    For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. This replace is approved fo ...

  • FMI B42LI-M - page 2

    www .fmiproducts.com 1 15386-01D 2 SAFETY W ARNING: Do not install a re pl ace inse rt in thi s box unl es s the manufacturer's instructions with the insert specically state this replace ha s be en tested for use with this insert. FOR YOUR SAFETY • Do not store or use gasoline or any oth er ammable vapors or liquids in the vicini ...

  • FMI B42LI-M - page 3

    www .fmiproducts.com 1 15386-01D 3 SPECIFICA TIONS 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 3/4" AIR SP ACE BACK AND SIDES HEARTH EXTENSION 66" X 20" 12" EACH SIDE 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OU ...

  • FMI B42LI-M - page 4

    www .fmiproducts.com 1 15386-01D 4 FIREPLACE INST ALLA TION SELECTING LOCA TION T o det erm ine safes t and mos t efc ien t loca ti on for replace, you must take into consideratio n the following guidelines: 1. Locat ion must allow for prope r clearanc es (see Figures 1 and 2). 2. Consider a location where replace will not be affected by d ...

  • FMI B42LI-M - page 5

    www .fmiproducts.com 1 15386-01D 5 HEARTH EXTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets the following specications: a ...

  • FMI B42LI-M - page 6

    www .fmiproducts.com 1 15386-01D 6 FIREPLACE INST ALLA TION Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch-Electrical Bushing Electrical Housing Wire Nut (3x) (Not Supplied) Outer Wrapper of Fireplace Electrical Cover Plate and Electrical Bushing Fireplace ...

  • FMI B42LI-M - page 7

    www .fmiproducts.com 1 15386-01D 7 Figure 8 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN 42" Fireplace 37 1 / 2 " 12-8DM 12-8HT Pipe Section 10 5 / 8 " 18-8DM 18-8HT Pipe Section 16 5 / 8 " 24-8DM 24-8HT Pipe Section 23 5 / 8 " 36-8DM 36-8HT Pipe Section 34 5 / 8 " 48-8DM 48-8HT Pipe Section 46 5 / 8 " RT ...

  • FMI B42LI-M - page 8

    www .fmiproducts.com 1 15386-01D 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S-8DM Return Elbow ...

  • FMI B42LI-M - page 9

    www .fmiproducts.com 1 15386-01D 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH A B 48" 36" 24" 18" 12" 4 3 / 8 " 16 3 / 8 " ELBOW SET ONL Y 9 3 / 4 " 25 1 / 2 " 1 12 3 / 4 " 30 3 / 4 " 1 15" 34 3 / 4 " 1 18" 40" 1 ...

  • FMI B42LI-M - page 10

    www .fmiproducts.com 1 15386-01D 10 VENTING INST ALLA TION Continued Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45.0° 20 3 / 8 " V12F-8DM 4. Remove shingles around opening mea - sured. Cut out this section. 5 . Add next sections of pipe until end p ...

  • FMI B42LI-M - page 11

    www .fmiproducts.com 1 15386-01D 11 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - Storm Collar Chimney Pipe W aterproof Caulk Storm Collar Flashing Storm Collar Installation (SC1 or SC2) Place storm collar over pipe and slide down unt ...

  • FMI B42LI-M - page 12

    www .fmiproducts.com 1 15386-01D 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule 10 FOOT RULE All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above high est poi nt where it pass es throu gh roof and must be at least 2 feet above highest po ...

  • FMI B42LI-M - page 13

    www .fmiproducts.com 1 15386-01D 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make su ...

  • FMI B42LI-M - page 14

    www .fmiproducts.com 1 15386-01D 14 OPTIONAL GAS LINE INST ALLA TION Continued W ARNING: If the replace has been used for wood burn- ing, rebox and chimney must be cl eaned of soot, creosote an d ashes be a qualied chimney cleaner . Creosote will ignite if heavily heated. OPERA TION AND MAINTENANCE Figure 23 - Glass Doors Cleaning Glass C ...

  • FMI B42LI-M - page 15

    www .fmiproducts.com 1 15386-01D 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued DAMPER HANDLE OPERA TION Damper handle, which opens and closes damper blade, is located inside rebox at cen ter to ward s bac k w all (s ee Fi gure 24 ). Pushing handle back into keyway slot will free damper blade to automatically open. T ...

  • FMI B42LI-M - page 16

    www .fmiproducts.com 1 15386-01D 16 P ARTS WOOD BURNING FIREPLACE MODEL B42LI-M 1 1 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21 ...

  • FMI B42LI-M - page 17

    www .fmiproducts.com 1 15386-01D 17 P ARTS WOOD BURNING FIREPLACE MODEL B42LI-M This list contains replaceable parts used in your replace. When ordering parts, see Replace- ment Parts on page 18 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 ** Insulation Pan 1 2 ** Air Separator 1 3 ** Firebox T op 1 4 108302-01 Air Deector 1 5 ** Wra ...

  • FMI B42LI-M - page 18

    www .fmiproducts.com 1 15386-01D 18 ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ANTI-DRAFT SHIELD (Round T op T ermination Only) ADS-8DM 30° OFFSET AND RETURN 30E-8DM ADJUST ABLE HOOD Antique Brass Finish - GA6053 Black P ...

  • FMI B42LI-M - page 19

    www .fmiproducts.com 1 15386-01D 19 FIRESTOP SP ACER FS-8DM F AN KIT - BK3 BLOWER KIT - BK ROUND TOP TERMINA TIONS RT -8DM, RTL-8DM ROUND TOP TERMINA TIONS WITH SLIP SECTION RTT -8DM, RTTL-8DM OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KIT FOR FLOOR INST ALLA TION AK4F SQUARE CHASE-TOP TERMINA TION ET -8DM, ETO-8DM ECONO-TOP TE ...

  • FMI B42LI-M - page 20

    1 15386-01 Rev . D 06/10 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmipr oducts.com ...

Manufacturer FMI Category Indoor Fireplace

Documents that we receive from a manufacturer of a FMI B42LI-M can be divided into several groups. They are, among others:
- FMI technical drawings
- B42LI-M manuals
- FMI product data sheets
- information booklets
- or energy labels FMI B42LI-M
All of them are important, but the most important information from the point of view of use of the device are in the user manual FMI B42LI-M.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals FMI B42LI-M, service manual, brief instructions and user manuals FMI B42LI-M. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product FMI B42LI-M.

Similar manuals

A complete manual for the device FMI B42LI-M, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use FMI B42LI-M by users. Manuals are usually written by a technical writer, but in a language understandable to all users of FMI B42LI-M.

A complete FMI manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual FMI B42LI-M - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the FMI B42LI-M, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the FMI B42LI-M, that we can find in the current document
3. Tips how to use the basic functions of the device FMI B42LI-M - which should help us in our first steps of using FMI B42LI-M
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with FMI B42LI-M
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of FMI B42LI-M in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning FMI B42LI-M?

Use the form below

If you did not solve your problem by using a manual FMI B42LI-M, ask a question using the form below. If a user had a similar problem with FMI B42LI-M it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)