    Blue Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Model Programming Choices 1F95-0671 7 Day 5/1/1 Day Non-Programmab le www .white-rodgers .com P ART NO . 37-6979A 0908 Single Stage, Multi-Stage, Heat Pump Installation and Operating Instructions for Model: APPLICA TIONS THERMOST A T APPLICA TION GUIDE 1F95-0671 Universal T ...

  • White Rodgers 1F95-0671 - page 2

    2 Remove Old Thermostat Bef ore removing wires from old thermostat, mar k wires f or terminal identifi cation so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the ther mostat base. Forcing or pr ying on the thermostat will cause damage to the unit. 2. Place base ov er hole in w ...

  • White Rodgers 1F95-0671 - page 3

    3 WIRING DIA GRAMS Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single T ransf ormer Single Stage 1 (SS1) Multi- Stage 2 (MS2) O Energized Constantly in Cool Mode B Energized Constantly in Heat, Off, Emergency Mode No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator Fan Energized on Call for Cool (and Heat if ...

  • White Rodgers 1F95-0671 - page 4

    4 Single Stage 3-wire Zone V alve application Blower/Circulator Fan Energized Opens Va l v e (4) Constant 24 V olt (Com- mon) 24 V olt (Hot) Cool System 6 Y W C RC CLASS II TRANSFORMER HOT 24V AC NEUTRAL 120V AC 24 V olt (Hot) Heat (5) RH G Jumper Closes Va l v e (6) Figure 5 – 3-Wire (SPDT) Heat Only Zone V alve Wiring Figure 4 – Heat Pump Sys ...

  • White Rodgers 1F95-0671 - page 5

    5 Programming and Confi guration Items 1 "System On" indicates when heating or cooling stage is energized. "System On +2" indicates when addi tional stages are on. 2 The word " Hold" is displayed when the thermostat is in the HOLD mode. " T emp" is displayed when the thermostat is in a T emporary HOLD mode. ...

  • White Rodgers 1F95-0671 - page 6

    6 INST ALLER/CONFIGURA TION MENU Thermostat must be in Heat, Cool or Auto. Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below . Press Menu to advance to the next menu item. Press or to change a menu item options. INST ALLER/CONFIGURA TION MENU Menu Ref . HP SS Press Button Displa yed (F actor y D ...

  • White Rodgers 1F95-0671 - page 7

    7 INST ALLER/CONFIGURA TION MENU 21 20 18 MENU dS (On) Off Selects A utomatic Daylight Sa ving Time option 22 21 19 MENU (OFF) K eypad Lock out L, P , Limit Selects one of 3 K eypad Lock out confi gur ations L - T otal Ke ypad Lockout P - P ar tial K eypad Lock out (Up and K eys still work) Limit - Limited T emperature Range MENU (000) K eypad Loc ...

  • White Rodgers 1F95-0671 - page 8

    8 INST ALLER/CONFIGURA TION MENU 5, 6 & 7) Cycle Rate Selection – The f actor y def ault setting for Heat and Cool modes, SS1, MS2, is medium cycle (ME). F or Heat Pump , HP1, HP2, the default setting is medium (ME). For Emer (A ux) the default setting is f ast cycle (F A). T o change cycle rate , press the or button. Cycle rate diff erential ...

  • White Rodgers 1F95-0671 - page 9

    9 INST ALLER/CONFIGURA TION MENU 24) Limited Cool Range – This f eature provide a minimum setpoint temperature f or cool. The default setting is 45°F . It can be changed between 46°F and 82°F b y pressing the or button. 25) Select Compressor Off (CO) Feature Using Outdoor Sensor – This feature is applicab le only in heat pump modes and with ...

  • White Rodgers 1F95-0671 - page 10

    10 T o pre vent compressor and/or property damage, if the outdoor temperature is below 50°F , DO NO T operate the cooling system. CAUTION ! Cooling System 1. Press SYSTEM b utton to select Cool. 2. Press to adjust thermostat setting below room tem- perature. The blo wer should come on immediately on high speed, f ollowed b y cold air circulation. ...

  • White Rodgers 1F95-0671 - page 11

    11 PR OGRAMMING Energy Sa ving Factory Pre-Pr ogram The 1F95-0680 thermostats are programmed with the energy saving settings sho wn in the table belo w for all da ys of the week. If this program suits y our needs, simply set the ther mostat clock and press the RunSched b utton. The table belo w shows the f actor y set heating and cooling schedule f ...

  • White Rodgers 1F95-0671 - page 12

    12 A utomatic Daylight Sa ving Calculation The Real Time Clock will adjust automatically f or da ylight sav- ings time, in the f ollowing manner : Increment one hour at 2 AM on the second Sunda y of March and decrement one hour at 2 AM on the fi rst Sunda y of No- vember . (New DST eff ective 2007). The da ylight saving f eature can be enabled or ...

  • White Rodgers 1F95-0671 - page 13

    13 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 f eet). T er minals +, S and - on the terminal block allo w connection of the remote sensor . The thermostat must hav e 24 V AC Common connection to terminal C for the rem ...

  • White Rodgers 1F95-0671 - page 14

    14 Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blo wer compar tment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system. Replace fuse or reset breaker . T ur n s witch to ON. Replac ...

  • White Rodgers 1F95-0671 - page 15

    15 NO TES ...

  • White Rodgers 1F95-0671 - page 16

    www.white-rodgers.com White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. HOMEO WNER HELP LINE: 1-800-284-2925 ...

Производитель White Rodgers Категория Thermostat

Документы, которые мы получаем от производителя устройства White Rodgers 1F95-0671 мы можем разделить на несколько групп. Это в частности:
- технические чертежи White Rodgers
- инструкции обслуживания 1F95-0671
- паспорта изделия White Rodgers
- информационные брошюры
- энергетические этикетки White Rodgers 1F95-0671
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания White Rodgers 1F95-0671.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа White Rodgers 1F95-0671, инструкции обслуживания, короткие инструкции или инструкции пользователя White Rodgers 1F95-0671. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия White Rodgers 1F95-0671.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства White Rodgers 1F95-0671, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании White Rodgers 1F95-0671 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей White Rodgers 1F95-0671.

Полная инструкция обслуживания White Rodgers, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией White Rodgers 1F95-0671 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания White Rodgers 1F95-0671, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся White Rodgers 1F95-0671, которое найдем в данном документе
3. Советы по использованию основных функций устройства White Rodgers 1F95-0671 - которые должны облегчить нам первые шаги во время использования White Rodgers 1F95-0671
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем White Rodgers 1F95-0671
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра White Rodgers 1F95-0671 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся White Rodgers 1F95-0671?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с White Rodgers 1F95-0671, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с White Rodgers 1F95-0671 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)