environments with smoke , dust, and fume dirty up the optical lens, and cause erroneous temperatur e readings. T o keep the surface of the optical lens clean, the air purge collar accessory is r ecommended, OS136-AP (Fig 3-3). The following figures show the Mounting Bracket (OS136-MB), Air Purge Collar (OS136 ...

  • Omega Engineering OS136 - page 10

    Figure 3-4. Stainless Steel Housing Figure 3-5. Water/Air Cool Jacket, OS136-WC Figure 3-6. Water/Air Cool Jacket Assembly Operation 3 5 LIGHT HEX KNURL 4.76 ( 3 /16) WIDE DIMEN S ION S mm (in) 3 /4-16 UNF 88 .9 ( 3 .5) 1. 83 m (6ft) 33 .27 (1. 3 1) 19.05 (0.75) 1/ 8 NPT COMPRE SS ION FITTING, 2 PLC S . 3 4. 8 0 (1. 3 7) 8 5.09 ( 3 . 3 5) 7.62 (0. ...

  • Omega Engineering OS136 - page 11

    SECTION 4 - LASER SIGHT ACCESSOR Y 4.1 – W arning and Caution Y ou may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MA Y RESUL T IN HAZARDOUS RADIA TION EXPOSURE. • DO NOT LOOK A T THE LASER BEAM COMING ...

  • Omega Engineering OS136 - page 12

    7 Figure 4-1. Laser Sighting Accessory, OS100-LS Figure 4-2. Laser Warning Label Laser Sight Accessory 4 LASER W ARNING LABEL DC POWER JACK LED LASER POWER INDICA TOR LASER BEAM 19 (0.75) 50.8 (2.0) 38.1 (1.5) POWER CABLE ON/OFF SWITCH BA TTERY P ACK POWER SUPPL Y OS136 Dimen s ion s mm (in.) OUTPUT <1 mW, WAVELENGTH 6 3 0-670 nm, CLA SS II (2) ...

  • Omega Engineering OS136 - page 13

    Specifications 5 8 SECTION 5 – SPECIFICA TIONS 5.1 - General T emperature Range: OS136-1 -18 to 204ºC (0 to 400ºF) OS136-2 149 to 538ºC (300 to 1000ºF) Accuracy: @22ºC (72ºF) ambient OS136-1 3% of Rdg or 4.4ºC (8ºF) whichever is greater OS136-2 3% of Rdg or 5.5ºC (10ºF) whichever is greater From 185 to 510ºC (365 to 950ºF) Repeatabili ...

  • Omega Engineering OS136 - page 14

    Specifications 5 9 5.2 - Laser Sight Accessory Laser W avelength (Color): 630 - 670 nm (Red) Operating Distance: Up to 9.1 m (30 ft.) Max. Laser Power Output: Less than 1 mW @ 22ºC ambient European Classification: Class 2, EN60825-1/1 1.2001 FDA Classification: Class II Laser Product. Complies with 21 CFR 1040.10 Laser Beam Diameter: Less than 5 m ...

  • Omega Engineering OS136 - page 15

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from dat e o f p urch ase . OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s ...

  • Omega Engineering OS136 - page 16

    M3946/0806 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Co ...

メーカー Omega Engineering カテゴリー Stud Sensor

Omega Engineering OS136のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- OS136の取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering OS136の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering OS136の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering OS136の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering OS136のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering OS136の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Omega Engineering OS136デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering OS136を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering OS136ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering OS136の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering OS136の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering OS136に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering OS136デバイスの基本機能を使うにあたってのヒント。 Omega Engineering OS136のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering OS136に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering OS136のメーカー/サービスへの連絡先に関する情報。

Omega Engineering OS136についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering OS136の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering OS136で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)