  • Argox AS-8000 - page 2

    NOTICE: This equipment has bee n tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide a reasonable protection ag ainst harmful interface when the equipment is oper ated under a commercial environment. This equipment generates, uses, and can radiate radio frequen ...

  • Argox AS-8000 - page 3

    Using the ArgoxScan 8000 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger . Code scanning is performed along the center of the light bar emitted from the reading window . This bar must cover the entire code. Successful scanning shall be obtained by tilting the scanner with respect to the barcode to avoid d ...

  • Argox AS-8000 - page 4

    CONTENTS Chapter 1 Introduction Introduction…………………………..……………… . 1 Default Setting …………………………………… …. 2 ArgoxScan 8000 specification …………………….. 3 Programming the ArgoxScan 8000 Series Scanner 6 Chapter 2 Parameter Setting Interface………………………… ………? ...

  • Argox AS-8000 - page 5

    T elepen …………………………………………… …. 72 S tandard 2 of 5 …………………………………… … 74 RSS-14 …………………………………… …………. 76 RSS-Limited…………………………………..…… 78 RSS-Expanded…………………………………..….. 80 China Post ………… ...

  • Argox AS-8000 - page 6

    1 Introduction Inst allation- Keyboard Wedge 1) First of all, you must switch off power for the terminal/computer . 2) Disconnect the keyboard cable from the back of the terminal/computer and connect to the interface cable of the scanner . 3) Connect the interface cable of the scanner to the terminal/computer . 4) T urn the terminal/computer po wer ...

  • Argox AS-8000 - page 7

    2 Default setting For each barcode sho w n as below: Code T ype Read Enable Checksum V erification Enable Checksum T ransmission Enable Code ID UPC-A V V V A UPC-E V V V E EAN-13 V V V F EAN-8 V V V FF Code-39 V * Interleaved 2 of 5 V I Industrial 2 of 5 - - I Matrix 2 of 5 B Codabar % Code-128 V V # Code-93 V two digits & Code-1 1 V One digi ...

  • Argox AS-8000 - page 8

    3 AS-8000 Specification Weight 90 g (cable not included) Cable – K/B wedge S traight 2.0 m ArgoScan 8000 series S pecification Model AS-8000 series Operational Light Source 660 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field 0-180 mm (CODE 39, 500Lux, PCS=90%, 20mils) Scanning Width 50 mm wide @ 10mm S ...

  • Argox AS-8000 - page 9

    4 Connector type Crimp type female connector Case material ABS plastic Cushion material TPR Electrical Input V oltage 5 VDC ± 0.25V Power - Operating Max. 750 mW Power - S tandby 150 mW Current - Operating Max. 150 mA @ 5 VDC Current - S tandby 30 mA @ 5 VDC DC T ransformers Class 2; 5VDC @ 450 mA Agency listing FCC Class A, CE Environment al Oper ...

  • Argox AS-8000 - page 10

    5 Programming Programming method Manual (Reading special barcode), DOS command through RS-232 (RS-232 model) Programmable characteristics Code type selection, check digit selection, Decoding option T ransmitted character delay , Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard e ...

  • Argox AS-8000 - page 11

    6 Programming the ArgoScan 8000 Series Scanner T o program the 8000 series scanner , you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. Y ou will see a table of alphanumeric barcodes, which are used to program the various options presented. T o program each option, you must: 1. Scan the Progr ...

  • Argox AS-8000 - page 12

    7 Option Bar Code Option Alphanumeric Entry Scanning m ode Good-read off Momentary Alternate Timeout off Continue T est only 00 01 * 02 03 04 05 Program Exit Program Barcode Option Barcode Exit Barcode Back Fold Out Finish barcode ...

  • Argox AS-8000 - page 13

    8 Interface Selection This decoder built-in scanner comes in three models and supports interfaces such as keyboard wedge, RS232 serial, and the latest USB interface. Y ou will need to select an appropriate model for a specific interface. Interface selection: The factory interface default can not be changed for other type interface. One specific mod ...

  • Argox AS-8000 - page 14

    9 Exit Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The inst allation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard T ype: AS-8000 keyboard wedge model only supports keyboard interface with PS/2 type connector . Option Bar Code Option Alphanum ...

  • Argox AS-8000 - page 15

    10 Keyboard wedge Keyboard Lay out: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard” to select country at “l ...

  • Argox AS-8000 - page 16

    11 Exit Keyboard layout USA Belgium Danish France Germ any Italian Portuguese S panish Swedish Switzerland UK Latin American Japanese 00 * 01 02 03 04 05 06 07 08 09 10 11 12 Keyboard speed 0-8 0 : high clock rate 8 : low clock rate 00-08 03 * Function key Disable Enable 00 01 * Numeric key Alphabetic key Numeric keypad (Num lock state only) ...

  • Argox AS-8000 - page 17

    12 Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF” , scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present st ...

  • Argox AS-8000 - page 18

    13 Exit Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OFF” 00 01 * Power-on simulation Disable Enable 00 * 01 Inter-character dela y 00-99 msec 00-99 02 * Block transmission delay 00-99 10 msec 00-99 10 * Program ...

  • Argox AS-8000 - page 19

    14 RS-232 CTS: Clear T o Send (Hardware Signal) RTS: Request T o Send (Hardware Signal) Xon: T ransmit On (ASCII Code 1 1 16 ) Xoff: T ransmit Off (ASCII Code13 16 ) Flow control: None- The communication only us es TxD and RxD signals without regard for any hardware o r software handshaking protocol. RTS/CTS- If the scanner wants to send the barcod ...

  • Argox AS-8000 - page 20

    15 Exit Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xoff ACK/NAK 00 * 01 02 03 Inter-character dela y 00-99 (msec) 00-99 00 * Block transmission delay 00-99 (10 msec) 00-99 00 * Response delay 00-99 (100 msec) 00-99 20 * Program ...

  • Argox AS-8000 - page 21

    16 Exit Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02 03 04 05 * 06 07 Parity None Odd Even 00 * 01 02 Data bit 8 bits 7 bits 00 * 01 S top bit One bit T wo bits 00 * 01 Program ...

  • Argox AS-8000 - page 22

    17 Pin Assignment s Keyboard W edge Conne ctor (T o Ho st Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DA TA / PC CLK / KB 2 NC GND 3 GND DA TA / KB 4 VCC (+5V) VCC (+5V) 5 CLK / PC NC 6 NC NA RS-232 DB-9F Conne ctor (T o Host Side): Pin Definition 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 VCC (+5V) 4 2 3 1 8 6 9 7 5 3 1 2 4 5 3 4 5 6 2 1 ...

  • Argox AS-8000 - page 23

    18 Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep buzzer to indicate a good bar ...

  • Argox AS-8000 - page 24

    19 Exit Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01 * LED indication Disable Enable 00 01 * Beeper indication Disable Enable 00 01 * Beep loudness 00-07 00-07 07 * Beep tone freq. 00-99 (100Hz) 00-99 2 7 * Beep tone duration 00-99 (10 msec) 00-99 10 * Program ...

  • Argox AS-8000 - page 25

    20 T ransmission Preamble transmission : By setting Enable , Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable , Postamble will be appended after the data is transmitted. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00” to ...

  • Argox AS-8000 - page 26

    21 Exit Insert data group 1 position 00-63 (00: no insertion) 00-63 00 * Insert data group 2 position 00-63 (00: no insertion) 00-63 00 * Insert data group 3 position 00-63 (00: no insertion) 00-63 00 * Insert data group 4 position 00-63 (00: no insertion) 00-63 00 * Code ID position Before code data After code data 00 * 01 ...

  • Argox AS-8000 - page 27

    22 T ransmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length transmiss ion: A number of data digits can be transmitted before the code data when Enable is selected. The total length of the barcode is the number of barcode data except T runcate Leading/Ending Di ...

  • Argox AS-8000 - page 28

    23 Exit Code length transmission Disable Enable 00 * 01 Code name transmission Disable Enable 00 * 01 Case conversion Disable Upper case Lower case *For barcode data only 00 * 01 02 Format of barcode da ta transmission: Prefix Name Pr eamble ID Code Length Barcode data ID Postamble Suf fix Insert groups ...

  • Argox AS-8000 - page 29

    24 Scan Scanning mode: Good-read off- The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary- The trigger button acts as a switch. Press button to activate scanning and rel ease button to stop scanning ...

  • Argox AS-8000 - page 30

    25 Exit Scanning mode Good-read off Momentary Alternate T imeout off Continue T est only 00 01 * 02 03 04 05 S tand-by duration 01-99 (second) 01-99 06 * Double read timeout 01-99 (10 msec) 01-99 50 * Double confirm 00-99 (00: no double confirm) 00-09 00 * Supplement Check Counter 00-40 00-40 06 * ...

  • Argox AS-8000 - page 31

    26 Scan Global min./max. code length: Global Minimum and Maximum length can be set to qualify data entry . The length is defined as the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise the labels of th ...

  • Argox AS-8000 - page 32

    27 Exit Option Bar Code Option Alpha numeric Entry Global min. code length 00-64 00-64 04 * Global max.code length 00-64 00-64 63 * Inverted image scan Disable Enable 00 * 01 CTS trigger Disable Enable 00 * 01 *7AL* S tand mode selection LED ‘’on’’ LED ‘’off’’ 00 * 01 Program ...

  • Argox AS-8000 - page 33

    28 Exit String setting Prefix characters : Up to 22 ASCII characters may be sent before data digits. Pre fi x D ata Dig its Su ffi x Suffix characters: Up to 22 ASCII characters may be sent after data digit s. Option B ar Code Option Alphanume ric Entry Prefix characters setting None 1-22 characters 00 * 00-ffH ASCII code Suffix characters settin ...

  • Argox AS-8000 - page 34

    29 String setting Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded. Example: Add a prefix/suffix or preamble/ postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies. St e p s : 1) Scan Program ming and Prefix characters setting barcode. 2) Us ...

  • Argox AS-8000 - page 35

    30 Exit Preamble characters setting None 1-22 characters ‘PREAMBLE’ * 00-ffH ASCII code Postamble characters setting None 1-22 characters ‘POST AMBLE’ * 00-ffH ASCII code Insert G1 characters setting None 1-22 characters ‘GROUP1’ * 00-ffH ASCII code Insert G2 characters setting None 1-22 characters ‘GROUP2’ * 00-ffH ASCII co ...

  • Argox AS-8000 - page 36

    31 UPCA Read: Format Leading Zero Data Digits (1 1 Digit s) Check Digit Check-sum transmissi on: By setting Enable , checks sum will be transmitted. T runcate leading/ending: Th e leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the truncate val ...

  • Argox AS-8000 - page 37

    32 Exit Check-sum transmission Disable Enable 00 01 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < A > * Insert group selection 00-44 00-44 0 0 * ...

  • Argox AS-8000 - page 38

    33 Exit UPCA Supplement digi ts: The Supplement digits barcode is the supplemental 2 or 5 char acters for WPC code. Format Leading Zero Data Digits (1 1 Digit s) Check Digit Supplement Digits 2 or 5 or UCC / EAN 128 T runcation / Expansion: The leading “0” digits of UPCA data characters can be truncated when enabled. Option Bar Code Option Alph ...

  • Argox AS-8000 - page 39

    34 UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmissi on: By setting Enable , checks sum will be transmitted. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id set ...

  • Argox AS-8000 - page 40

    35 Exit T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < E > * ...

  • Argox AS-8000 - page 41

    36 UPCE Insertion group selection: Refer to Insertion grou p selection of UPCA. Supplement digits: Format Leading Zero Data Digits (6 Digits) Check Digit Supplement Digits 2 or 5 or UCC/EAN 128 Exp ansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with “0” digits when the feature is enabled. Ex ...

  • Argox AS-8000 - page 42

    37 Exit 2, UCC/EAN 128 5, UCC/EAN 128 All 05 06 07 T runcation/Expansion None T runcate leading zero Expand to EAN13 Expand to UPCA 00 * 01 02 03 Expansion Disable Enable 00 * 01 *OAM* UPCE-1 Disable Enable 00 * 01 ...

  • Argox AS-8000 - page 43

    38 EAN-13 Read: Format Data Digits (12 Digit s) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmissi on: By setting Enable , checks sum will be transmitted. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. The Option Bar Code ...

  • Argox AS-8000 - page 44

    39 Exit T runcate ending 0-15 00-15 00 * ...

  • Argox AS-8000 - page 45

    40 EAN-13 Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. Supplement digi ts: Format Data Digits (12 Digits) Check Digits Supplement Digits 2 or 5 or UCC / EAN 128 ISBN/ISSN: The ISBN (International S tandard Book Number) and ISSN (International St andard Serial Number) are ...

  • Argox AS-8000 - page 46

    41 Exit selection Supplement digits None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 00 * 01 02 03 04 05 06 07 ISBN/ISSN conversion Disable Enable 00 * 01 ...

  • Argox AS-8000 - page 47

    42 EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check-sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical value of the data digits. Check-sum transmissi on: By setting Enable , checks sum will be transmitted. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer t ...

  • Argox AS-8000 - page 48

    43 Exit T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting T wo characters 00-ffH ASCII code 00-ffH, 00-ffH < FF > * Insert group selection 00-44 00-44 00 * ...

  • Argox AS-8000 - page 49

    44 EAN-8 Supplement digi ts: Format Data Digits (7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 T runcation / Expansion: Refer to T runcate Leading zero of UPCE. Exp ansion: Refer to Expansion of UPCE. Option Bar Code Option Alphanumeric Entry Supplement digits None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN ...

  • Argox AS-8000 - page 50

    45 Exit T runcation / Expansion None T runcate leading zero Expand to EAN13 00 * 01 02 Expansion Disable Enable 00 * 01 ...

  • Argox AS-8000 - page 51

    46 Code 39 Read: Format Sta rt “ ★ ” Data Digits ( V ariable) Checksum (Optional) End “ ★ ” Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmissi on: By setting Enable , checksum will be transmitted. Max./Min. code length: Each symbology ...

  • Argox AS-8000 - page 52

    47 Exit Check-sum verification Disable Enable 00 * 01 Check-sum transmission Disable Enable 00 * 01 Max. code length 00-64 00-64 00 * Min. code length 00-64 00-64 00 * T runcate leading 0-20 00-20 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < * > ...

  • Argox AS-8000 - page 53

    48 Code 39 Insertion group selection: Refer to Insertion grou p selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z). Append: This function allows several symbols ...

  • Argox AS-8000 - page 54

    49 Exit Format S tandard Full ASCII 00 * 01 Append Disable Enable 00 * 01 S tart/end transmission Disable Enable 00 * 01 ...

  • Argox AS-8000 - page 55

    50 Interleaved 2 of 5 Read: Format Data Digits (V ariable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmissi on: By setting Enable , checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/en ...

  • Argox AS-8000 - page 56

    51 Exit Check-sum transmission Disable Enable 00 * 01 Max. code leading 00-64 00-64 00 * Min. code leading 00-64 00-64 00 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < i > * Insert group selection 00-44 00-44 00 * ...

  • Argox AS-8000 - page 57

    52 Industrial 2 of 5 Read: Format Data Digits (V ariable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. Option Bar C ...

  • Argox AS-8000 - page 58

    53 Exit T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < i > * Insert group selection 00-44 00-44 00 * ...

  • Argox AS-8000 - page 59

    54 Matrix 2 of 5 Eur Read: Format Data Digits (V ariable) Checksum (Optional) Checksum V erification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum T ransmission: B y setting Enable , checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/end ...

  • Argox AS-8000 - page 60

    55 Exit Checksum T ransmission Disable Enable 00 * 01 Max. code length 00-64 00-64 00 * Min. code length 00-64 00-64 00 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < B > * Insert group selection 00-44 00- 44 00 * ...

  • Argox AS-8000 - page 61

    56 Codabar Read: Format Checksum V erification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum T ransmission: B y setting Enable , checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code ...

  • Argox AS-8000 - page 62

    57 Exit Checksum T ransmission Disable Enable 00 * 01 Max. code length 00-64 00-64 00 * Min. code length 00-64 00-64 00 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < % > * ...

  • Argox AS-8000 - page 63

    58 Exit Codabar Insertion group selection: Refer to Insertion grou p selection of UPCA. St art/End type: The Codabar h as four pairs of S tart/End pattern; you may select one pair to match your application. St art/End T ransmission: Refer to Start/End Transmission of Code 39. Option B ar Code Option Alphanume ric Entry Insert group selection 00-44 ...

  • Argox AS-8000 - page 64

    59 Exit Code-128 Read: Format Data Digits (V ariable) Checksum (Optional) Checksum V erification: The checksum is made as the sum module 103 of all data digits. Checksum T ransmission: B y setting Enable , checksum will be transmitted. Option B ar Code Option Alphanume ric Entry Read Disable Enable 00 01 * Checksum V erification Disable Enable 00 ...

  • Argox AS-8000 - page 65

    60 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. Format: The Co de-128 can be translated to UCC/EAN-128 format if it start s wi ...

  • Argox AS-8000 - page 66

    61 Exit T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < # > * Insert group selection 00-44 00-44 00 * Format S tandard UCC/EAN-128 00 * 01 ...

  • Argox AS-8000 - page 67

    62 Exit Code-128 Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn't have FNC2 code. UCC/ EAN 128 ID setting : T o setting the code ID for UCC/EAN-128 output format. Field separator code: This feature is only ...

  • Argox AS-8000 - page 68

    63 Exit Code-93 Read: Format Data Digits (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum T ransmission: B y setting Enable , checksum will be transmitted. Option B ar Code Option Alphanume ric Entry Read Disable Enable 00 * ...

  • Argox AS-8000 - page 69

    64 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. Option B ar Code Option Alphanume ric Entry Max. code length 00-64 00-64 00 * ...

  • Argox AS-8000 - page 70

    65 Exit Code ID setting 00-ffH ASCII code 00-ffH < & > * Insert group selection 00-44 00-44 00 * ...

  • Argox AS-8000 - page 71

    66 Code-1 1 Read: Format Data Digits (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The checksum is presented as the sum module 1 1 of all dat a digits. Checksum T ransmission: B y setting Enable , checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer ...

  • Argox AS-8000 - page 72

    67 Exit Checksum T ransmission Disable Enable 00 * 01 Max. code length 00-64 00-64 00 * Min. code length 00-64 00-64 00 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < O > * Insert group selection 00-44 00-44 00 * ...

  • Argox AS-8000 - page 73

    68 MSI/plessey Read: Format Data Digits (V ariable) Checksum1 (Optional) Checksum2 (Optional) Checksum V erification: The MSI/Plessey has one or t wo optional checksum digits. The checksum is presented 3 kinds of method Mod10 , Mod10/1 0 and Mod 1 1/10 . The checksum1 and checksum2 will be calculated as the sum module 10 or 1 1 of the data digit s. ...

  • Argox AS-8000 - page 74

    69 Exit Checksum T ransmission Disable Enable 00 * 01 Max. code length 00-64 00-64 00 * Min. code length 00-64 00-64 00 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < @ > * Insert group selection 00-44 00-44 00 * ...

  • Argox AS-8000 - page 75

    70 UK/plessey Read: Format Data Digits (V ariable) Checksum1+2 (Optional) Checksum V erification: The UK/P lessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 1 1 of the data digits. Checksum T ransmission: B y setting Enable , checksum will be transmitted. Max./Min. code length: Re ...

  • Argox AS-8000 - page 76

    71 Exit Checksum T ransmission Disable Enable 00 * 01 Max. code length 00-64 00-64 00 * Min. code length 00-64 00-64 00 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < @ > * Insert group selection 00-44 00-44 00 * ...

  • Argox AS-8000 - page 77

    72 T elepen Read: IA T A (International Air T ransport Association). Checksum V erification: The checksum is presented as the sum module 10 or 1 1 of the data digit s. Checksum T ransmission: B y setting Enable , checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Ref er to T run ...

  • Argox AS-8000 - page 78

    73 Exit Max. code length 00-64 00-64 00 * Min. code length 00-64 00-64 00 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < S > * Insert group selection 00-44 00-44 00 * Format Numeric only Full ASCII only 00 * 01 ...

  • Argox AS-8000 - page 79

    74 St andard 2 of 5 Read: Format Data Digits (V ariable) Checksum1 (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmissi on: By setting Enable , checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/end ...

  • Argox AS-8000 - page 80

    75 Exit *JAC* Check-sum transmission Disable Enable 00 * 01 Max. code length 00-64 00-64 00 * Min. code length 00-64 00-64 00 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < i > * Insert group selection 00-44 00-44 00 * ...

  • Argox AS-8000 - page 81

    76 RSS-14 Read: Format Data Digits (V ariable) Checksum1 (Optional) T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. UCC/EAN 128 emulation: Refer to T ransmission, Code ID transmission must be set as AIM I ...

  • Argox AS-8000 - page 82

    77 Exit Code ID setting Insert group selection 00-44 00-44 00 * UCC/EAN128 emulation Disable Enable 00 * 01 ...

  • Argox AS-8000 - page 83

    78 RSS-Limited Read: Format Data Digits (V ariable) Checksum1 (Optional) T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14. Option B ar Code O ...

  • Argox AS-8000 - page 84

    79 Exit Code ID setting 00-ffH ASCII code 00-ffH < RL > * Insert group selection 00-44 00-44 00 * UCC/EAN128 emulation Disable Enable 00 * 01 ...

  • Argox AS-8000 - page 85

    80 RSS-Exp anded Read: Format Data Digits (V ariable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. UCC/EAN 128 emu ...

  • Argox AS-8000 - page 86

    81 Exit Min. code length 00-99 00-99 01 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < RX > * Insert group selection 00-44 00-44 00 * UCC/EAN128 emulation Disable Enable 00 * 01 ...

  • Argox AS-8000 - page 87

    82 China Post Read: Format Data Digits (V ariable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. Option B ar Code O ...

  • Argox AS-8000 - page 88

    83 Exit T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 00-ffH < t > * Insert group selection 00-44 01-44 00 * ...

  • Argox AS-8000 - page 89

    84 It alian Pharmacode Read: Format Data Digits (V ariable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. T runcate leading/ending: Ref er to T runcate leading/ending of UPCA. Code Id setting: Refer to Code I D setting of UPCA. Insertion group selection: Refer to Insertion grou p selection of UPCA. Leading ? ...

  • Argox AS-8000 - page 90

    85 Exit Min. code length 00-64 00-64 09 * T runcate leading 0-15 00-15 00 * T runcate ending 0-15 00-15 00 * Code ID setting 00-ffH ASCII code 01-ffH < p > * Insert group selection 00-44 00-44 00 * Leading “A” Disable Enable 00 * 01 ...

  • Argox AS-8000 - page 91

    86 Test Chart CODABAR-P ARA CODE-1 1 P ARA CODE-128 P ARA CODE-39 P ARA CODE-93 P ARA EAN-13 P ARA ...

  • Argox AS-8000 - page 92

    87 ST ANDRAD-25 P ARA EAN-8 P ARA INDUSTRIAL-25 P ARA UPCE P ARA INTERLEA VED-25 P ARA ...

  • Argox AS-8000 - page 93

    88 MA TRI X 25 P ARA MSI/PLESSEY P ARA UPCA P AR A UK/PLESSEY P ARA RSS ...

  • Argox AS-8000 - page 94

    89 ASCII Code T able Note: For keyboard wedge only. L H 0 1 0 1 0 Nu ll NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right F4 EOT DC4 5 PgUp F5 ENQ NAK 6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl+ SO RS F Delete Alt+ SI US L H 2 3 4 5 6 ...

  • Argox AS-8000 - page 95

    90 Parameter Setting List Program Barcode standard p arameter setting list If you wish to display the current configuration of your AS-8000 scanner over the host terminal/computer , scan the Barcode standard parameter setting list bar code. Unique parameter list If you wish to display the unique parameter setting list, scan the unique parameter lis ...

  • Argox AS-8000 - page 96

    91 Exit Firmware version list If you wish to display the firmware version, scan the Firmware version l ist. W ARNING : Default value initialization If you wish to return the AS-8000 scanner to all the factory default settings, scan the Default value initialization bar code. ...

  • Argox AS-8000 - page 97

    92 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D ...

メーカー Argox カテゴリー Scanner

Argox AS-8000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AS-8000の取扱説明書
- Argoxの製品カード
- パンフレット
- またはArgox AS-8000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Argox AS-8000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Argox AS-8000の取り付け説明書、サービスマニュアル、簡易説明書、またはArgox AS-8000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Argox AS-8000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Argox AS-8000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがArgox AS-8000を使用するのを助ける技術的文書のことです。説明書は通常、全てのArgox AS-8000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Argoxの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Argox AS-8000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははArgox AS-8000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Argox AS-8000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Argox AS-8000デバイスの基本機能を使うにあたってのヒント。 Argox AS-8000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Argox AS-8000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるArgox AS-8000のメーカー/サービスへの連絡先に関する情報。

Argox AS-8000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもArgox AS-8000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがArgox AS-8000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)