  • Dayton 3VG80 - page 1

    Dayton Pr opane Construction Heater Description Dayton Model 3VG80 heater is a variable 65,000, 85,000, and 100,000 Btu/Hr construc- tion heater . This heater uses propane gas for combustion. It is primarily intended for temporary heating of well-ventilated buildings under construction, alteration, or r epair . This heater should only be used indoo ...

  • Dayton 3VG80 - page 2

    Dayton Operating Instructions and Parts Manual 3VG80 2 Dayton Pr opane Construction Heater ® General Safety Information Make certain you read and understand a ll warnings. Keep these instructions for refer ence. They are your guide to safe and proper operation of this heater . Safety information appears throughout these instructions. Pay close att ...

  • Dayton 3VG80 - page 3

    Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 3 Model 3VG80 • Locate heater on stable and level surface if heater is hot or operating. • Never block air inlet (rear) or air outlet (front) of heater . • Keep heater away from str ong drafts, wind, water spray , rain, or dripping water . • Never operate hea ...

  • Dayton 3VG80 - page 4

    Dayton Operating Instructions and Parts Manual 3VG80 4 Dayton Pr opane Construction Heater ® Figure 2 - Pr oduct Identification Handle Power Cord Hose /Regulator Assembly Hot Air Outlet (Front) Inlet Connector Control Knob Motor Mount Fan Guard Product Identification ...

  • Dayton 3VG80 - page 5

    Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 5 Model 3VG80 Air For Combustion And Heating Fuel Combustion Chamber Figure 3 - Cross Section Operational V iew Clean Heated Air Out (Front) Hose/Regulator Assembly Nozzle Fan Cool Air In (Back) Power Cord THE FUEL SYSTEM The hose/regulator assembly attaches to the p ...

  • Dayton 3VG80 - page 6

    Dayton Operating Instructions and Parts Manual 3VG80 6 Dayton Pr opane Construction Heater ® Installation Review and understand the warnings in the General Safety Infor - mation section, pages 2 and 3. They ar e needed to safely operate this heater . Follow all local codes when using this heater . T est all gas piping and connections for leaks aft ...

  • Dayton 3VG80 - page 7

    Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 7 Model 3VG80 5. Plug extension cord into a 120 V olt/60 Hertz, 3-hole, grounded outlet. Motor will start. Fan will turn, forcing air out front of heater . 6. Open propane supply valve on pr opane tank(s) slowly . NOTE: If not opened slowly , excess-flow check valve ...

  • Dayton 3VG80 - page 8

    Dayton Operating Instructions and Parts Manual 3VG80 8 Dayton Pr opane Construction Heater ® Maintenance (Continued) Ground Screw T er minal Board Motor Green Lead T ransfor mer Green Lead Power Cord Green Lead Figure 6 - Location of Gr ound Screw Hole in Shell for Wires Motor Mount Screw Fan Guard Motor Mount Figure 7- Removing Motor , Motor Moun ...

  • Dayton 3VG80 - page 9

    Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 9 Model 3VG80 5. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds). 6. Place motor , motor mount, and fan guard into r ear of heater shell (See Motor , page 8, steps 14 through 18). Maintenance (Continued) Fan Hub Setscrew Motor Shaft Figur ...

  • Dayton 3VG80 - page 10

    Dayton Operating Instructions and Parts Manual 3VG80 10 Dayton Pr opane Construction Heater ® Wiring Diagram 100,000 BUT/HR MODEL Black Green White Motor Ignitor Orange Blue Blue Auto Control V alve Thermocouple 12 34 56 8 7 Thermal Switch T erminal Board Blue Black Ignition Control White Relay Green Green Black Black White White Green Power Cord ...

  • Dayton 3VG80 - page 11

    Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 11 Model 3VG80 T roubleshooting Chart Never attempt to service heater while it is plugged in, connected to pr opane supply , operating, or hot. Severe burns and electrical shock can occur . Symptom Possible Cause(s) Corrective Action 1. No electrical power to heater ...

  • Dayton 3VG80 - page 12

    Dayton Operating Instructions and Parts Manual 3VG80 12 Dayton Pr opane Construction Heater ® For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Figure 15 - Repair Parts Illustration Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts corr ...

  • Dayton 3VG80 - page 13

    Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 13 Model 3VG80 Repair Parts List ( ) Not shown. (*) Standard har dware item, available locally . 1 Base T ray 102362-01 1 2 *Hex TPG Screw , 10-16 X 38 M11084-26 15 3 Base 103917-01AA 1 4 Nozzle 099138-02 1 5 Shell Kit 098511-216 1 6 *Hex TPG Screw ,10-16 X .75 M1108 ...

  • Dayton 3VG80 - page 14

    Dayton Operating Instructions and Parts Manual 3VG80 103029-01 Rev . E 10/02 Version B - For Reduction G016.J ® Dayton Pr opane Construction Heater LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Dayton propane construction heater, Models covered in this manual, are warranted by Dayton Electric Mfg. Co. (Dayton) to the original user against def ...

Manufacturer Dayton Category Stove

Documents that we receive from a manufacturer of a Dayton 3VG80 can be divided into several groups. They are, among others:
- Dayton technical drawings
- 3VG80 manuals
- Dayton product data sheets
- information booklets
- or energy labels Dayton 3VG80
All of them are important, but the most important information from the point of view of use of the device are in the user manual Dayton 3VG80.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Dayton 3VG80, service manual, brief instructions and user manuals Dayton 3VG80. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Dayton 3VG80.

Similar manuals

A complete manual for the device Dayton 3VG80, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Dayton 3VG80 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Dayton 3VG80.

A complete Dayton manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Dayton 3VG80 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Dayton 3VG80, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Dayton 3VG80, that we can find in the current document
3. Tips how to use the basic functions of the device Dayton 3VG80 - which should help us in our first steps of using Dayton 3VG80
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Dayton 3VG80
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Dayton 3VG80 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Dayton 3VG80?

Use the form below

If you did not solve your problem by using a manual Dayton 3VG80, ask a question using the form below. If a user had a similar problem with Dayton 3VG80 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)