Keating Of Chicago MG-2 - page 1
MG-2/MG-4 GAS HO T PLA TE SER VICE MANU AL KEEP THIS MANU AL FOR TRAINING NEW PERSONNEL 1-800-KEA TING www .keatingofchicago.com Hot Plate 0107 09/07 ...
-
Keating Of Chicago MG-2 - page 2
SECTION I INTRODUCTION General Information . . . . . . . . . . . . . . . . . . . . . . . . .1 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 S tandard Features . . . . . . . . . . . . . . . . . . . . . . . . . .1 Model V ariations . . . . . ...
-
Keating Of Chicago MG-2 - page 3
POST THIS LABEL IN A PR OMINENT L OCA TION ON Y OUR UNIT i IMPOR T ANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS A T MAIN SHUT OFF V AL VE AND CONT ACT THE LOCAL GAS COMP ANY OR GAS SUPPLIER FOR SERVICE. FOR Y OUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. IMP ...
-
Keating Of Chicago MG-2 - page 4
I INTRODUCTION GENERAL Keating MG-2 and MG-4 Hot Plates are designed to give maximum production efficiency; delivering high quality food products. The following design features are incorporated in all Keating Hot Plates. ST ANDARD FEA TURES Highly polished stainless steel front Infinite controls 12" working height Gas and air a ...
-
Keating Of Chicago MG-2 - page 5
2 THIS HOT PLA TE MA Y NOT BE AL TERED, MODIFIED OR CHANGED IN ANY W A Y . The S tate of California enacted the California Safe drinking water and T oxic Enforcement Act of 1986, (Prop.65), which “prohibits any person in the course of doing business from knowingly and intentionally exposing any individual to a chemical known to the S tate of ...
-
Keating Of Chicago MG-2 - page 6
testing at test pressures less than to equal to 1/2 psig (3.45 KP A), hot plate must be isolated from gas supply piping. When pressure testing at test pressures above 1/2 psig (3,45 KP A), hot plate must be disconnected from gas supply piping system. POSITIONING The hot plate must be no closer than 6" from any combustible material and 16" ...
-
Keating Of Chicago MG-2 - page 7
4 W ARNING PROP ANE GAS MA Y EVENTUALL Y LOSE ITS ODOR AND PRECAUTIONS SHOULD BE T AKEN TO ASSURE THA T IT IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR. IF THERE IS ANY DOUBT , YOU SHOULD CALL YOUR LOCAL PROP ANE GAS SUPPLIER FOR ASSIST ANCE. III OPERA TING LIGHTING Keating hot plates are designed to provide maximum efficiency and deliver h ...
-
Keating Of Chicago MG-2 - page 8
V SER VICE DIAGNOSIS On constant pilot models, the pilot light will be between 3/8" to 1/2" high and burn clear blue. The constant pilot consumes about 180 BTU/hr . of gas and is used to ignite the burners. A. T rouble Shooting The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends tha ...
-
Keating Of Chicago MG-2 - page 9
6 GAS HOT PLA TE P ARTS LIST P ART ITEM DESCRIPTION MG-2 MG-4 NUMBER 1 GAS V AL VE (INFINITE CONTROL) WITH NG ORIFICE #49 CONST ANT PILOT 2 4 002666 SP ARK IGNITOR 2 4 002666 ORIFICE, HOODED, NA TURAL GAS, #49 2 4 002676 GAS V AL VE (INFINITE CONTROL) WITH PROP ANE ORIFICE #53 CONST ANT PILOT 2 4 002666 SP ARK IGNITOR 2 4 002666 ORIFICE, HOODED, PR ...
-
Keating Of Chicago MG-2 - page 10
7 HOT PLA TE ASSEMBL Y NOTE: MG-4 hot plates are built as two MG-2 hot plates side by side. The MG-2 is shown here. NOTE: Part numbers correspond with the Hot Plate Parts list on p age 9. ...
-
Keating Of Chicago MG-2 - page 11
8 VIII WIRING DIAGRAMS MG SI WIRING AND LADDER DIAGRAMS The diagrams below apply to hot plates with spark ignition (“SI”). Hot plates with const ant pilots (“CP”) do not have any electrical connections. NOTE: MG-4 hot plates are essentially two MG-2 hot plates side by side. Each cabinet half has its own spark module, electrode and ignitor s ...
-
Keating Of Chicago MG-2 - page 12
L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp ® , Custom Pasta Systems, T op-Side™ Cookers, Computer T imers, Fryer & Pasta V essels, and Keating replacement parts ("products") installed after J ...
-
Keating Of Chicago MG-2 - page 13
SER VICE INFORMA TION If you have a service related question call 1-800-KEA TING . Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEA TING OF CHICAGO, INC. 8901 W . 50th Street, McCook, Illinois 60525-600 1 Phone: (708) 246-3000 F AX: (708) 2 ...