    GENERAL Y ORK Model B CH units are single package heat pumps des igne d for outd oor in stal lati on on a roof top o r a s lab. Supp leme ntal el ectr i c hea ters a re available as field- instal led access ories . The un its a re c ompl etely a ss embled o n ri gid, per man entl y atta ched ba se rail s. All pi ping, refrigeran t charg e, and e le ...

  • York 2000 - page 2

    Gene ral ..... ...... ...... .... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 1 Inspe ction ...... ...... ...... ...... ...... ...... ...... .... ...... ...... ...... ...... ...... . 1 Referen ce ... ...... .... .... .... .... .... ...... .... .... .... .... ...... .... .... .... .... .... 1 App rovals ..... .... .... .... ...

  • York 2000 - page 3

    These unit s must be inst alled i n acco rdanc e with th e cur rent edi tion of th e followin g na tion al a nd l ocal safety c od es: In U .S.A.: 1. Nat ional Ele ctrical Code ANSI /NFP A No . 70. 2. Lo cal elec tri c ut il it y req ui remen ts . In Ca nada: 1. Cana dian Elec tr i ca l C ode C 22 .1 2. Canad ian Installati on Codes CAN/CGA-B1 49.1 ...

  • York 2000 - page 4

    casi ng. Outdoo r d uctwor k mu st b e in sulate d an d water - proof ed. Ref er to Figure 6 f or inf ormation con cerning side and bo ttom supply and re turn air duc t open ings . FIL TERS 1" fil ter s are s uppl ied wi th ea ch un it. 2" re plac emen t fil ters m ay be used with no m odific ation t o the filter rac ks. Filt ers must alw ...

  • York 2000 - page 5

    ELECT RIC HEA TERS Supp leme ntal el ectr i c hea ters may be ordered as a field -in stal led a cces sor y . Ref er to Form 530.18-N7.1V for inst allation instruction . These UL and C .G.A. approv ed he aters are lo cate d withi n the ce ntra l comp ar tment of the unit (se e Figure 6 f or access panel) wi th the heati ng elements e xtendi ng into ...

  • York 2000 - page 6

    OPTIONAL ECONO MIZER RAIN HOOD The followin g pr oc ed ur e sh ou ld be us ed when ass em bling an econom izer r ain hood onto a unit. Ref er to Figure 4. The outdoo r and return ai r dampers , dampe r actuat or , the lin kage and a ll the co ntrol s ar e factor y m ount ed as pa r t of the ec onom izer option . All of the h ood c ompone nt s, incl ...

  • York 2000 - page 7

    FIG. 5 - ENTHALPY SET POIN T ADJ U STMENT WEIGHTS (LBS) Basic Unit 3 T on 555 4 T on 595 5 T on 620 OPTIONS / ACCESSORIES Electric Heat (Nominal KW ) 5 - 7 KW 18 10 - 15 KW 23 20 - 30 KW 28 Economiz er 50 Belt-D rive Blower 5 Motorized Outdoor Air Damper 26 Bar ometri c Re lief /Fix ed Outdoor Air Intake Damper 10 Roof Mounting Curb 92 MODELS BCH 0 ...

  • York 2000 - page 8

    DUCT CO VERS - Units are shipped with all air duct openings cov ered. Fo r side duct applications; 1.Remov e and discard t he supply and retur n air duct covers. 2.Connect ductwork to duct flanges on the rear of the u nit. Fo r bott om duct applications; 1. Remove the si de supply air duct cov er to gain access t o the bottom supply air knock out p ...

  • York 2000 - page 9

    T ABLE 4 - SUPPL Y AIR PERFOR MANCE - 3 & 4 T on Units w/Belt-Dr ive Blo wer MODE L BCH AIR FLOW CFM A vai lab le External Static Pressure - I WG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM W atts RPM Watts RPM W atts RPM W atts RPM W atts RPM W atts RPM W atts 036 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 ...

  • York 2000 - page 10

    T ABLE 5 - SUPPL Y A IR PERFORMANCE - 5 T on w/Belt-Driv e Blo wer MODE L BHN AIR FLOW CFM A vai lab le External Static Pressure - I WG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM W atts RPM Watts RPM W atts RPM W atts RPM W atts RPM W atts RPM W atts 060 2500 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 1181 1720 2400 1032 1405 1054 147 ...

  • York 2000 - page 11

    MODE L BLOWER RANGE (RPM) MO TO R* ADJUST ABLE MO T OR PULLEY FIXED BLO WER PULLEY BEL T HP RPM FRAME SIZE SERVICE FA C T O R PITCH DIA. (in.) BORE (in.) PITCH DIA. (in.) BORE (in.) PITCH LENGTH (in.) DESIG- NA T ION BCH 036 790 - 1120 1-1/2 1725 56 1.15 2.4 - 3.4 7/8 5.7 1 37.3 A36 BCH 048 790 - 1120 1-1/2 1725 56 1.15 2.4 - 3.4 7/8 5.7 1 37.3 A36 ...

  • York 2000 - page 12

    COOL ING SY STEM The u nit has an air-co oled conden ser and is f a ctor y-char ged with Re fr ige rant -22. The compressor is her metically sealed, internally sprung, mou nted on spr ing isolator s and inherently (inter nally) prote cted. If the re is an abno r mal temp erature rise in the compressor , the protector will op en to sh ut do wn the c ...

  • York 2000 - page 13

    LOCK OUT CONTR OL Any one of f our con dition s will put th e system into a loc k-out condit ion du ring th e he atin g or co ol in g mo de: 1. The disc harge li ne temp erat ure reach es 255 ° F (215 ° F reset) o r , 2. Th e discha rge pressu re reaches 39 8 PSIG (310 PSI G reset) o r , 3. The suct ion li ne fr ee z e st at equal s 26 ° F (38 ? ...

  • York 2000 - page 14

    W ARNING : F ailure to properly ad just th e total system air qu an- tity c an resu lt in poor sy stem p erf ormance. After readin gs hav e been obta ined, remo ve the tu bes and seal the dril led hol es in the s ide pan els. 5/16" dot plugs (P/ N 029- 1388 0) are av ailable through nor mal par ts order ing proc edur es. N O T E : DE-ENERGIZ E ...

  • York 2000 - page 15

    511.06-N5Y Unitar y Products Group 15 ...

  • York 2000 - page 16

    Unitary Products Group 5005 Y ork Drive, N o rman, Oklaho ma 73 06 9 Subj ect to c han ge w itho ut n otic e. Prin ted in U.S.A. Copyright  by Y ork Internation al Corporation 2000 . All Rights Reserved. 511. 06-N5Y 208/ 230/46 0 VO L T MODELS ONL Y 208/23 0/57 5 VOL T MODELS ONL Y ...

メーカー York カテゴリー Air Conditioner

York 2000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 2000の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork 2000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York 2000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York 2000の取り付け説明書、サービスマニュアル、簡易説明書、またはYork 2000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York 2000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York 2000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork 2000を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork 2000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York 2000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork 2000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York 2000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York 2000デバイスの基本機能を使うにあたってのヒント。 York 2000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York 2000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork 2000のメーカー/サービスへの連絡先に関する情報。

York 2000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork 2000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork 2000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)