Manual Drive Medical Design 18605

16 pages 0.2 mb
Download

Go to site of 16

Summary
  • Drive Medical Design 18605 - page 1

    portable ac/dc suction pump USER’S MANU AL ITEM # 18605 ...

  • Drive Medical Design 18605 - page 2

    inde x C A UTION F ederal law r es tricts this device t o sale by or on or der of a ph ysician, or any o ther practit ioner licensed b y the law of the Stat e in which he practice s to use or order the use o f this devic e. NO TE Check ALL parts for shipping damage . If shipping damage is no ted, DO NO T use. Contact medi- cal equipment pr o vider ...

  • Drive Medical Design 18605 - page 3

    safety information ! 1. SAFETY INFORMA TION When using electrical products, especially when childr en ar e presen t, basic safety prec autions should alway s be follo wed. R ead all instructions bef ore using. Important inf ormation is highlighted b y these terms: D ANGER Ur gent safe ty information f or hazar ds that will cause serious injury or d ...

  • Drive Medical Design 18605 - page 4

    SPECIFIC W ARNINGS T O REDUCE THE RISK OF ELECTRIC AL SHOCK OR INJUR Y T O PERSONS, DO NO T DISA SSEMBLE THIS UNIT . DISA SSEMBL Y OR A T TEMPTED REP AIRS IF A CCOMPLISHED INCORRECTL Y C AN CREA TE ELECTRIC AL SHOCK HAZARD . ONL Y QU ALIFIED TECHNICIANS SHOULD PERFORM SER VICING OF THIS SUCTION UNIT . D ANGER The A C/DC P ortable Suction Pump is a ...

  • Drive Medical Design 18605 - page 5

    safety information 4 W ARNING Pr oper operation o f this product is nece ssary to avoid ph ysical harm. I mproper use can c ause personal injury and/ or tissue damage. This pr oduct should not be used unless the oper ator has been instructed b y a phy sician or other qualified health car e pr ofe ssional. ! introduction F eature s: Ne w anti-bacte ...

  • Drive Medical Design 18605 - page 6

    Item # 1860 5 1. Bacteria filter (non-s terile ) 2. 4 ” Connection tubing 3. V acuum gauge 4. T ubing connector 5. V acuum regulator knob 6 . DC po wer input ( on side) 7 . P o w er swit ch 8. 6 ’ patient tubing 9 . 800 cc disposable canis ter w /lid (float shut o ff incorpor ated in to lid) 10 . 90 o conne ction elbo w illustration of import ...

  • Drive Medical Design 18605 - page 7

    set up & operation 6 IMPORT ANT OPERA TION AND BA T TER Y INS TRUCTIONS: Y our 18605 portable suction machine is capable to run on A C or DC po wer . T o ensure full func- tion of this unit, the battery mus t be completely char ged bef ore the fir st use . Do not turn on the unit befor e the battery is complet ely charged. It t ake s appro xim ...

  • Drive Medical Design 18605 - page 8

    set up & operation 7 BA TTERY OPERA TION: T o ensur e pr oper operation fr om internal ba ery , fully char ge the baery for 1.5 hour s as e xplained in the Baery Char ging section. T o oper ate the unit fr om an internal r echargeable ba ery , ensur e that no e x ternal pow er sour ces ar e plugged into the DC pow er input on the si ...

  • Drive Medical Design 18605 - page 9

    cleaning & maintenance 8 BA TTERY CHARGING On 1860 5 series, the units are equipped with a f actory -installed r echar geable baery . The unit will hav e a light for lo w baery and charge indic ation. Once y ou’ ve de termined that y our unit is equipped with an internal r echargeable baery , con- nect the unit to the proper A C or D ...

  • Drive Medical Design 18605 - page 10

    9 cleaning &maintenance Collection Bo le: 1. Shut off unit using po w er switch and allo w v acuum to drop . Disconnect po wer sour ce fr om the DC input rec eptacle on the unit. 2. With the collection bo le s till in the holder , remo v e the lid. The bole c an now be tak en out o f the holder to be empt ied. NO TE Collection bo l ...

  • Drive Medical Design 18605 - page 11

    10 maintenance & troubleshooting MAINTENANCE Inspect suction tubing and collection bo le for leaks, cr acks, etc. bef ore each use . D ANGER Electric shock haz ard. D o not aemp t to open or remo v e cabinet, ther e are no user -serviceable internal componen ts. If service is r equired, r eturn unit to a qualified D rive M edical pro vid ...

  • Drive Medical Design 18605 - page 12

    11 specifications / classification Size H x W x D inche s (cm ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.2 x 7 .0 x 8. 0 (36 x 17 .8 x 20 .3) W eight lb. (k g.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 .3 lbs (3.3 k g) Electrical R equirements . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Drive Medical Design 18605 - page 13

    12 specifications / classification APPRO V ALS 18605 Serie s . . . . . . . . . . . . . . . . . . . . . . . . . . . .IEC 601- 1; C AN/ C SA -C22.2 No . 601. 1-M90; UL 60601- 1, EN 60601- 1- 2 18605 mee ts RT CA/D- 160D . . . . . . . . . . . . . . . . . . . . . . . . .DO- 160D - sec tion 21 Category M EQUIP MENT CLASSIFIC A TIONS W ith re spect to ...

  • Drive Medical Design 18605 - page 14

    warranty TW O- YEAR LIMITED W ARRANTY The compr essor portion of the D rive Suction U nit 18605 Serie s (e x cluding internal r echargeable baeries ) is warr anted to be fr ee fr om defectiv e w orkmanship and materials for a period o f two y ear s from date o f purchase . Internal rechar geable baeries ar e w arrant ed for 90 days. An y defe ...

  • Drive Medical Design 18605 - page 15

    DECLARA TION OF CONFORMITY M anufactur er: Driv e M edical D esign & M anufacturing 99 Seaview Boule v ard P ort W ashington, NY 11050 Pr oduct Designation : T ype/M odel: 1860 5 W e herewith declar e that the abo v e-mentioned product complie s with the requir ements of E C Dir ective 9 3/ 42/EEC and the follo wing: Class: II a, Rule 2 Quality ...

  • Drive Medical Design 18605 - page 16

    Driv e M edical De sign & M anufacturing 99 Seaview Boule v ard P ort W ashington, NY 11050 ...

Manufacturer Drive Medical Design Category Oxygen Equipment

Documents that we receive from a manufacturer of a Drive Medical Design 18605 can be divided into several groups. They are, among others:
- Drive Medical Design technical drawings
- 18605 manuals
- Drive Medical Design product data sheets
- information booklets
- or energy labels Drive Medical Design 18605
All of them are important, but the most important information from the point of view of use of the device are in the user manual Drive Medical Design 18605.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Drive Medical Design 18605, service manual, brief instructions and user manuals Drive Medical Design 18605. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Drive Medical Design 18605.

A complete manual for the device Drive Medical Design 18605, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Drive Medical Design 18605 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Drive Medical Design 18605.

A complete Drive Medical Design manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Drive Medical Design 18605 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Drive Medical Design 18605, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Drive Medical Design 18605, that we can find in the current document
3. Tips how to use the basic functions of the device Drive Medical Design 18605 - which should help us in our first steps of using Drive Medical Design 18605
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Drive Medical Design 18605
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Drive Medical Design 18605 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Drive Medical Design 18605?

Use the form below

If you did not solve your problem by using a manual Drive Medical Design 18605, ask a question using the form below. If a user had a similar problem with Drive Medical Design 18605 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)