    MG-2/MG-4 GAS HO T PLA TE SER VICE MANU AL KEEP THIS MANU AL FOR TRAINING NEW PERSONNEL 1-800-KEA TING www .keatingofchicago.com Hot Plate 0107 09/07 ...

  • Keating Of Chicago MG-2 - page 2

    SECTION I INTRODUCTION General Information . . . . . . . . . . . . . . . . . . . . . . . . .1 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 S tandard Features . . . . . . . . . . . . . . . . . . . . . . . . . .1 Model V ariations . . . . . ...

  • Keating Of Chicago MG-2 - page 3

    POST THIS LABEL IN A PR OMINENT L OCA TION ON Y OUR UNIT i IMPOR T ANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS A T MAIN SHUT OFF V AL VE AND CONT ACT THE LOCAL GAS COMP ANY OR GAS SUPPLIER FOR SERVICE. FOR Y OUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. IMP ...

  • Keating Of Chicago MG-2 - page 4

    I INTRODUCTION GENERAL Keating MG-2 and MG-4 Hot Plates are designed to give maximum production efficiency; delivering high quality food products. The following design features are incorporated in all Keating Hot Plates. ST ANDARD FEA TURES  Highly polished stainless steel front  Infinite controls  12" working height  Gas and air a ...

  • Keating Of Chicago MG-2 - page 5

    2  THIS HOT PLA TE MA Y NOT BE AL TERED, MODIFIED OR CHANGED IN ANY W A Y . The S tate of California enacted the California Safe drinking water and T oxic Enforcement Act of 1986, (Prop.65), which “prohibits any person in the course of doing business from knowingly and intentionally exposing any individual to a chemical known to the S tate of ...

  • Keating Of Chicago MG-2 - page 6

    testing at test pressures less than to equal to 1/2 psig (3.45 KP A), hot plate must be isolated from gas supply piping. When pressure testing at test pressures above 1/2 psig (3,45 KP A), hot plate must be disconnected from gas supply piping system. POSITIONING The hot plate must be no closer than 6" from any combustible material and 16" ...

  • Keating Of Chicago MG-2 - page 7

    4 W ARNING PROP ANE GAS MA Y EVENTUALL Y LOSE ITS ODOR AND PRECAUTIONS SHOULD BE T AKEN TO ASSURE THA T IT IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR. IF THERE IS ANY DOUBT , YOU SHOULD CALL YOUR LOCAL PROP ANE GAS SUPPLIER FOR ASSIST ANCE. III OPERA TING LIGHTING Keating hot plates are designed to provide maximum efficiency and deliver h ...

  • Keating Of Chicago MG-2 - page 8

    V SER VICE DIAGNOSIS  On constant pilot models, the pilot light will be between 3/8" to 1/2" high and burn clear blue. The constant pilot consumes about 180 BTU/hr . of gas and is used to ignite the burners. A. T rouble Shooting The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends tha ...

  • Keating Of Chicago MG-2 - page 9

    6 GAS HOT PLA TE P ARTS LIST P ART ITEM DESCRIPTION MG-2 MG-4 NUMBER 1 GAS V AL VE (INFINITE CONTROL) WITH NG ORIFICE #49 CONST ANT PILOT 2 4 002666 SP ARK IGNITOR 2 4 002666 ORIFICE, HOODED, NA TURAL GAS, #49 2 4 002676 GAS V AL VE (INFINITE CONTROL) WITH PROP ANE ORIFICE #53 CONST ANT PILOT 2 4 002666 SP ARK IGNITOR 2 4 002666 ORIFICE, HOODED, PR ...

  • Keating Of Chicago MG-2 - page 10

    7 HOT PLA TE ASSEMBL Y NOTE: MG-4 hot plates are built as two MG-2 hot plates side by side. The MG-2 is shown here. NOTE: Part numbers correspond with the Hot Plate Parts list on p age 9. ...

  • Keating Of Chicago MG-2 - page 11

    8 VIII WIRING DIAGRAMS MG SI WIRING AND LADDER DIAGRAMS The diagrams below apply to hot plates with spark ignition (“SI”). Hot plates with const ant pilots (“CP”) do not have any electrical connections. NOTE: MG-4 hot plates are essentially two MG-2 hot plates side by side. Each cabinet half has its own spark module, electrode and ignitor s ...

  • Keating Of Chicago MG-2 - page 12

    L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp ® , Custom Pasta Systems, T op-Side™ Cookers, Computer T imers, Fryer & Pasta V essels, and Keating replacement parts ("products") installed after J ...

  • Keating Of Chicago MG-2 - page 13

    SER VICE INFORMA TION If you have a service related question call 1-800-KEA TING . Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEA TING OF CHICAGO, INC. 8901 W . 50th Street, McCook, Illinois 60525-600 1 Phone: (708) 246-3000 F AX: (708) 2 ...

Производитель Keating Of Chicago Категория Food Warmer

Документы, которые мы получаем от производителя устройства Keating Of Chicago MG-2 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Keating Of Chicago
- инструкции обслуживания MG-2
- паспорта изделия Keating Of Chicago
- информационные брошюры
- энергетические этикетки Keating Of Chicago MG-2
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Keating Of Chicago MG-2.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Keating Of Chicago MG-2, инструкции обслуживания, короткие инструкции или инструкции пользователя Keating Of Chicago MG-2. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Keating Of Chicago MG-2.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Keating Of Chicago MG-2, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Keating Of Chicago MG-2 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Keating Of Chicago MG-2.

Полная инструкция обслуживания Keating Of Chicago, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Keating Of Chicago MG-2 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Keating Of Chicago MG-2, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Keating Of Chicago MG-2, которое найдем в данном документе
3. Советы по использованию основных функций устройства Keating Of Chicago MG-2 - которые должны облегчить нам первые шаги во время использования Keating Of Chicago MG-2
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Keating Of Chicago MG-2
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Keating Of Chicago MG-2 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Keating Of Chicago MG-2?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Keating Of Chicago MG-2, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Keating Of Chicago MG-2 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)