Hitachi 222104の取扱説明書

16ページ 0.2 mb
ダウンロード

ページに移動 of 16

Summary
  • Hitachi 222104 - page 1

    Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001 1:1 RA TIO Fast-Ball t Pumps For non–abrasive and non–corrosive oils and lubricants only . 180 psi (1.2 MPa, 12.4 bar) Maximum Air and Fluid Working Pressure Oil Pumps Model No. 222051, Series E Univer ...

  • Hitachi 222104 - page 2

    2 307906 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T roubleshooting 9 . . . . . . . . . . . . . . . . . . . . ...

  • Hitachi 222104 - page 3

    3 307906 TOXIC FLUID HAZARD Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. D Know the specific hazards of the fluid you are using. D Store hazardous fluid in an approved container . Dispose of hazardous fluid according to all local, state and national guidelines. D Al ...

  • Hitachi 222104 - page 4

    4 307906 MOVING P ARTS HAZARD Moving parts can pinch or amputate your fingers or other body parts. D Do not cycle the pump with any parts disassembled. D Keep clear of all moving parts when you start or operate the pump. D Before you service the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpec ...

  • Hitachi 222104 - page 5

    5 307906 Installation F B CD E KEY A Air shutof f valve B Air filter C Air regulator and gauge D Air motor lubricator E Bleed-type master air valve (required, Part No. 1 10223) F Air and fluid hose kits G Ground wire (required, Part No. 22201 1) H Fluid shutoff valve Main Air Line Main Fluid Line A A G G H J K L M J W all bracket K Universal pump ( ...

  • Hitachi 222104 - page 6

    6 307906 Installation Grounding Proper grounding is an essential part of maintaining a safe system. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of this equipment: D Pump: Use a ground wire and clamp as shown i ...

  • Hitachi 222104 - page 7

    7 307906 Installation D Wall Bracket: Use the wall bracket (J) for wall mounting the Universal pump. This wall bracket is sized to fit any Graco pump designed to use a 2-in. bung adapter . Order Part No. 203987. D Runaway V alve: Install a pump runaway valve to shut off the air to the pump when the pump acceler- ates beyond the pre-adjusted setting ...

  • Hitachi 222104 - page 8

    8 307906 Operation Pressure Relief Procedure PRESSURIZED FLUID HAZARD This equipment stays pressurized until pressure is manually relieved. T o reduce the risk of serious injury from moving parts, pressurized fluid, accidental spray from the valve, or splashing fluid, follow this procedure whenever you do any of the following: D Are instructed to r ...

  • Hitachi 222104 - page 9

    9 307906 T roubleshooting Problem Cause Solution Pump does not run. There is no fluid demand. In a closed-end system the pump runs only when there is demand for fluid. Air supply is insufficient. Check air supply . Increase air pressure or volume. Fluid outlet line or intake valve is clogged. Relieve the pressure. Check and clear obstructions. Air ...

  • Hitachi 222104 - page 10

    10 307906 Service NOTE: Clean and inspect all parts for wear or damage when disassembled. Replace parts as needed. Repair Kit 247431 is available. For the best results, use all the parts in the kit. Parts included in the kit are marked with an asterisk in the text, figures, Parts Drawing , and Parts List . Intake V alve See the Parts Drawing on pag ...

  • Hitachi 222104 - page 11

    11 307906 Service 10. Place the ball (18) on the fluid piston (19c). 1 1. Apply thread sealant to the threads of the fluid piston (19), screw the fluid piston onto the piston rod (10), and torque to 23 ft-lb (31.2 N S m). 12. Install the air motor rod assembly by inserting it up through the base from the bottom. 13. Install the spring (8) and the w ...

  • Hitachi 222104 - page 12

    12 307906 Parts List Model 222051, Series E Model 222103, Series E Model 222104, Series E Universal Pump 55-Gallon Drum Bung-Mount Pump 275-Gallon T ank Bung-Mount Pump Includes items 1 through 27 Includes items 1 through 26 Includes items 1 through 26, and 28 through 31, 28 through 30, and 32 Ref. No. Part No. Description Qty . 1 AIR MOTOR (includ ...

  • Hitachi 222104 - page 13

    13 307906 Parts Drawing 2 05944B 3 5 4 6* 7 8 17 9* 10 11 * 12* 13 15 15a* 15b* *16 18 19a 20 21 *22 23 24 *26 28 30 31, 32 1 T orque to 10 to 14 in-lb (1.3 to 1.6 N-m). 1 2 2 3 3 T orque to 95 to 105 ft-lb (129 to 142 N-m). 15d 15e 15f 15c* 15g 4 Lips face up. 5 5 Lips face down. 19b* 19c T orque to 23 ft–lb (31.2 N S m). 4 *1 1 6 Smaller OD up. ...

  • Hitachi 222104 - page 14

    14 307906 Dimensional Drawing 15.7 in. (400 mm) 7.4 in. (187 mm) 36.6 in. (929 mm) Model 222103 1/4 npt(f) 3/4 npt(f) 1 1/2 npt(f) 05940B 46.6 in. (1 183 mm) Model 222104 grounding screw extension tube stand-off T echnical Data Maximum working pressure 180 psi . . . . . . . . . . . . . . . . . (1.2 MPa, 12.4 bar) Fluid pressure ratio 1:1 . . . . . ...

  • Hitachi 222104 - page 15

    15 307906 Performance Curves 0 25 50 75 100 125 150 012345 (3.8) (7.6) (1 1.4) (15.1) (18.9) FLUID FLOW––gpm (lpm) T est Fluid: No. 10 weight oil at 75 _ F (23.9 _ C) T o find fluid outlet pressure at a specific fluid flow and operating air pressure: 1. Locate desired fluid flow along bottom of chart. 2. Follow vertical line up to intersection ...

  • Hitachi 222104 - page 16

    16 307906 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months from th ...

メーカー Hitachi カテゴリー Water Pump

Hitachi 222104のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 222104の取扱説明書
- Hitachiの製品カード
- パンフレット
- またはHitachi 222104の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Hitachi 222104の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Hitachi 222104の取り付け説明書、サービスマニュアル、簡易説明書、またはHitachi 222104のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Hitachi 222104の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Hitachi 222104デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHitachi 222104を使用するのを助ける技術的文書のことです。説明書は通常、全てのHitachi 222104ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Hitachiの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Hitachi 222104の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHitachi 222104の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Hitachi 222104に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Hitachi 222104デバイスの基本機能を使うにあたってのヒント。 Hitachi 222104のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Hitachi 222104に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHitachi 222104のメーカー/サービスへの連絡先に関する情報。

Hitachi 222104についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHitachi 222104の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHitachi 222104で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)