Manual Roper llc-200

18 pages 0.47 mb
Download

Go to site of 18

Summary
  • Roper llc-200 - page 1

    4411-0068 Version 1.A December 10, 1997  ...

  • Roper llc-200 - page 2

    ...

  • Roper llc-200 - page 3

    iii Table of Contents Model IIC-200 Image Intensifier Controller ........................................................ 5 Introduction ......................................................................................................................... 5 Dangers and Warnings .................................................................... ...

  • Roper llc-200 - page 4

    iv Model IIC-200 Operation Manual Version 1.A This page intentionally left blank. ...

  • Roper llc-200 - page 5

    5 Model IIC-200 Image Intensifier Controller Introduct ion The IIC-200 is a stand-alone image intensifier controller. It supplies high-voltage DC bias for Princeton Instruments image intensifiers plus circuitry to facilitate gating. Gating pulses are provided by a Princeton Instruments high voltage pulser. The IIC-200 allows front-panel control of ...

  • Roper llc-200 - page 6

    6 Model IIC-200 Operation Manual Version 1.A The IIC-200 allows both Shutter and Gated modes of operation. Gating pulses can range from 5 nsec to DC. Longer gate experiments can also use the 5 volt logic electronic shutter control. Danger s and Warnings Voltages inside the IIC-200 may exceed 10,000 volts. To avoid possible hazard to personnel, use ...

  • Roper llc-200 - page 7

    Version 1.A Model IIC-200 Operation Manual 7 Note: The Model IIC-200 has automatic circuitry to help prevent damage. However, it is far better not to place an expensive intensifier at risk than to depend on the protection circuitry. Features Independently variable MCP power supply, independent of phosphor voltage. Automatic alarm and shutdown in ca ...

  • Roper llc-200 - page 8

    8 Model IIC-200 Operation Manual Version 1.A Front Pane l Feature s MCP GA IN: This adjustment is used to control the gain of the MCP by controlling the voltage across it. Display units are arbitrary. SHUTTER/GATE: This switch selects between Gate mode or Shutter mode. In Gate mode, the intensifier is normally off and a high-voltage gate pulse is n ...

  • Roper llc-200 - page 9

    Version 1.A Model IIC-200 Operation Manual 9 The plug on the line cord supplied with the system should be compatible with the line-voltage outlets in common use in the region to which the system is shipped. If the line cord plug should prove to be incompatible, a compatible plug should be installed, taking care to maintain the proper polarity to pr ...

  • Roper llc-200 - page 10

    10 Model IIC-200 Operation Manual Version 1.A Hardware O verview The IIC-200 consists of a printed circuit board and a modular high voltage supply which are mounted in a stand-alone chassis. The IIC-200 contains circuitry for the following functions: A variable high voltage power supply for the MCP voltage. The MCP voltage is a linear function of t ...

  • Roper llc-200 - page 11

    Version 1.A Model IIC-200 Operation Manual 11 Shutter circuitry which allows an electrically isolated logic signal to control the voltage between the Photocathode and MCP In. This allows long gate times or C W operation. Operatio n ➧ Review the Danger and Warning notices on page 6 before operating the IIC-200. ➧ Set the IIC-200 Power switch to ...

  • Roper llc-200 - page 12

    12 Model IIC-200 Operation Manual Version 1.A Connections with a Gen IV I ntensi fi er ➧ Connect one end of the high-voltage cable supplied by Roper Scientific to the high-voltage connector on the image intensifier. If you have purchased more than one image intensifier, make sure you are using the cable supplied with this intensifier. The connect ...

  • Roper llc-200 - page 13

    Version 1.A Model IIC-200 Operation Manual 13 Power Up Steps ➧ Make sure the front-panel MCP Power switch is O ff. Adjust MCP G ain to minimum and turn on the chassis power. Note: As long as the image intensifier and IIC-200 are purchased from Roper Scientific as part of the same order, the upper limit circuit will be set for the maximum safe lim ...

  • Roper llc-200 - page 14

    14 Model IIC-200 Operation Manual Version 1.A Scientific highly recommends updating old units at the user’s earliest convenience. Contact the factory for details. Connecting the wrong cable at both ends can result in non-functioning of the image intensifier. If you suspect that you may be using the wrong cable for your intensifier, contact the fa ...

  • Roper llc-200 - page 15

    15 Warranty & Service Warranty This equipment is warranted to be free from defects of material and workmanship. It is sold subject to the mutual agreement that the liability of Roper Scientific is limited to replacing defective parts and/or repairing malfunctioning equipment at its factory, provided the equipment is returned, transportation pre ...

  • Roper llc-200 - page 16

    16 Model IIC-200 Operation Manual Version 1.A Con tact Informatio n Roper Scientific’s manufacturing facility is located at the following address: Roper Scientific 3660 Quakerbridge Road Trenton, NJ 08619 (USA) Tel: 609-587-9797 Fax: 609-587-1970 Tech Support E-mail: techsupport@roperscientific.com For technical support and service outside the Un ...

  • Roper llc-200 - page 17

    17 Index Alarm circuit, 10 Audio beeper, 7 Auto Bright Co ntrol switch, 8 Auto Bright ness C ontrol, 7, 10 Beeper, 7 Bias levels MCP-In, 7 MCP-Out, 7 phosphor, 7 Brightnes s control, 7, 10 Contact informat ion, 16 e-mail address, 16 street address, 16 teelphone and fax numbers, 16 web site, 16 CW mod e, 7 CW operation (Gen IV), 12 Fuses, 9 Gain red ...

  • Roper llc-200 - page 18

    18 Model IIC-200 Operation Manual Version 1.A This page intentionally left blank. ...

Manufacturer Roper Category Home Theater Server

Documents that we receive from a manufacturer of a Roper llc-200 can be divided into several groups. They are, among others:
- Roper technical drawings
- llc-200 manuals
- Roper product data sheets
- information booklets
- or energy labels Roper llc-200
All of them are important, but the most important information from the point of view of use of the device are in the user manual Roper llc-200.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Roper llc-200, service manual, brief instructions and user manuals Roper llc-200. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Roper llc-200.

Similar manuals

A complete manual for the device Roper llc-200, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Roper llc-200 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Roper llc-200.

A complete Roper manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Roper llc-200 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Roper llc-200, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Roper llc-200, that we can find in the current document
3. Tips how to use the basic functions of the device Roper llc-200 - which should help us in our first steps of using Roper llc-200
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Roper llc-200
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Roper llc-200 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Roper llc-200?

Use the form below

If you did not solve your problem by using a manual Roper llc-200, ask a question using the form below. If a user had a similar problem with Roper llc-200 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)