Pelco 90の取扱説明書

24ページ 0.72 mb
ダウンロード

ページに移動 of 24

Summary
  • Pelco 90 - page 1

    INST ALLA TION 090 Series Camclosure ® Indoor Integrated Camera System C2462M-D (3/08) Surface Mount/In-Ceiling ...

  • Pelco 90 - page 2

    ...

  • Pelco 90 - page 3

    C2462M-D (3/08) 3 Contents Important Safety Instructi ons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Descripti ...

  • Pelco 90 - page 4

    4 C2462M-D (3/08) List of Illustrations 1 How to Remove the Dome Bubble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 Ceiling/W all In stallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3 Concrete Ceiling/W a ...

  • Pelco 90 - page 5

    C2462M-D (3/08) 5 Important Safety Instructions 1. Installation and servicing should be d one only by qualified se rvice personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and mois ...

  • Pelco 90 - page 6

    6 C2462M-D (3/08) Description The ICS090 Series Camclosure ® integrated camera system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted or recessed to the surface of a ceiling or wall. Prior to the installation of your n ew system, thoroughly familiarize yourself with the information i ...

  • Pelco 90 - page 7

    C2462M-D (3/08) 7 Remove the Dome Bubble T urn the dome bubble counterclockwise and lift (refer to Figure 1). Place the b ubble on a nonabrasive surface. If the unit is supplied with a dome liner , remove the li ner b efore installing the un it. T o re move the liner , gently lift it from the unit. Place t he liner to the side; it will be rein stal ...

  • Pelco 90 - page 8

    8 C2462M-D (3/08) Install the Back Box The installation methods for the ICS090 Series include the following options: • Mount to the surface of a ceiling or wall • Install in a suspended ceiling • Install in a fixed ceiling or wall • Mount to the surface of a 4S standard electrical bo x • Install in a 4S deep electrica l box Select the bes ...

  • Pelco 90 - page 9

    C2462M-D (3/08) 9 4. Use the 6-32 toggle bolts (not supplied) to at tach the surfa ce mount ring and back box to the mounting surface, refer to Figure 2. NOTE: For a concrete ceiling/wall installation, use 8-32 mounting hardware (not suppl ie d), refer to Figure 3. Figure 2. Ceiling/Wall Installati on Figure 3. Concrete Ceiling/W all Installation ...

  • Pelco 90 - page 10

    10 C2462M-D (3/08) IN-CEILING INSTALLATION: SUSPENDED CEILING Refer to Figure 4 and complete the following steps. 1. Remove the ceiling tile from the ceiling. 2. Cut a 4-inch diameter h ole in the ceiling tile. 3. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circul ...

  • Pelco 90 - page 11

    C2462M-D (3/08) 11 Figure 5. How to Remove Surfac e Mount Ring from Back Box AC operation only: If you are wiring more than one ICS090 Camclosure to the same transformer , connect one side of the transformer to the red wire on all units, and then connect the other side of the transformer to the black wire on all units. Failure to connect all of the ...

  • Pelco 90 - page 12

    12 C2462M-D (3/08) IN-CEILING INSTALLATION: FIXED CEILING/W ALL Refer to Figure 6 and complete the following steps. 1. Cut a 4-inch diameter h ole in the ceiling/wall. 2. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks loca ted on the sides of the surfa ...

  • Pelco 90 - page 13

    C2462M-D (3/08) 13 INSTALLATION TO THE SURF ACE OF A 4S STANDARD ELECTRICAL BOX Refer to Figure 7 and complete the following steps. 1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (s upplied). 2. Connect the video cable/wires. BNC: Connect the BNC connector from the Camclosure to a mating BNC connector . T wisted pair: ...

  • Pelco 90 - page 14

    14 C2462M-D (3/08) INSTALLATION IN A 4S DEEP ELECTRICAL BOX Refer to Figure 8 and complete the following steps. 1. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks loca ted on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove th ...

  • Pelco 90 - page 15

    C2462M-D (3/08) 15 Camera Positioning Manually rotate and tilt th e camera module to positio n the camera. Do not over- rotate the module. Figure 9. Positioning the Camera WAR NI NG : Excessively turning the module in one direct ion could result in damage to the wiring.    ì T ilt 140° î Pan 360° ï Rotation 360° ...

  • Pelco 90 - page 16

    16 C2462M-D (3/08) Camera Adjustments SWITCH SETTINGS SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS Refer to the switch drawing. The switch is located n ext to the lens. Automatic backlight compensation (factory setting) is used under vary ing lighting conditions (suc h as ou tdoors) or fixed lighting conditions where there are no b ...

  • Pelco 90 - page 17

    C2462M-D (3/08) 17 V ERTICAL PHASE ADJUSTMENT (24 V AC OPERATION ONLY) When using more than one camera power supply, a brief vertical roll may occur on the monitor when a camera view is switched. T o elim inate vertical roll, reverse the 24 V AC connections on one camera. If both cameras are connected to the same transformer , this should solve the ...

  • Pelco 90 - page 18

    18 C2462M-D (3/08) Reinstall the Dome Bubble DOME LINER INSTALLATION If the unit is supplied with a dome liner , reinsta ll t he liner before installing the dome bubb le. T o install the liner , refer to Figure 11 comp lete the following steps: 1. Align the studs located on the camera module with the clips on the liner . 2. Lightly pinch the sides ...

  • Pelco 90 - page 19

    C2462M-D (3/08) 19 DOME BUBBLE INSTALLATION T o insta ll the dome bubble refer t o Figure 12 and complete the fo llowing steps: 1. Select the bubble (clear or smoked). 2. Align the standoffs of the bubble with the slots of the back box. 3. T urn the bubble clockwise, until it locks in place. Figure 12. Installing the Dome Bubble ...

  • Pelco 90 - page 20

    20 C2462M-D (3/08) Service Connector An optional 4-foot service/monitor cable, part numb er ICS090-SC, is available for on- site setup and adjustments. T o use the cable simply plug one end of the cable directly into the service connector of the ICS090, and then connect the other end to any st andard BNC (VIDEO IN) connector on a monitor . T o asse ...

  • Pelco 90 - page 21

    C2462M-D (3/08) 21 Specifications BACKBOX Electrical Input V oltage 12 VDC or 24 V AC (±10%), autosensing Power Consumption 3 W or less Video Connector BNC General Pan/T ilt Adjustment Pan 360° T ilt 140° (20° to 160° range) Rotation 360° Construction Back Box and Surface Mount Ring ABS plastic Bubble Polycarbonate Finish White Environment In ...

  • Pelco 90 - page 22

    22 C2462M-D (3/08) The materials used in the manufacture of this document an d its components are compliant to th e requirements of Directiv e 2002/95/EC. This equipment co ntains electr ical or electron ic components that must be recycle d properly to comply with Direct ive 2002/96/EC of the European Union re garding the disp osal of waste electri ...

  • Pelco 90 - page 23

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, witho ut charge, any mer c handise proved defective in ma terial or wo rkmanship for a period of one year after th e date of shipment. Exception s to this warrant y are as noted below: • Five years on fiber opt ic products and TW3 000 Series unshield ed twisted pair (U ...

  • Pelco 90 - page 24

    Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Finland | France | Germany | Italy | Macau | The Nethe rland s | Russia | Singapore South Africa | Spain | Sweden | United Arab Emirates ...

メーカー Pelco カテゴリー Security Camera

Pelco 90のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 90の取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco 90の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco 90の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco 90の取り付け説明書、サービスマニュアル、簡易説明書、またはPelco 90のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco 90の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco 90デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco 90を使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco 90ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco 90の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco 90の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco 90に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco 90デバイスの基本機能を使うにあたってのヒント。 Pelco 90のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco 90に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco 90のメーカー/サービスへの連絡先に関する情報。

Pelco 90についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco 90の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco 90で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)