    TECHNICAL GUIDE AFFINITY SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R-410A MODELS: CZB018 THRU 060 (1.5 THRU 5 NOMINAL TONS ) Due to continuous pr od uct improvement, sp eci fications are subject to change without n otice. Visit us on the web at www .yor k.com Additional rating informa tion can be foun d at www .ari.or g/aridirector y LISTED ISO 90 ...

  • York CZB018 THRU 060 - page 2

    246723-YTG-J-1006 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. PHYSICAL AND ELECTRICAL DA T A MODEL CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Unit Supply V oltage 208-230V , 1 φ, 60Hz Normal V oltage Range 1 187 to ...

  • York CZB018 THRU 060 - page 3

    246723-YTG-J-1006 Unitary Products Group 3 Additional R-410A Charge / TXV Size f or V arious Matche d Sy stems Out door Unit CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Unit Orifice (s) 1 TVM901 1 TVM903 1 T VM903 1 TVM903 1 TVM904 1T V M 4 C 1 1 T VM905 1 TVM905 Factory R-410A Charge, lbs- oz 5-13 6-4 7-4 6-4 8-13 8-12 ...

  • York CZB018 THRU 060 - page 4

    246723-YTG-J-1006 4 Unitary Products Group PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrig erant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing. 2. V erify the TXV and additional char ge required for specific evaporator coil in th e system using the above table. 3. Additional ...

  • York CZB018 THRU 060 - page 5

    246723-YTG-J-1006 Unitary Products Group 5 COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL ELECTRIC HEA T KW 2 W RA TED CFM NET MBH SEER EER TOT AL SENS. 1 PH 13 SEER AC WITH MA CZB0181 1 MA08B 2,5,8,10 17 FC/MC18B 600 18.0 12.1 13.00 1 1.00 MA08B 2,5,8,10 17 FC/MC24B 600 18.0 12.1 13.00 1 1.00 MA08B 2,5 ...

  • York CZB018 THRU 060 - page 6

    246723-YTG-J-1006 6 Unitary Products Group 1 PH 13 SEER AC WITH AHP/ SHP / F*FP CZB0181 1 AHP18 2,5,8 17 – 600 18.0 12.1 13.00 1 1.00 AHP24 2,5,8,10 17 – 600 18.0 12.3 13.00 1 1.00 F*FP024 5,8,1 0 17 – 600 18.0 12.1 13.00 1 1.00 CZB0241 1 AHP24 2,5,8,10 17 – 800 23.0 16.9 13.00 1 1.00 F*FP030 5,8,10,15 17 – 800 23.0 16.7 13.00 1 1.00 CZB0 ...

  • York CZB018 THRU 060 - page 7

    246723-YTG-J-1006 Unitary Products Group 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER 1,2 EER TOT AL SENS. CZB0181 1 450 750 14,17 FC/MC/PC/UC18 600 18.0 12.1 13.00 1 1.00 14,17 FC/MC/PC/UC24 600 18.0 12.1 13.00 1 1.00 14,17 FC/MC/ ...

  • York CZB018 THRU 060 - page 8

    246723-YTG-J-1006 8 Unitary Products Group COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER EER T OTAL SENS. 1 PH 13 SEER AC WITH V ARIABLE SPEED FURNACES 2 CZB0181 1 PV8*A12 FC/MC/PC24A 14 600 18.0 12.2 14.00 1 1.50 PV9*A12 FC/MC/PC24A 14 600 18.0 12.2 14.0 ...

  • York CZB018 THRU 060 - page 9

    246723-YTG-J-1006 Unitary Products Group 9 CZB0421 1 PV8*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*D20 FC/MC/PC48D 24 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 HC60 21 1400 40.5 29.8 1 ...

  • York CZB018 THRU 060 - page 10

    246723-YTG-J-1006 10 Unitary Products Group ACCESSORIES* Hard St art Kit (024-31994-000, 024-319 95-000) - Provides increased starting torque for areas w ith low voltage. TXV Kits - 1 TV09 series thermal exp ans ion valves precisely meter refrigerant for optimum performance Low Ambient Pressure Switch Kit (2LA 06700424) - Allows use of air conditio ...

  • York CZB018 THRU 060 - page 11

    246723-YTG-J-1006 Unitary Products Group 11 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 12

    246723-YTG-J-1006 12 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 13

    246723-YTG-J-1006 Unitary Products Group 13 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 14

    246723-YTG-J-1006 14 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 15

    246723-YTG-J-1006 Unitary Products Group 15 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 16

    246723-YTG-J-1006 16 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 17

    246723-YTG-J-1006 Unitary Products Group 17 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 18

    246723-YTG-J-1006 18 Unitary Products Group NOTES ...

  • York CZB018 THRU 060 - page 19

    246723-YTG-J-1006 Unitary Products Group 19 NOTES ...

  • York CZB018 THRU 060 - page 20

    Subject to change without notice. Printe d in U.S.A. 246723-YTG-J-1006 Copyright © by York International/JCI 2006. All righ ts reserved. Supersedes: 246723-YTG-H-0906 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 NOTES ...

メーカー York カテゴリー Air Conditioner

York CZB018 THRU 060のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CZB018 THRU 060の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork CZB018 THRU 060の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York CZB018 THRU 060の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York CZB018 THRU 060の取り付け説明書、サービスマニュアル、簡易説明書、またはYork CZB018 THRU 060のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York CZB018 THRU 060の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York CZB018 THRU 060デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork CZB018 THRU 060を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork CZB018 THRU 060ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York CZB018 THRU 060の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork CZB018 THRU 060の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York CZB018 THRU 060に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York CZB018 THRU 060デバイスの基本機能を使うにあたってのヒント。 York CZB018 THRU 060のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York CZB018 THRU 060に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork CZB018 THRU 060のメーカー/サービスへの連絡先に関する情報。

York CZB018 THRU 060についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork CZB018 THRU 060の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork CZB018 THRU 060で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)