    #L010068 #L010068 USER'S GUIDE MODEL MDM40001 MICROSTEP DRIVER ANAHEIM AUTOMATION 910 E. Orangefair Lane Anaheim, CA 92801 TEL (714) 992-6990 FAX (714) 992-0471 E-Mail: aamotion@aol.com COPYRIGHT Copyright 19 96 by Anaheim Automation. All rights reserved. No part of thi s publication ma y be reproduced, transmitted, transcribed, stored in a re ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 2

    #L010068 #L010068 1 2 TABLE OF CONTENTS INTRODUCTION PAGE INTRODUCTION ......................................... 2 ORDERING INFORMATION ................................ 3 DESCRIPTION .......................................... 4 DRIVER TERMINAL DESCRIPTION P1 ............... 4 DRIVER TERMINAL DESCRIPTION P2 ............... 5 WIRING DIAGRAM ......... ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 3

    #L010068 #L010068 3 4 4 Amp Microstep Driver MDM40001 (This Manual) 6 Amp Microstep Driver MDM60001 10 Amp Microstep Driver MDM10001 40VDC Power Supply PSA40V4A 65VDC Power Supply PSA65V5A 80VDC Power Supply PSA80V4A Shielded Motor Cable AA129010S ORDERING INFORMATION FOR ANAHEIM AUTOMATION PIN DESCRIPTIONS P1 MICROSTEP DRIVERS AND ACCESSORIES MDM4 ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 4

    #L010068 #L010068 5 6 PIN DESCRIPTIONS P2 TYPICAL HOOK-UPS FOR APPLICATION : Pin# Description 1 Reduction Adjust: Phase Current Reduction Input. A resistor between this pin and pin 2 (Connector P2, Current Adjust) will proportionately reduced the current in both windings (1 second after the last positive going edge of the step clock input). The amo ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 5

    #L010068 #L010068 7 8 SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS INPUT VOLTAGE +12 TO +48 VDC OUTPUT CURRENT 4 AMPS PEAK PLATE TEMPERATURE 70° C STORAGE TEMPERATURE 40° TO +125° C INPUT CURRENT (PINS 1, 2, 4, 5) 15 mA Max ELECTRICAL SPECIFICATIONS (TA=25 E E C, V+ = 40VDC) ITEM TEST MIN TYP MAX UNI CONDITION TS Input Voltage 12 24 40 V Phase Output ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 6

    #L010068 #L010068 9 10 DETERMINING OUTPUT CURRENT Reducing the output current in the MDM40001 can be accomplished by connecting an The output current for the motor used when mic rostepping is determined differently from automatical ly 1 second after the last positive going edge of the step clock input. Se e that of a half/full unipolar driver. In t ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 7

    #L010068 #L010068 11 12 STEP MOTOR CONFIGURATIONS 4 Lead Motors Step motors can be configured as 4, 6, or 8 leads. Each configuration requires different currents. Shown below are different lea d configurations and the procedures to determine their output current. 6 Lead Motors When configur ing a 6 lead motor in a half-coil configuration (connected ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 8

    #L010068 #L010068 13 14 CONNECTING THE STEP MOTOR Phase 1&3 of the Step Motor is connected between pins 7 and 8 on connector P2. Phase 2&4 of the Step Motor is connected between pins 5 and 6 on connector P2. Refer to Figure 1 for TYPICAL APPLICATION HOOK-UP NOT E : The physical direction of the motor with respect to the direction input wil ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 9

    #L010068 #L010068 15 16 MICROSTEP SELECTION FULLSTEP OUTPUT SIGNAL The number of microsteps per step is selected by switches 1, 2, 3, and 4 of the DI P The MDM40001 has an active LOW open drain output at Connector P1, Pin 7 labeled switch. Table 5 shows the standard resolution values along with the associated inputs ON F/S OUT. This o utput is TRUE ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 10

    #L010068 #L010068 17 18 TIMING FAULT PROTECTION The Direction and Microstep Resolu tion Select inputs are synchronized with the positive The MDM40001 is internally protected against over temperature and short circuits. going edge of the Step Clock inpu t. When the Step Clock input goes high, the Direction The over tem perature set point is between ...

  • Anaheim Automation MICROSTEP DRIVER MDM40001 - page 11

    #L010068 #L010068 19 TORQUE/SPEED CURVES TORQUE/SPEED CURVES ...

Manufacturer Anaheim Automation Category Home Theater Server

Documents that we receive from a manufacturer of a Anaheim Automation MICROSTEP DRIVER MDM40001 can be divided into several groups. They are, among others:
- Anaheim Automation technical drawings
- MICROSTEP DRIVER MDM40001 manuals
- Anaheim Automation product data sheets
- information booklets
- or energy labels Anaheim Automation MICROSTEP DRIVER MDM40001
All of them are important, but the most important information from the point of view of use of the device are in the user manual Anaheim Automation MICROSTEP DRIVER MDM40001.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Anaheim Automation MICROSTEP DRIVER MDM40001, service manual, brief instructions and user manuals Anaheim Automation MICROSTEP DRIVER MDM40001. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Anaheim Automation MICROSTEP DRIVER MDM40001.

A complete manual for the device Anaheim Automation MICROSTEP DRIVER MDM40001, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Anaheim Automation MICROSTEP DRIVER MDM40001 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Anaheim Automation MICROSTEP DRIVER MDM40001.

A complete Anaheim Automation manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Anaheim Automation MICROSTEP DRIVER MDM40001 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Anaheim Automation MICROSTEP DRIVER MDM40001, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Anaheim Automation MICROSTEP DRIVER MDM40001, that we can find in the current document
3. Tips how to use the basic functions of the device Anaheim Automation MICROSTEP DRIVER MDM40001 - which should help us in our first steps of using Anaheim Automation MICROSTEP DRIVER MDM40001
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Anaheim Automation MICROSTEP DRIVER MDM40001
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Anaheim Automation MICROSTEP DRIVER MDM40001 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Anaheim Automation MICROSTEP DRIVER MDM40001?

Use the form below

If you did not solve your problem by using a manual Anaheim Automation MICROSTEP DRIVER MDM40001, ask a question using the form below. If a user had a similar problem with Anaheim Automation MICROSTEP DRIVER MDM40001 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)