    NOTE: Read the entire instruction manual before performing any service or maintenance. This symbol → indicates a change since the last issue. Index Page SAFETY CONSIDERATIONS ..................................................1-2 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS........2 GENERAL............................................................. ...

  • Bryant A93040 - page 2

    WARNING: Never store anything on, near, or in contact with the furnace, such as: 1. Spray or aerosol cans, rags, brooms, dust mops, vacuum cleaners, or other cleaning tools. 2. Soap powders, bleaches, waxes or other cleaning compounds, plastic or plastic containers, gasoline, kerosene, cigarette lighter fluid, dry cleaning fluids, or other volatile ...

  • Bryant A93040 - page 3

    8. Recapture filter retainer wire. 9. Replace blower access panel and main furnace door. 10. Turn on electrical supply to furnace. NOTE: If the filter has cross-mesh binding, the binding must face the blower. If the filter has an air direction arrow, the arrow must point toward the blower. II. BLOWER MOTOR AND WHEEL MAINTENANCE To ensure long life, ...

  • Bryant A93040 - page 4

    WARNING: Blower access panel door switch opens 115-v power to control center. No component operation can occur. Caution must be taken when manually closing this switch for service purposes. Failure to follow this warning could result in personal injury or death. 15. If furnace is operating properly, release blower access panel door switch, replace ...

  • Bryant A93040 - page 5

    10. Remove screws attaching burner box to cell panel. (See Fig. 5.) NOTE: Burner box, cover, manifold, gas valve, and burner assembly should be removed as 1 assembly. 11. Clean heat exchanger openings with a vacuum and a soft brush. (See Fig. 6.) NOTE: After cleaning, inspect the heat exchangers to ensure they are free of all foreign objects that m ...

  • Bryant A93040 - page 6

    Fig. 8—Furnace Pressure and Drain Tubing Diagram A94212 Furnace is shipped from factory in upflow configuration. Pressure tube and drain tube routing MUST match the diagram s below. 322094-101 REV. B NOTE: This appliance requires a special venting system. Refer to the installation instructions for parts list and method of installation. Furnace mu ...

  • Bryant A93040 - page 7

    12. Reconnect pressure tubes to pressure switches. See diagram on main furnace door for proper location of tubes. Be sure tubes are not kinked. (See Fig. 8.) 13. Turn on gas and electrical supplies to furnace. 14. Check furnace operation through 2 complete heat operating cycles. Check area below inducer housing, vent pipe, and condensate trap to en ...

  • Bryant A93040 - page 8

    The 24-v circuit contains an automotive-type, 3-amp fuse located on the control center. (See Fig. 12.) Any direct shorts of the 24-v wiring during installation, service, or maintenance will cause this fuse to blow. If fuse replacement is required, use ONLY a fuse of identical size. With power to the unit disconnected, check all electrical connec- t ...

  • Bryant A93040 - page 9

    g. Manually close blower access panel door switch. Use a piece of tape to hold switch closed. WARNING: Blower access panel door switch opens 115-v power to control center. No component operation can occur. Caution must be taken when manually closing this switch for service purposes. Failure to follow this warning could result in personal injury or ...

  • Bryant A93040 - page 10

    (1.) Release blower access panel door switch and turn setup switch SW-6 to OFF position. (2.) Replace blower access panel. (3.) Operate furnace through 1 heat cycle to check for proper operation and check LED status. (4.) If furnace is operating properly and LEDs indicate proper operation, replace main furnace door. IX. CHECKING HEAT TAPE OPERATION ...

  • Bryant A93040 - page 11

    Fig. 13—Inducer Housing Drain Tube A94208 ...

  • Bryant A93040 - page 12

    EACH OF THE FOLLOWING STATUS CODES IS A TWO DIGIT NUMBER WITH THE FIRST DIG IT DETERMINED BY NUMBER OF FLASHES OF THE YELLOW LED AND THE SECOND DIGIT DETERMINED BY NUMBER OF FLASHES OF THE GREEN LED. RED LED1 ON Furnace is operating in emergency heat. RED LED2 ON The microprocessor has malfunctioned. To reset: Put setup switch " SW-1 " in ...

  • Bryant A93040 - page 13

    Fig. 15—Service Label A93305 To initiate t he component test sequence, shut "OFF" the room thermostat o r disconnect th e "R" thermostat lead. Put setup switch "SW-6" in the "ON" po sition to start the compon ent test sequence . Once initiated the main board will t urn "ON" the inducer motor-low s ...

  • Bryant A93040 - page 14

    → Fig. 16—Wiring Diagram A98305 FRS LS ALS FSE GV C M P HI NOT E #3 3 PL1 PL7 12 1 0 4 6 12 ORN BRN YEL GRN BLK WHT 3 PL 9 HS I 12 1. 5 A MP EAC1 EAC2 2 1 PL4 1 2 3 7 8 4 5 6 YEL ORN BRN GR N BLU BRN RED 10 11 B2 RED 9 5 PL3 5BL U 4YEL 3VIO 2ORN 1RE D RE D ORN VIO YEL BLU WHT BLK RED ORN VIO YEL BLU 98 765432 1 PL10 1 PL 11 5 IND. NOT E #7 PL11 ...

  • Bryant A93040 - page 15

    A94328 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:  • Unit Familiarization • Maintenance  • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is availa ...

  • Bryant A93040 - page 16

    © 1998 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 —16— Printed in U.S.A. sp0539 Catalog No. 5335-505 ...

メーカー Bryant カテゴリー Furnace

Bryant A93040のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- A93040の取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant A93040の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant A93040の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant A93040の取り付け説明書、サービスマニュアル、簡易説明書、またはBryant A93040のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant A93040の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant A93040デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant A93040を使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant A93040ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant A93040の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant A93040の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant A93040に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant A93040デバイスの基本機能を使うにあたってのヒント。 Bryant A93040のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant A93040に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant A93040のメーカー/サービスへの連絡先に関する情報。

Bryant A93040についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant A93040の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant A93040で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)