Bedienungsanleitung Omega Engineering OS136

16 Seiten 0.45 mb
Download

Zur Seite of 16

Summary
  • Omega Engineering OS136 - page 1

    OS136 SERIES Miniature Low-Cost Non-Contact Infrared T emperature Sensor/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at CA UTION! – This product is not intended for medical use or use on humans ...

  • Omega Engineering OS136 - page 2

    Servicing Nor th America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 USA Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: ...

  • Omega Engineering OS136 - page 3

    i OS136 Series Miniature Low-Cost Non-Contact Infrared T emperature Sensor/T ransmitter T able of Contents Section Page Caution and Safety Information .................................................................. iii Safety W arnings and IEC Symbols .............................................................. iii Section 1 Introduction ..... ...

  • Omega Engineering OS136 - page 4

    OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter ii List of Figures Figure Description Page 2-1 General W iring Diagram ................................................................ 2 3-1 Optical Field of V iew ...................................................................... 3 3-2 Mounting Bracket, OS100- ...

  • Omega Engineering OS136 - page 5

    OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter iii CAUTION & SAFETY INFORMA TION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impair ed. The Installation category is one (1). There is no user r eplaceable fuse in this product. The output t ...

  • Omega Engineering OS136 - page 6

    1 SECTION 1 - INTRODUCTION The model OS136 series is a very low-cost, super-compact infrar ed transmitter . It measures temperatur e via non-contact, and provides an analog output proportional to the measur ed temperature. The OS136 series is of fered in two temperature ranges: -18 to 204ºC (0 to 400ºF) and 149 to 538ºC (300 to 1000ºF). The ana ...

  • Omega Engineering OS136 - page 7

    2 2 The following describes the ordering information: OS136 – * – ** , where - * means: -1 : -18 to 204ºC (0 to 400ºF) T emperature range -2 : 149 to 538ºC (300 to 1000ºF) T emperature range - ** means: -MA : 4 to 20 mA current output -V1 : 0 to 5 Vdc output -V2 : 0 to 10 Vdc output -K : K type thermocouple output -MVC : 10 mV/ºC output -M ...

  • Omega Engineering OS136 - page 8

    3 Operation 3 SECTION 3 – OPERA TION 3.1 – Measuring T emperature Before starting to measur e temperature, make sur e the following check list is met:  The Power and output connections are made (Fig 2-1)  The target is lar ger than the optical field of view of the transmitter (Fig 3-1)  Use the Laser Sighting accessory (Optional), to a ...

  • Omega Engineering OS136 - page 9

    Operation 3 4 3.3 - Atmospheric Quality Environments with smoke , dust, and fume dirty up the optical lens, and cause erroneous temperatur e readings. T o keep the surface of the optical lens clean, the air purge collar accessory is r ecommended, OS136-AP (Fig 3-3). The following figures show the Mounting Bracket (OS136-MB), Air Purge Collar (OS136 ...

  • Omega Engineering OS136 - page 10

    Figure 3-4. Stainless Steel Housing Figure 3-5. Water/Air Cool Jacket, OS136-WC Figure 3-6. Water/Air Cool Jacket Assembly Operation 3 5 LIGHT HEX KNURL 4.76 ( 3 /16) WIDE DIMEN S ION S mm (in) 3 /4-16 UNF 88 .9 ( 3 .5) 1. 83 m (6ft) 33 .27 (1. 3 1) 19.05 (0.75) 1/ 8 NPT COMPRE SS ION FITTING, 2 PLC S . 3 4. 8 0 (1. 3 7) 8 5.09 ( 3 . 3 5) 7.62 (0. ...

  • Omega Engineering OS136 - page 11

    SECTION 4 - LASER SIGHT ACCESSOR Y 4.1 – W arning and Caution Y ou may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MA Y RESUL T IN HAZARDOUS RADIA TION EXPOSURE. • DO NOT LOOK A T THE LASER BEAM COMING ...

  • Omega Engineering OS136 - page 12

    7 Figure 4-1. Laser Sighting Accessory, OS100-LS Figure 4-2. Laser Warning Label Laser Sight Accessory 4 LASER W ARNING LABEL DC POWER JACK LED LASER POWER INDICA TOR LASER BEAM 19 (0.75) 50.8 (2.0) 38.1 (1.5) POWER CABLE ON/OFF SWITCH BA TTERY P ACK POWER SUPPL Y OS136 Dimen s ion s mm (in.) OUTPUT <1 mW, WAVELENGTH 6 3 0-670 nm, CLA SS II (2) ...

  • Omega Engineering OS136 - page 13

    Specifications 5 8 SECTION 5 – SPECIFICA TIONS 5.1 - General T emperature Range: OS136-1 -18 to 204ºC (0 to 400ºF) OS136-2 149 to 538ºC (300 to 1000ºF) Accuracy: @22ºC (72ºF) ambient OS136-1 3% of Rdg or 4.4ºC (8ºF) whichever is greater OS136-2 3% of Rdg or 5.5ºC (10ºF) whichever is greater From 185 to 510ºC (365 to 950ºF) Repeatabili ...

  • Omega Engineering OS136 - page 14

    Specifications 5 9 5.2 - Laser Sight Accessory Laser W avelength (Color): 630 - 670 nm (Red) Operating Distance: Up to 9.1 m (30 ft.) Max. Laser Power Output: Less than 1 mW @ 22ºC ambient European Classification: Class 2, EN60825-1/1 1.2001 FDA Classification: Class II Laser Product. Complies with 21 CFR 1040.10 Laser Beam Diameter: Less than 5 m ...

  • Omega Engineering OS136 - page 15

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from dat e o f p urch ase . OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s ...

  • Omega Engineering OS136 - page 16

    M3946/0806 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Co ...

Produzent Omega Engineering Kategorie Stud Sensor

Dokumente, die wir vom Produzenten des Geräts Omega Engineering OS136 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Omega Engineering
- Bedienungsanleitungen OS136
- Produktkarten Omega Engineering
- Informationsbroschüren
- oder Energieetiketten Omega Engineering OS136
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Omega Engineering OS136.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Omega Engineering OS136, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Omega Engineering OS136. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Omega Engineering OS136 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Omega Engineering OS136, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Omega Engineering OS136 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Omega Engineering OS136 verständlich ist.

Eine gänzliche Bedienungsanleitung von Omega Engineering sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Omega Engineering OS136 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Omega Engineering OS136 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Omega Engineering OS136, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Omega Engineering OS136 - die uns die ersten Schritte während der Nutzung von Omega Engineering OS136 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Omega Engineering OS136 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Omega Engineering OS136 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Omega Engineering OS136?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Omega Engineering OS136 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Omega Engineering OS136 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)