Summary
  • White Rodgers 1F95-0671 - page 1

    Blue Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Model Programming Choices 1F95-0671 7 Day 5/1/1 Day Non-Programmab le www .white-rodgers .com P ART NO . 37-6979A 0908 Single Stage, Multi-Stage, Heat Pump Installation and Operating Instructions for Model: APPLICA TIONS THERMOST A T APPLICA TION GUIDE 1F95-0671 Universal T ...

  • White Rodgers 1F95-0671 - page 2

    2 Remove Old Thermostat Bef ore removing wires from old thermostat, mar k wires f or terminal identifi cation so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the ther mostat base. Forcing or pr ying on the thermostat will cause damage to the unit. 2. Place base ov er hole in w ...

  • White Rodgers 1F95-0671 - page 3

    3 WIRING DIA GRAMS Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single T ransf ormer Single Stage 1 (SS1) Multi- Stage 2 (MS2) O Energized Constantly in Cool Mode B Energized Constantly in Heat, Off, Emergency Mode No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator Fan Energized on Call for Cool (and Heat if ...

  • White Rodgers 1F95-0671 - page 4

    4 Single Stage 3-wire Zone V alve application Blower/Circulator Fan Energized Opens Va l v e (4) Constant 24 V olt (Com- mon) 24 V olt (Hot) Cool System 6 Y W C RC CLASS II TRANSFORMER HOT 24V AC NEUTRAL 120V AC 24 V olt (Hot) Heat (5) RH G Jumper Closes Va l v e (6) Figure 5 – 3-Wire (SPDT) Heat Only Zone V alve Wiring Figure 4 – Heat Pump Sys ...

  • White Rodgers 1F95-0671 - page 5

    5 Programming and Confi guration Items 1 "System On" indicates when heating or cooling stage is energized. "System On +2" indicates when addi tional stages are on. 2 The word " Hold" is displayed when the thermostat is in the HOLD mode. " T emp" is displayed when the thermostat is in a T emporary HOLD mode. ...

  • White Rodgers 1F95-0671 - page 6

    6 INST ALLER/CONFIGURA TION MENU Thermostat must be in Heat, Cool or Auto. Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below . Press Menu to advance to the next menu item. Press or to change a menu item options. INST ALLER/CONFIGURA TION MENU Menu Ref . HP SS Press Button Displa yed (F actor y D ...

  • White Rodgers 1F95-0671 - page 7

    7 INST ALLER/CONFIGURA TION MENU 21 20 18 MENU dS (On) Off Selects A utomatic Daylight Sa ving Time option 22 21 19 MENU (OFF) K eypad Lock out L, P , Limit Selects one of 3 K eypad Lock out confi gur ations L - T otal Ke ypad Lockout P - P ar tial K eypad Lock out (Up and K eys still work) Limit - Limited T emperature Range MENU (000) K eypad Loc ...

  • White Rodgers 1F95-0671 - page 8

    8 INST ALLER/CONFIGURA TION MENU 5, 6 & 7) Cycle Rate Selection – The f actor y def ault setting for Heat and Cool modes, SS1, MS2, is medium cycle (ME). F or Heat Pump , HP1, HP2, the default setting is medium (ME). For Emer (A ux) the default setting is f ast cycle (F A). T o change cycle rate , press the or button. Cycle rate diff erential ...

  • White Rodgers 1F95-0671 - page 9

    9 INST ALLER/CONFIGURA TION MENU 24) Limited Cool Range – This f eature provide a minimum setpoint temperature f or cool. The default setting is 45°F . It can be changed between 46°F and 82°F b y pressing the or button. 25) Select Compressor Off (CO) Feature Using Outdoor Sensor – This feature is applicab le only in heat pump modes and with ...

  • White Rodgers 1F95-0671 - page 10

    10 T o pre vent compressor and/or property damage, if the outdoor temperature is below 50°F , DO NO T operate the cooling system. CAUTION ! Cooling System 1. Press SYSTEM b utton to select Cool. 2. Press to adjust thermostat setting below room tem- perature. The blo wer should come on immediately on high speed, f ollowed b y cold air circulation. ...

  • White Rodgers 1F95-0671 - page 11

    11 PR OGRAMMING Energy Sa ving Factory Pre-Pr ogram The 1F95-0680 thermostats are programmed with the energy saving settings sho wn in the table belo w for all da ys of the week. If this program suits y our needs, simply set the ther mostat clock and press the RunSched b utton. The table belo w shows the f actor y set heating and cooling schedule f ...

  • White Rodgers 1F95-0671 - page 12

    12 A utomatic Daylight Sa ving Calculation The Real Time Clock will adjust automatically f or da ylight sav- ings time, in the f ollowing manner : Increment one hour at 2 AM on the second Sunda y of March and decrement one hour at 2 AM on the fi rst Sunda y of No- vember . (New DST eff ective 2007). The da ylight saving f eature can be enabled or ...

  • White Rodgers 1F95-0671 - page 13

    13 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 f eet). T er minals +, S and - on the terminal block allo w connection of the remote sensor . The thermostat must hav e 24 V AC Common connection to terminal C for the rem ...

  • White Rodgers 1F95-0671 - page 14

    14 Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blo wer compar tment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system. Replace fuse or reset breaker . T ur n s witch to ON. Replac ...

  • White Rodgers 1F95-0671 - page 15

    15 NO TES ...

  • White Rodgers 1F95-0671 - page 16

    www.white-rodgers.com White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. HOMEO WNER HELP LINE: 1-800-284-2925 ...

メーカー White Rodgers カテゴリー Thermostat

White Rodgers 1F95-0671のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1F95-0671の取扱説明書
- White Rodgersの製品カード
- パンフレット
- またはWhite Rodgers 1F95-0671の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、White Rodgers 1F95-0671の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、White Rodgers 1F95-0671の取り付け説明書、サービスマニュアル、簡易説明書、またはWhite Rodgers 1F95-0671のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、White Rodgers 1F95-0671の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

White Rodgers 1F95-0671デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWhite Rodgers 1F95-0671を使用するのを助ける技術的文書のことです。説明書は通常、全てのWhite Rodgers 1F95-0671ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

White Rodgersの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. White Rodgers 1F95-0671の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWhite Rodgers 1F95-0671の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。White Rodgers 1F95-0671に関してこのドキュメントで見つけることができる全てのヒントの目次
3. White Rodgers 1F95-0671デバイスの基本機能を使うにあたってのヒント。 White Rodgers 1F95-0671のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。White Rodgers 1F95-0671に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWhite Rodgers 1F95-0671のメーカー/サービスへの連絡先に関する情報。

White Rodgers 1F95-0671についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWhite Rodgers 1F95-0671の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWhite Rodgers 1F95-0671で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)