  • Unified Brands (2)HY-5G - page 1

    ✩ ✩ ✩ ✩ IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION ✩ ✩ ✩ ✩ KEEP FOR OPERATOR KEEP FOR OPERATOR KEEP FOR OPERATOR KEEP FOR OPERATOR ✩ ✩ ✩ ✩ IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION ✩ ✩ ✩ ✩ OPERA TOR MA NUA L OM-HY-5G Part Numbe ...

  • Unified Brands (2)HY-5G - page 2

    OM-HY-5G 2 IMPORTA NT — REA D FIRST — IMPORTA NT WA RNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUA LIFIED T O WORK W ITH ELECT RICITY A ND PLUM BING. IM PROPER INSTALLA TION CA N CAUSE INJURY TO PERSONNEL AND/OR DA M A GE T O T HE EQUIPMENT . T HE UNIT M UST BE INST A LLED IN ACCORDA NCE WIT H A PPLICABLE CODES. CA UT ION: SHIPPING STRAPS A ...

  • Unified Brands (2)HY-5G - page 3

    OM-HY-5G 3 Table of Contents O P E R A T O R W A R N I N G S .................................................................... 2 R E F E R E N C E S ............................................................................. 3 E Q U I P M E N T D E S C R I P T I O N ................................................................. 4 INSPECTION ...

  • Unified Brands (2)HY-5G - page 4

    OM-HY-5G 4 Equipment Descri ption Your Groen HY-5G or (2)HY-5G HyPerSteam Convection Steam er is designed to give years of service. It has a stainless s teel cavity (cooking cham ber) which is s erved by an independent atmos pheric st eam generator which is gas-heated. A powerful blower circ ulates the steam in the cavity to increase heating ef fic ...

  • Unified Brands (2)HY-5G - page 5

    OM-HY-5G 5 (2)HY-5GF The second water connec tion can reduce treate d wat er requirement s. Water Qua lity and Treatment It is essential to s upply the s team generator with water that will not form scale. Even though the s team generator/boiler is engineered to m inimize scale form ation, sc ale development depends on the hardness of y our w ater ...

  • Unified Brands (2)HY-5G - page 6

    OM-HY-5G 6 Installation and Start-Up WA RNING T HE UNI T MUST BE INSTALLED BY PERSONNEL WHO A RE QUALIFIED TO WORK W ITH GAS, ELE CTRI CITY AND PLUMBING. IMPROPER INST A LLATION CA N CAUSE INJURY TO PERSONNEL A ND/OR DA M A GE T O THE EQUIPM ENT . THE UNIT MUST BE INSTALLED IN A CCORDA NCE WIT H A PPLICABLE CODES . CA UT ION DO NOT INST A LL T HE U ...

  • Unified Brands (2)HY-5G - page 7

    OM-HY-5G 7 After the unit has been connected to the gas supply, all gas joints m ust be chec ked f or leak s. No flame should be used when checking for leaks. A thick soap solution or other suitable leak detec tor should be used. For a unit on cas ters, com plete connec tion to the gas supply wi th connectors that com ply w ith the standard f or co ...

  • Unified Brands (2)HY-5G - page 8

    OM-HY-5G 8 D. Drain Connec tion Steamer s m ust be leveled fr ont to back , or pitched to the rear ( max imum ¼ inch) by adjusting the bullet f eet on the stand. A 2 inch ID hose m ay be attached to the unit drain. It m ust be rated f or very hot w ater. WA RNING DO NOT CONNECT T HE UNIT DRA IN DIRECT LY TO T HE BUILDING DRA IN . Ensure that there ...

  • Unified Brands (2)HY-5G - page 9

    OM-HY-5G 9 Initial Sta rt-Up After the HY-5G Steam er has been installed, test it to ensure that the unit is oper ating correc tly . 1. Rem ove all literature and pack ing m aterials from the interior and ex terior of the unit. 2. Make s ure the water supply line is open. 3. Make s ure that the gas supply line is open and that the manual k nob on t ...

  • Unified Brands (2)HY-5G - page 10

    OM-HY-5G 10 Operati on WA RNING A NY POTENTIAL USER OF THE EQ UIPM E NT MUST BE TRAINED IN SA FE A ND CORRECT OPERATING PROCEDURES. A . Controls Operator c ontrols are on the f ront right of the unit. The HY-5G c ontrol panel has the following touch pads and indicator lights : ! The ON /OFF touch pad gets the Hy Per Steam ready for use, or shuts it ...

  • Unified Brands (2)HY-5G - page 11

    OM-HY-5G 11 The tim er is used in three way s : 1 In the OFF pos ition the steam generator stays at a low boil or “holding” tem perature. 2 W hen a cook time is set, the unit steam s until the timer runs down to OFF. At that time s team ing stops, a red light c omes on and a beeper sounds. 3 W ith the timer turned to the ON position, the unit s ...

  • Unified Brands (2)HY-5G - page 12

    OM-HY-5G 12 Cleaning To k eep your HY - 5G Steam er in proper work ing condition, use the f ollowing procedure to clean the unit. T his regular cleaning will reduce the ef for t required to clean the steam generator and cavity. A . Sugge sted T ools 1. Mild detergent 2. Stainless st eel exterior cleaner s uch as Zepper® 3. Steam gener ator de-lim ...

  • Unified Brands (2)HY-5G - page 13

    OM-HY-5G 13 Steam Gene rator and Cooking Chamber On a regularly scheduled basis , or if the SERVICE light is on, follow the sim ple de-lim ing ins tructions below. This proc edure should be f ollowed for each cavi ty. REM EM BER: DON’T A LLOW DE-LIMING A G ENTS T O M IX WIT H DE-GREASERS. a. Ensure that the unit is tur ned on. b. Set the timer to ...

  • Unified Brands (2)HY-5G - page 14

    OM-HY-5G 14 Maintenance The HY-5G Steam er is designed for m inim um maintenanc e, and no user adjus tments should be necessar y . Cer tain parts m ay need r eplacem ent after pr olonged use. If there is a need for s ervice, only author ized Groen representatives should perform the work . Al w a ys s upply water with a low mineral c ount that meets ...

  • Unified Brands (2)HY-5G - page 15

    OM-HY-5G 15 Parts List - HY -5G To order parts , contact your authorized Groen Servic e Agency. Supply the model des ignation, serial number, part description, par t number, quantity, and when applicable, v oltage and phase. Key Description New Key Description New 1 Right Side Panel 138532 13 Funnel, Delim e 106624 2 Door Ass y , Com plete 125922 1 ...

  • Unified Brands (2)HY-5G - page 16

    OM-HY-5G 16 Parts List - (2) HY-5G To order parts , contact your authorized Groen Servic e Agency. Supply the model des ignation, serial number, part description, par t number, quantity, and when applicable, v oltage and phase. Parts liste d below only apply to model (2) HY-5 G. Common pa rts are listed on page 15 . Key Description Part No. Key Des ...

  • Unified Brands (2)HY-5G - page 17

    OM-HY-5G 17 Electri cal Parts List - HY-5G To order parts , contact your authorized Groen Servic e Agency. Supply the model des ignation, serial number, part description, par t number, quantity, and when applicable, v oltage and phase. Key Description Part No. Key Description Part No. 1 Fuse, 3 Am p 077853 15 Gas Valve 099906 2 W ater Level Pr obes ...

  • Unified Brands (2)HY-5G - page 18

    OM-HY-5G 18 Parts List - HY -5G To order parts , contact your authorized Groen Servic e Agency. Supply the model des ignation, serial number, part description, par t number, quantity, and when applicable, v oltage and phase. Key Description Part No. Key Descript ion Part No. 1 Steam Generator 138521 13 Gask et 106232 2 Cavity 138549 14 Pres sure Re ...

  • Unified Brands (2)HY-5G - page 19

    OM-HY-5G 19 Electri cal Schematic - HY-5G A ll Voltages HY-5G Wiring Diagra m P/N 130396 Rev A ...

  • Unified Brands (2)HY-5G - page 20

    OM-HY-5G 20 Serv ice Log Model No. Serial No. Date Purchased Purchase Order No. Purchased From Location Date Installed For Serv ice Call Date Maint enance Performed Perfor m ed by ...

  • Unified Brands (2)HY-5G - page 21

    OM-HY-5G 21 NOTES: ...

  • Unified Brands (2)HY-5G - page 22

    OM-HY-5G 22 LIMITED W ARRANTY TO COMMERCIA L PURCHA SERS* (U.S. & Canadian Sales Only .) Groen warrants to original com m ercial purc haser/users that foodser vice equipm ent manuf actured by Groen (“G roen Equipment” ) (other than CapKold f oodservice equipment) s hall be free from defects in mater ial and workm anship for (12) twelve mont ...

  • Unified Brands (2)HY-5G - page 23

    OM-HY-5G 23 VII. THIS WA RRA NTY IS E XCLUSIV E A ND IS IN LI EU OF A LL OT HER WA RRA NTIES, EXPRESSED OR IMPL IED, INCLUDING A NY IMPL IED WA RRANTY OF M ERCHANTA BILIT Y OR FIT NESS FOR A PA RT IC UL AR P UR POSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED. THE REM EDIES DESCRIBED A BO VE A RE EXCLUSIVE A ND IN NO EVENT SHA L L G RO EN BE LIAB ...

  • Unified Brands (2)HY-5G - page 24

    1055 Mendell Dav is Drive Jack son, MS 39272 Telephone 601 372-3903 Fax 601 373-9587 www.groe n.com OM-HY-5G Revised 10/01 Part Number 138486 Rev B ...

Manufacturer Unified Brands Category Electric Heater

Documents that we receive from a manufacturer of a Unified Brands (2)HY-5G can be divided into several groups. They are, among others:
- Unified Brands technical drawings
- (2)HY-5G manuals
- Unified Brands product data sheets
- information booklets
- or energy labels Unified Brands (2)HY-5G
All of them are important, but the most important information from the point of view of use of the device are in the user manual Unified Brands (2)HY-5G.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Unified Brands (2)HY-5G, service manual, brief instructions and user manuals Unified Brands (2)HY-5G. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Unified Brands (2)HY-5G.

A complete manual for the device Unified Brands (2)HY-5G, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Unified Brands (2)HY-5G by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Unified Brands (2)HY-5G.

A complete Unified Brands manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Unified Brands (2)HY-5G - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Unified Brands (2)HY-5G, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Unified Brands (2)HY-5G, that we can find in the current document
3. Tips how to use the basic functions of the device Unified Brands (2)HY-5G - which should help us in our first steps of using Unified Brands (2)HY-5G
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Unified Brands (2)HY-5G
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Unified Brands (2)HY-5G in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Unified Brands (2)HY-5G?

Use the form below

If you did not solve your problem by using a manual Unified Brands (2)HY-5G, ask a question using the form below. If a user had a similar problem with Unified Brands (2)HY-5G it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)