Инструкция обслуживания Drive Medical Design 18605

16 страниц 0.2 mb
Скачать

Перейти на страницу of 16

Summary
  • Drive Medical Design 18605 - page 1

    portable ac/dc suction pump USER’S MANU AL ITEM # 18605 ...

  • Drive Medical Design 18605 - page 2

    inde x C A UTION F ederal law r es tricts this device t o sale by or on or der of a ph ysician, or any o ther practit ioner licensed b y the law of the Stat e in which he practice s to use or order the use o f this devic e. NO TE Check ALL parts for shipping damage . If shipping damage is no ted, DO NO T use. Contact medi- cal equipment pr o vider ...

  • Drive Medical Design 18605 - page 3

    safety information ! 1. SAFETY INFORMA TION When using electrical products, especially when childr en ar e presen t, basic safety prec autions should alway s be follo wed. R ead all instructions bef ore using. Important inf ormation is highlighted b y these terms: D ANGER Ur gent safe ty information f or hazar ds that will cause serious injury or d ...

  • Drive Medical Design 18605 - page 4

    SPECIFIC W ARNINGS T O REDUCE THE RISK OF ELECTRIC AL SHOCK OR INJUR Y T O PERSONS, DO NO T DISA SSEMBLE THIS UNIT . DISA SSEMBL Y OR A T TEMPTED REP AIRS IF A CCOMPLISHED INCORRECTL Y C AN CREA TE ELECTRIC AL SHOCK HAZARD . ONL Y QU ALIFIED TECHNICIANS SHOULD PERFORM SER VICING OF THIS SUCTION UNIT . D ANGER The A C/DC P ortable Suction Pump is a ...

  • Drive Medical Design 18605 - page 5

    safety information 4 W ARNING Pr oper operation o f this product is nece ssary to avoid ph ysical harm. I mproper use can c ause personal injury and/ or tissue damage. This pr oduct should not be used unless the oper ator has been instructed b y a phy sician or other qualified health car e pr ofe ssional. ! introduction F eature s: Ne w anti-bacte ...

  • Drive Medical Design 18605 - page 6

    Item # 1860 5 1. Bacteria filter (non-s terile ) 2. 4 ” Connection tubing 3. V acuum gauge 4. T ubing connector 5. V acuum regulator knob 6 . DC po wer input ( on side) 7 . P o w er swit ch 8. 6 ’ patient tubing 9 . 800 cc disposable canis ter w /lid (float shut o ff incorpor ated in to lid) 10 . 90 o conne ction elbo w illustration of import ...

  • Drive Medical Design 18605 - page 7

    set up & operation 6 IMPORT ANT OPERA TION AND BA T TER Y INS TRUCTIONS: Y our 18605 portable suction machine is capable to run on A C or DC po wer . T o ensure full func- tion of this unit, the battery mus t be completely char ged bef ore the fir st use . Do not turn on the unit befor e the battery is complet ely charged. It t ake s appro xim ...

  • Drive Medical Design 18605 - page 8

    set up & operation 7 BA TTERY OPERA TION: T o ensur e pr oper operation fr om internal ba ery , fully char ge the baery for 1.5 hour s as e xplained in the Baery Char ging section. T o oper ate the unit fr om an internal r echargeable ba ery , ensur e that no e x ternal pow er sour ces ar e plugged into the DC pow er input on the si ...

  • Drive Medical Design 18605 - page 9

    cleaning & maintenance 8 BA TTERY CHARGING On 1860 5 series, the units are equipped with a f actory -installed r echar geable baery . The unit will hav e a light for lo w baery and charge indic ation. Once y ou’ ve de termined that y our unit is equipped with an internal r echargeable baery , con- nect the unit to the proper A C or D ...

  • Drive Medical Design 18605 - page 10

    9 cleaning &maintenance Collection Bo le: 1. Shut off unit using po w er switch and allo w v acuum to drop . Disconnect po wer sour ce fr om the DC input rec eptacle on the unit. 2. With the collection bo le s till in the holder , remo v e the lid. The bole c an now be tak en out o f the holder to be empt ied. NO TE Collection bo l ...

  • Drive Medical Design 18605 - page 11

    10 maintenance & troubleshooting MAINTENANCE Inspect suction tubing and collection bo le for leaks, cr acks, etc. bef ore each use . D ANGER Electric shock haz ard. D o not aemp t to open or remo v e cabinet, ther e are no user -serviceable internal componen ts. If service is r equired, r eturn unit to a qualified D rive M edical pro vid ...

  • Drive Medical Design 18605 - page 12

    11 specifications / classification Size H x W x D inche s (cm ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.2 x 7 .0 x 8. 0 (36 x 17 .8 x 20 .3) W eight lb. (k g.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 .3 lbs (3.3 k g) Electrical R equirements . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Drive Medical Design 18605 - page 13

    12 specifications / classification APPRO V ALS 18605 Serie s . . . . . . . . . . . . . . . . . . . . . . . . . . . .IEC 601- 1; C AN/ C SA -C22.2 No . 601. 1-M90; UL 60601- 1, EN 60601- 1- 2 18605 mee ts RT CA/D- 160D . . . . . . . . . . . . . . . . . . . . . . . . .DO- 160D - sec tion 21 Category M EQUIP MENT CLASSIFIC A TIONS W ith re spect to ...

  • Drive Medical Design 18605 - page 14

    warranty TW O- YEAR LIMITED W ARRANTY The compr essor portion of the D rive Suction U nit 18605 Serie s (e x cluding internal r echargeable baeries ) is warr anted to be fr ee fr om defectiv e w orkmanship and materials for a period o f two y ear s from date o f purchase . Internal rechar geable baeries ar e w arrant ed for 90 days. An y defe ...

  • Drive Medical Design 18605 - page 15

    DECLARA TION OF CONFORMITY M anufactur er: Driv e M edical D esign & M anufacturing 99 Seaview Boule v ard P ort W ashington, NY 11050 Pr oduct Designation : T ype/M odel: 1860 5 W e herewith declar e that the abo v e-mentioned product complie s with the requir ements of E C Dir ective 9 3/ 42/EEC and the follo wing: Class: II a, Rule 2 Quality ...

  • Drive Medical Design 18605 - page 16

    Driv e M edical De sign & M anufacturing 99 Seaview Boule v ard P ort W ashington, NY 11050 ...

Производитель Drive Medical Design Категория Oxygen Equipment

Документы, которые мы получаем от производителя устройства Drive Medical Design 18605 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Drive Medical Design
- инструкции обслуживания 18605
- паспорта изделия Drive Medical Design
- информационные брошюры
- энергетические этикетки Drive Medical Design 18605
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Drive Medical Design 18605.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Drive Medical Design 18605, инструкции обслуживания, короткие инструкции или инструкции пользователя Drive Medical Design 18605. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Drive Medical Design 18605.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Drive Medical Design 18605, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Drive Medical Design 18605 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Drive Medical Design 18605.

Полная инструкция обслуживания Drive Medical Design, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Drive Medical Design 18605 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Drive Medical Design 18605, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Drive Medical Design 18605, которое найдем в данном документе
3. Советы по использованию основных функций устройства Drive Medical Design 18605 - которые должны облегчить нам первые шаги во время использования Drive Medical Design 18605
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Drive Medical Design 18605
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Drive Medical Design 18605 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Drive Medical Design 18605?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Drive Medical Design 18605, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Drive Medical Design 18605 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)