  • Lincoln 1600 - page 1

    1600advsvc REV: 1/8/07 SER VICE MA NUAL (DOMESTIC ) IMPING ER CONVEYOR O VENS LOW PROFILE 1600 SERIES ADVANTAGE Lincoln Foo dservice Products, LLC 1111 North Hadley Road Fort W ayne, Indiana 46804 United States of America Phone : (800) 374 -3004 U.S. Fax: (888 ) 790-8193 • Int’l Fax: (260) 436 -0735 Technical Servi ce Hot Line (800) 6 78-95 11 ...

  • Lincoln 1600 - page 2

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 2 TABLE OF CONTENTS TABLE OF CO NTENT S................................. ......................................................................... ....................................2 SEQUENC E OF OPER ATIONS / 1600- 000-A , 1601- 000-A ...................................... ...

  • Lincoln 1600 - page 3

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 3 SEQUENCE OF OPERA TIONS / 1 600-000-A , 16 01-000-A MODEL 16 00-000-A / 12 0 VAC / 60 HZ / NATURAL G AS MODEL 16 01-000-A / 12 0 VAC / 60 HZ / L.P. GA S POW ER SUPPLY Electrical po wer to be sup plied to the o ven by a thre e conductor c ordset. Voltag e from the black cond ...

  • Lincoln 1600 - page 4

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 4 TROUBLESHOOTING GUIDE GAS OVEN S MODEL 16 00-000-A / NAT URAL GAS / 1 20 VAC / 6 0 HZ / 1 PHA SE MODEL 16 01-000-A / L. P. GAS / 120 V AC / 60 HZ / 1 PHASE NOT E: When checking c omponent s on left side of unit, be sure t o check for proper conn ections in po wer connector, ...

  • Lincoln 1600 - page 5

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 5 Cooling Fan(s ) 120 VAC shou ld be at the motor . If voltage is present , check motor for shorts, opens, or grounds. W ITH POW ER OFF: check for locked rotor. Gas Suppl y Check for adequate gas su pply and clos ed manua l gas valves. Also, check flexible gas li ne connectio ...

  • Lincoln 1600 - page 6

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 6 are no obstruc tions, replac e gas contr ol valves. Hot Surf ace Igniter The ignition c ontrol will k eep the gas c ontrol val ves energized for 6 sec onds. At the end o f 6 seconds , the hot surf ace igniter must sens e a flame, or , the ignition contr ol will go int o loc ...

  • Lincoln 1600 - page 7

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 7 Interm ittent Heating Therm al/Overload of Main Fan an d Burner Blower Motors The m ain fan motors and the burner bl ower motors are equipped with internal th erm al protection and will cease to operate if o verheating oc curs. As the m otors overheat and then cool, th is w ...

  • Lincoln 1600 - page 8

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 8 Power Supp ly Check power supply at the DC control b oard for the 12 0 VAC at board term inals L1 and L2. Motor Contro l Board Place the test m eter probes on t erm inals A+ and A-. (W ith speed pote ntiometer s et to m axi mum speed (Approxim ately 2 min.) T he meter readi ...

  • Lincoln 1600 - page 9

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 9 Display Tr ansformer Measure the trans former primar y for a nom inal 120 VAC in put, if voltage is n ot present, trace wiring b ack to the o ven power source. Me asure the seco ndary output, which will nor mall y be 12-15 VAC. Voltage acros s term inals 1 and 3 on t he tem ...

  • Lincoln 1600 - page 10

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 10 SCHEMATIC / 1600 -000-A, 1601-000- A ...

  • Lincoln 1600 - page 11

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 11 REMOVAL, INST ALLA TION & ADJUSTMENTS MODEL S ERIES 1600 ADVANTAGE C A UTION ! BEFORE R EMOVING OR I NSTALLING ANY COMPO NENT IN T HE IMPINGER OVEN BE SU RE TO DISC ONNECT EL ECTRICAL P OWER AND G AS SUPPL Y BURNER CO NTROL - HONEYWELL - REPL ACEMENT A. Rem ove appropr ...

  • Lincoln 1600 - page 12

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 12 D. Reassem ble in reverse or der and chec k s y stem oper ation. CONVEYOR CO NTROL BOARD - C ALIBRATION A. Connect digit al volt m eter to the hall effect s ensor. Black meter lead connected to black hall ef fect sens or lead, red m eter lead to white hall eff ect sensor l ...

  • Lincoln 1600 - page 13

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 13 GAS V A LVE, DU AL S A FETY - REPL A CEM ENT A. Rem ove appropriate contr ol box cover. B. Rem ove incoming gas l ine. C. Rem ove screws from incom ing nipple mounting br acket. D. Rem ove incoming nippl e. E. Rem ove bypass tube ass y. F. Disconnect pipe union. G. Disconn ...

  • Lincoln 1600 - page 14

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 14 E. Rem ove assembl y and repl ace m ain orifice. F. Reassem ble in reverse or der and chec k s y stem oper ation. NOT E: Check all gas line f ittings for le aks. TEM PERA TURE CONTR OL POTENT IOMETER - REPL A CEMENT A. Rem ove control box cover. B. Loosen sc rew and slide ...

  • Lincoln 1600 - page 15

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 15 REL A Y - REPL ACEMENT A. Rem ove control box cover. B. Rem ove wires from relay, note wire num bers and loca tion for reinsta llation. C. Rem ove two (2) screws f rom relay base and replace r elay. D. Reassem ble in reverse or der m aking sure wire co nnectors are prop er ...

  • Lincoln 1600 - page 16

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 16 COOLING FAN MOTO R - REPL A CEM ENT A. Rem ove appropriate contr ol box cover. B. Rem ove mounting scre ws. C. Unplug electr ical connector and rem ove fan motor as sembl y . D. Reassem ble in reverse or der and chec k s y stem oper ation. M A IN FAN M OTOR - REPLACEMENT A ...

  • Lincoln 1600 - page 17

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 17 It is poss ible to check a thermoc ouple with a proper ly calibrate d D.C. m illivolt meter. At 32° F, the millivolt re ading shou ld be 0.00. This can be chec ked by inserti ng the therm ocouple into an ice bath. The m illivolt reading at 7 2° F should be 1. 134. W hen ...

  • Lincoln 1600 - page 18

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 18 PARTS / GENER A L - 1600-0 00-A ADVANTAGE SERIES LETTER PART # DESCRIPT ION A 369110 Access W indow Assy B 369929 Window Retainer C 369926 Window Fram e, Bottom D 369925 Glass, Access W indow E 369927 Window Fram e, Top F 369930 Screw, 10- 32x1/4 G 369211 Thumb Scr ew H 36 ...

  • Lincoln 1600 - page 19

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 19 BLOW UP / GENERAL – 1600-000-A ADVANT A GE SERIES ...

  • Lincoln 1600 - page 20

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 20 PARTS / CONTROL B OX, RIGHT - 1600 -000-A , 1601-0 00-A LETTER P ART # DESCRIPT ION A 369158 Sprock et, 10 Tooth B 369705 T hermocouple C 369757 Main O rifice, Nat. 370279 Main O rifice, L.P. D 369398 Solen oid Valve E 369552 Hot Sur face Igniter F 369755 Venturi, Nat. 369 ...

  • Lincoln 1600 - page 21

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 21 BLOW UP / CONTROL BOX, RIGHT - 1600 -000-A , 1601-0 00-A ...

  • Lincoln 1600 - page 22

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 22 PARTS / CONTROL B OX, LEFT - 1600-00 0-A , 1601-0 00-A LETTER P ART # DESCRIPT ION A 369706 T hermocouple with Extension B 369507 T hermostat, Cooling Fan C 369431 T hermostat, Control Box Hi-Lim it D 369532 Ignitio n Control E 369531 T ransformer , Burner F 369012 Fus e h ...

  • Lincoln 1600 - page 23

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 23 BLOW UP / CONTROL BOX, LEFT - 1600-000- A , 1601-000 -A ...

  • Lincoln 1600 - page 24

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 24 PARTS / OVEN B A CK - 16 00-000-A - SERIES LETTER P ART # DESCRIPT ION A 369547 W ire Form Therm ostat Bulb B 369724 Fan, C lockwise Rotat ion C 369776 Fan S hroud D 369777 Stand-O ff E 369778 Rear W all Ass y. F 369761 Motor Mou nt G 369726 Motor, Main Fa n 120V 60 Hz H 1 ...

  • Lincoln 1600 - page 25

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 25 BLOW UP / OVEN BACK - 1600-000-A - SERIES ...

  • Lincoln 1600 - page 26

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 26 PARTS / CONVEYOR - 16 00-000-A - SERIES LETTER P ART # DESCRIPT ION 369830 Com plete Conve y or A 369816 Con veyor Belting 370092 Belt, 1 F oot Section B 369825 Reta ining Ring C 369813 Con veyor Bearing Block D 369314 Roll, Co nveyor, Notc hed E 369812 Con veyor Idler Sha ...

  • Lincoln 1600 - page 27

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 27 BLOW UP / CONVEYOR - 1600-000- A – SERIES ...

  • Lincoln 1600 - page 28

    Low Prof ile – 1600-000-A Advantage Series Service Manual – Dom estic 28 ...

Manufacturer Lincoln Category Double Oven

Documents that we receive from a manufacturer of a Lincoln 1600 can be divided into several groups. They are, among others:
- Lincoln technical drawings
- 1600 manuals
- Lincoln product data sheets
- information booklets
- or energy labels Lincoln 1600
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lincoln 1600.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lincoln 1600, service manual, brief instructions and user manuals Lincoln 1600. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lincoln 1600.

Similar manuals

A complete manual for the device Lincoln 1600, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lincoln 1600 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lincoln 1600.

A complete Lincoln manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lincoln 1600 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lincoln 1600, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lincoln 1600, that we can find in the current document
3. Tips how to use the basic functions of the device Lincoln 1600 - which should help us in our first steps of using Lincoln 1600
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lincoln 1600
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lincoln 1600 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lincoln 1600?

Use the form below

If you did not solve your problem by using a manual Lincoln 1600, ask a question using the form below. If a user had a similar problem with Lincoln 1600 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)