    BSC 7107 DC Brushless Control Installation and Operating Manual 9/97 MN1231 ...

  • Baldor BSC 7107 DC - page 2

    T able of Contents T able of Contents i Section 1 General Information 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Limited W arranty 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety Notice 1-3 . . . . . . . . . . . . ...

  • Baldor BSC 7107 DC - page 3

    ii T able of Contents ...

  • Baldor BSC 7107 DC - page 4

    Section 1 General Information General Information 1-1 Introduction Baldor Series BSC 7107 control is a general purpose brushless DC motor control. This control commutates power into standard 3-phase brushless (BLDC) motors. The control input line voltage is 120 V AC ± 10%. This control provides up to 7 amperes of continuous current to the motor . ...

  • Baldor BSC 7107 DC - page 5

    1-2 General Information Limited W arranty Fo r a period of one (1) year from the date of original purchase, BALDOR will repair or replace without charge controls and accessories which our examination proves to be defective in material or workmanship. This warranty is valid if the unit has not been tampered with by unauthorized persons, misused, abu ...

  • Baldor BSC 7107 DC - page 6

    General Information 1-3 Safety Notice This equipment contains voltages that may be as great as 1000 volts! Electrical shock can cause serious or fatal injury . Only qualified personnel should attempt the start-up procedure or troubleshoot this equipment. This equipment may be connected to other machines that have rotating parts or parts that are dr ...

  • Baldor BSC 7107 DC - page 7

    1-4 General Information W ARNING: Be sure the system is properly grounded before applying power . Do not apply AC power before you ensure that all grounding instructions have been followed. Electrical shock can cause serious or fatal injury . W ARNING: Do not remove cover for at least five (5) minutes after AC power is disconnected to allow capacit ...

  • Baldor BSC 7107 DC - page 8

    Section 2 Receiving & Installation Receiving & Installation 2-1 Receiving The control is thoroughly tested at the factory and carefully packaged for shipment. When you receive your control, there are several things you should do immediately . 1. Observe the condition of the shipping container and report any damage immediately to the commerc ...

  • Baldor BSC 7107 DC - page 9

    2-2 Receiving & Installation Figure 2-1 Mounting Diagram 6.70 9.00 7.50 6.30 0.20 7 / 32 dia. (4 places) 2.90 T op View End V iew AC Power Connection Refer to Figure 2-2. A fused 120 V AC power source is required. A 12 AMP fuse should be used. 1. Be sure the AC source is disconnected (OFF). 2. Be sure the appropriate fuse is installed at the so ...

  • Baldor BSC 7107 DC - page 10

    Receiving & Installation 2-3 Figure 2-2 Control Connection Locations P4 Upper Board P1 GND (Connect to plant “Earth” ground). AC Line BLDC Motor Connection s. Scaled motor current test point. 1 10mV = 1A Motor Current. 60 ° / 120 ° Jumper 120 ° 60 ° Lower Board T erminal tightening torque = 4 Lb-in (0.45 Nm) (Black) (Red) + Hall 10K 10K ...

  • Baldor BSC 7107 DC - page 11

    2-4 Receiving & Installation Sensor and Motor Connections Refer to Figure 2-2. Brushless DC motors have eleven (1 1) wires: three (3) motor phase power wires, three (3) hall sensor wires, two (2) wires for hall sensor power and sensor common, one (1) wire for motor ground and two (2) wires for motor thermal switch. Note: Baldor BLDC motors have ...

  • Baldor BSC 7107 DC - page 12

    Receiving & Installation 2-5 Reverse Operation T erminal P4–REV is the forward/reverse control. Y ou can reverse motor direction by connecting P4–REV to P4–COM. Use a jumper wire, switch, relay , or an open collector NPN transistor . Caution: Before reversing directions, make sure the motor is stopped. This control is not designed for plu ...

  • Baldor BSC 7107 DC - page 13

    2-6 Receiving & Installation 1st Time Power Up Procedure (or after a motor is replaced) Caution: If full AC V oltage is applied and the motor connections are wrong, the control will be damaged. Apply 10% of the input voltage to test motor lead connections at the first time power up or after a motor is replaced. It is strongly recommended that a ...

  • Baldor BSC 7107 DC - page 14

    Section 3 Adjustments Adjustments 3-1 Current Limit Adjustment The current limit adjustment is factory set at 10 AMPS and you should not have to increase this setting for the Series BSC 7107 control. Rotating the I Limit potentiometer on the upper board CCW decreases the current limit. T o calculate motor current, refer to Figure 2-2 and measure th ...

  • Baldor BSC 7107 DC - page 15

    3-2 Adjustments Minimum Speed Adjustment 1. Set the Speed Pot to zero speed (fully CCW). 2. Set the MIN pot on the upper board (Figure 2-2) fully CCW . 3. Apply power to the control. 4. Slowly rotate the MIN CW until the motor begins to rotate. Then turn the pot CCW until the motor just stops. The control will now run with a near–zero deadband. 5 ...

  • Baldor BSC 7107 DC - page 16

    Section 4 Specifications and Data Specifications 4-1 Specifications Input V oltage 120 V AC ± 10% . . . . . . . . . . . . . . . . . . . . . Output V oltage (Filtered Output) 0 to 140 VDC . . . . . Load Current (Continuous) 7 Amperes . . . . . . . . . . . . . Overload Current 150% for 30 seconds . . . . . . . . . . . . . Speed Range 50:1 . . . . . ...

  • Baldor BSC 7107 DC - page 17

    4-2 Specifications Hall Signal Timing Diagram S1 (White) S2 (Y ellow) S3 (Orange) 0 0 0 15 30 60 30 60 120 45 60 90 60 120 240 75 150 300 90 180 360 105 210 420 120 240 480 135 270 540 150 300 600 165 330 660 180 360 720 Ć 8 Pole Mechanical Degrees Ć 4 Pole Mechanical Degrees Ć Electrical Degrees Hall Sensor Leads ( Hall generated signal) Brushl ...

  • Baldor BSC 7107 DC - page 18

    BALDOR ELECTRIC COMP ANY P .O. Box 2400 Fort Smith, AR 72902–2400 (479) 646–471 1 Fax (479) 648–5792 © Baldor Electric Company Printed in USA MN1231 9/97 PS50 ...

メーカー Baldor カテゴリー Outboard Motor

Baldor BSC 7107 DCのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BSC 7107 DCの取扱説明書
- Baldorの製品カード
- パンフレット
- またはBaldor BSC 7107 DCの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Baldor BSC 7107 DCの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Baldor BSC 7107 DCの取り付け説明書、サービスマニュアル、簡易説明書、またはBaldor BSC 7107 DCのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Baldor BSC 7107 DCの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Baldor BSC 7107 DCデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBaldor BSC 7107 DCを使用するのを助ける技術的文書のことです。説明書は通常、全てのBaldor BSC 7107 DCユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Baldorの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Baldor BSC 7107 DCの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBaldor BSC 7107 DCの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Baldor BSC 7107 DCに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Baldor BSC 7107 DCデバイスの基本機能を使うにあたってのヒント。 Baldor BSC 7107 DCのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Baldor BSC 7107 DCに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBaldor BSC 7107 DCのメーカー/サービスへの連絡先に関する情報。

Baldor BSC 7107 DCについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBaldor BSC 7107 DCの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBaldor BSC 7107 DCで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)