Manual Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1

22 pages 2.01 mb
Download

Go to site of 22

Summary
  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 1

    1 #L010185 June 2007 MBC10SI1 Programmable Simple Indexer/Driver User’s Guide 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 2

    2 #L010185 June 2007 Introduction The MBC10SI1 is an low cost single axis step motor driver integrated with a programmable simple indexer. The MBC10SI1 microstep driver/pulse generator has an output current capability of 1.5A minimum to 10.0A maximum (peak rating). The MBC10SI1 driver operates with a DC voltage of 20VDC to 80VDC. The MBC10SI1’s i ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 3

    3 #L010185 June 2007 A) A Profile input is activated; Ramps up to max speed. B) No limit is active; Max speed is reached (keeps running at max speed). C) No limit is active; Internal counter signals to ramp down to base speed. D) Internal Counter is complete; Base speed is reached. Pulses stop. AB C Max Speed Base Speed Off Time Speed AB CD Max Spe ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 4

    4 #L010185 June 2007 LEDs When powered and operated properly, the status LED will be green. When a communication or program syntax error occurs, the LED will change to RED and an error code will be generated in the error code register. To read and clear the error with the software, click on the “Verify Parameters” button. To read and clear the ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 5

    5 #L010185 June 2007 Connector Description : 2 P r o t c e n n o C # n i P n o i t p i r c s e D 1) C D V 0 ( d n u o r G y l p p u S r e w o P 2) C D V 0 8 - C D V 0 2 ( t u p n I y l p p u S r e w o P 3) A ( 1 e s a h P r o t o M 4) A / ( 3 e s a h P r o t o M 5) B ( 2 e s a h P r o t o M 6) B / ( 4 e s a h P r o t o M 71 x e d n I 82 x e d n I 9 ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 6

    6 #L010185 June 2007 s t n e m e r i u q e R e g a t l o VC D V 0 8 - 0 2 ) 8 d n a 7 s n i P ( s t u p n I e l i f o r Pt r a t S) C D V 0 ( w o L ) n i P ( t u p n I n o i t c e r i D W C) n e p O ( h g i H W W C) C D V 0 ( w o L ) n i P ( t u p n I f f O / n O n O) n e p O ( h g i H f f O) C D V 0 ( w o L ) n i P ( t u p t u O y s u B f f O d n ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 7

    7 #L010185 June 2007 Wiring Diagrams Dimensions and Jumper/Potentiometer Locations ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 8

    8 #L010185 June 2007 Setting the Output Current The output current on the MBC10SI1 is set by the on-board potentiometer R29 (Refer to Dimensions/ Jumper and Potentiometer Locations). This current adjust potentiometer determines the per phase peak output current of the driver. This relationship between the output current and the potentiometer settin ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 9

    9 #L010185 June 2007 Step Motor Configurations Step motors can be configured as 4, 6, or 8 leads. Each configuration requires different currents. Refer to the lead configurations and the procedures to determine their output current. WARNING! Step motors will run hot even when configured correctly. Damage may occur to the motor if a higher than spec ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 10

    10 #L010185 June 2007 8 Lead Motors Series Connection: When configuring the motor windings in series, use the per phase (or unipolar) current rating to determine the current setting potentiometer value. Parallel Connection: When configuring the motor windings in parallel, multiply the per phase (or unipolar) current rating by 2.0 to determine the c ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 11

    11 #L010185 June 2007 Functions Hard Limit Switches: When a hard limit switch is encountered, the pulses will stop. Hard limits are intended as an emergency stop for your system. Soft Limit Switches: These switches cause the indexer to ramp down to the base speed and finish the index, unless encountering a hard limit switch. Profile Inputs: These i ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 12

    12 #L010185 June 2007 SMPG-SMSI Software The SMPG-SMSI software is a handy utility that supports Anaheim Automation’s programmable pulse generators and simple indexers. Connecting your PC to the MBC10SI1, via a USB cable, the software can easily perform the following tasks: • Exercise and monitor the MBC10SI1 • Directly communicate with the M ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 13

    13 #L010185 June 2007 “The Unit is Connected” / “The Unit is NOT Connected” On the right of the T oolbar , the user will find the communication status of the indexer . If communications is not established, please refer to the troubleshooting section. File Menu Setup Menu Ex t ie r a w t f o s N I W 0 1 G P M S e h t t i x E Ct c e n n o. r ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 14

    14 #L010185 June 2007 Program Window e l i f o r P n o i t o M2 r o , 1 s e l i f o r p n o i t o m t c e l e S l e c e D / l e c c A d n e S c e s / s p e t s ( . r e x e d n i e h t o t r e t e m a r a p n o i t a r e l e c e d & n o i t a r e l e c c a e h t d n e S 2 ) d e e p S e s a B d n e S ) c e s s / p e t s ( . r e x e d n i e h t o ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 15

    15 #L010185 June 2007 Direct mode is used to directly control the motion for real time movements through serial communication. The indexer has 14 commands which are easy to remember for direct movement of a step motor . COM Port Settings Baud Rate: 1 15200 Parity: None Data Bits: 8 Stop Bits: 1 Flow Control: Xon/Xoff Unit Selection In order to sele ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 16

    16 #L010185 June 2007 $ - Version Number Register Format : $ Description: This command requests the indexer to return the version number . ! - Error Codes Register Format : ! Description: This command requests the indexer to get the current error code and print it to the screen. +/- - Direction Format: + or - Description: This command sets the dire ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 17

    17 #L010185 June 2007 C - Current Reduce Option Format: C# - where # is 0 or 1 Description: This command enables the driver to reduce current after pulses are done being sent. A 1 will enable current reduction, and a 0 will disable current reduction. This value is saved in the EEProm for standalone use. G - Go Slew (Run) Format : G# - where # is th ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 18

    18 #L010185 June 2007 S - Stop Soft Format: S Description: This command will cause the indexer to ramp down to base speed and run until the index is complete or a hard limit is activated. It can only be used when the unit is indexing. T - Complete Time Format: T#_[value] - where # is the motion profile number 1 or 2 Sample: T1_100 Complete T ime of ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 19

    19 #L010185 June 2007 Visual Basic Direct Mode Programming Examples Example 1: This Example is for Axis=0, and Profile=1 DimConst DefaultT imeout As Single = 0.5 frmMain.MSComm1.Output = "@0A1_100000” & Chr$(13) ‘Set Acceleration Pause DefaultT imeout frmMain.MSComm1.Output = "@0B1_1000” & Chr$(13) ‘Set Base S peed Pause D ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 20

    20 #L010185 June 2007 Troubleshooting Problem: Can not establish communications with the indexer. Possible Solutions: 1) Make sure the indexer has power. Is the Green LED on. 2) Check USB connections. 3) Check for loose cable connection either on the indexer or COM Port. 4) W as the software and drivers installed successfully? 5) Go to Setup | Comm ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 21

    21 #L010185 June 2007 e d o C r o r r E e p y T n o i t p i r c s e D 1 w o l f r e v O e v e i c e R r o r r E r o r r e l a n r e t n i n a s i s i h T . r o r r e g n i v e i c e r a d a h s n o i t a c i n u m m o c l a i r e s e h T . r e t u p m o c e h t y b d e s u a c 2r o r r E e g n a R k c e h C . r o t a r e n e g e s l u p e h t o t t ...

  • Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - page 22

    22 #L010185 June 2007 Copyright Copyright 2005 by Anaheim Automation. All rights reserved. No part of this publication may be repro- duced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior ...

Manufacturer Anaheim Automation Category Computer Accessories

Documents that we receive from a manufacturer of a Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 can be divided into several groups. They are, among others:
- Anaheim Automation technical drawings
- PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 manuals
- Anaheim Automation product data sheets
- information booklets
- or energy labels Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1, service manual, brief instructions and user manuals Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1.

A complete manual for the device Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1.

A complete Anaheim Automation manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1, that we can find in the current document
3. Tips how to use the basic functions of the device Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 - which should help us in our first steps of using Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1?

Use the form below

If you did not solve your problem by using a manual Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1, ask a question using the form below. If a user had a similar problem with Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER C10SI1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)