Manual Lincoln 3240-2

40 pages 1.45 mb
Download

Go to site of 40

Summary
  • Lincoln 3240-2 - page 1

    X2svcm anual REV: 12/7/0 5 SER VICE M ANU AL (DOMESTIC & INTE RN ATION A L) IMPING ER X2 OVENS WITH ANALOG CONTROLS MODEL 3240-2, 3262-2, 3270-2 Lincoln Foo dservice Products, Inc. 1111 North Hadley Road P.O. Box 1229 Fort W ayne, Indiana 46801-1229 Phone : (800) 374 -3004 • Fax: (260) 436 -0735 Technical Service Hot Line (800) 678-9 511 www. ...

  • Lincoln 3240-2 - page 2

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 2 SEQUENCE OF OPERATION IMPINGER X2 OVENS 3240-2* 120/230VA C 60 HZ. 1 PHASE 3240-2* 120/230VA C 60 HZ. 3 PHASE 3262-2* 120/230VA C 60 HZ. 1 PHASE 3262-2* 120/230VA C 60 HZ. 3 PHASE 3270-2* 120/230VA C 60 HZ. 1 PHASE 3270-2* 120/230VA C 60 HZ. 3 PHASE *NOTE: Model num ber ending in TS i ...

  • Lincoln 3240-2 - page 3

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 3 SEQUENCE OF OPERATION IMPINGER X2 OVENS 3240-2* 230VAC 50 HZ. 1 PHASE 3262-2* 230VAC 50 HZ. 1 PHASE 3270-2* 230VAC 50 HZ. 1 PHASE *NOTE: Model num ber ending in TS ind icates top belt is split bel t Model num ber ending in SB indica tes bottom belt is s plit belt Model num ber ending ...

  • Lincoln 3240-2 - page 4

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 4 SCHEMATI C DIAGRAM MODEL 3240 -2, 3262-2, 3270-2 60 HZ. ...

  • Lincoln 3240-2 - page 5

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 5 SCHEMATI C DIAGRAM MODEL 3240 -2, 3262-2, 3270-2 50 HZ. ...

  • Lincoln 3240-2 - page 6

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 6 TROUBLESHO OTING GUIDE 3240-2* 120/230VA C 60 HZ. 1 PHASE 3240-2* 120/230VA C 60 HZ. 3 PHASE 3262-2* 120/230VA C 60 HZ. 1 PHASE 3262-2* 120/230VA C 60 HZ. 3 PHASE 3270-2* 120/230VA C 60 HZ. 1 PHASE 3270-2* 120/230VA C 60 HZ. 3 PHASE *NOTE: Model num ber ending in TS ind icates top bel ...

  • Lincoln 3240-2 - page 7

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 7 bearings. R eplace bear ings as n eeded. Oven will not heat Gas suppl y Check for adequate gas s uppl y to oven. Manual gas s hut off valve Check to see that the m anual gas shut off valve is open. Also, c heck flexible gas line c onnection f or an y damage. Main fan m otor Check for ...

  • Lincoln 3240-2 - page 8

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 8 wiring bac k to the centrif ugal sw itch of the bur ner blower m otor. If voltage is prese nt, check for 24VAC at pins #3 and # 2 (pilot v alve). If voltage is not pr esent, replace burn er contro l. If the pilot valve is en ergized, check to see that the high voltage i gniter circ ui ...

  • Lincoln 3240-2 - page 9

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 9 Tem perature regulat ion valve If 120VAC is present on the elec tronic tem perature control, term inal #13 to n eutral, chec k f or voltage at temper ature regulatio n valve. If no voltage is pr esent, trace wiring back to electronic tem perature co ntrol. If voltage is pr esent, lis ...

  • Lincoln 3240-2 - page 10

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 10 assembl y. Check f or damaged or t orn belting . Check conveyor sh aft bearings for dam age or exces sive wear. Repair or rep lace conv eyor com ponents as n eeded. Conve yor speed var ying or intermittent Power supp ly Check for a stead y 120VAC supp ly to the co nveyor control. If ...

  • Lincoln 3240-2 - page 11

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 11 TROUBLESHO OTING GUIDE 3240-2* 230VAC 50 HZ. 1 PHASE 3262-2* 230VAC 50 HZ. 1 PHASE 3270-2* 230VAC 50 HZ. 1 PHASE *NOTE: Model num ber ending in TS ind icates top belt is split bel t Model num ber ending in SB indica tes bottom belt is s plit belt Model num ber ending in SS indica tes ...

  • Lincoln 3240-2 - page 12

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 12 Oven will not heat Gas suppl y Check for adequate gas s uppl y to oven. Manual gas s hut off valve Check to see that the m anual gas shut off valve is open. Also, c heck flexible gas line c onnection f or an y damage. Main fan m otor Check for main f an operation. If it is not operat ...

  • Lincoln 3240-2 - page 13

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 13 Burner contr ol Check for suppl y voltage at term inal #7 on burn er control. If no voltage is pr esent, tr ace wiring back to air pressure s witch. If volt age is prese nt, check for output voltage (af ter the 30 seco nd de lay) from terminal #8 on the burner con trol. If there is n ...

  • Lincoln 3240-2 - page 14

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 14 On at this t ime Electronic t emper ature control control at term inals #13 and #12. O f there is no voltage, trace wiring back to the burner s witch. Also ch eck for supply vo ltage to term inal #20 on t he electro nic temper ature control. If there is no v oltage at t erm inal #20, ...

  • Lincoln 3240-2 - page 15

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 15 switch as n eeded. Control, con veyor Check for suppl y voltage to conve yor contro l at term inals #1 (AC) and #2 (AC). If no voltage is present, trace wiring back to conveyor sw itch. If AC v oltage is present, ch eck for DC voltage outp ut at term inals #3 (A-) and #4 (A +). If th ...

  • Lincoln 3240-2 - page 16

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 16 REMOVAL, INST ALLA TIO N & ADJUSTMENTS IMPINGER X2 S ERIES OVENS CAUTION ! BEFORE R EMOVING O R INST ALLING AN Y COMPONE NT IN T HE IMPINGER X 2 OVEN BE SU RE TO D ISCONNECT ELECT RICAL POW ER AND GAS SUP PLY MOTO R, MAIN FAN - RE PLACEM ENT 1. Shut off power at m ain break er. 2 ...

  • Lincoln 3240-2 - page 17

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 17 9. Rem ove burner tube brac ket and Burner tube. To rem ove burner tube, Rem ove cap from idle end of Oven wall a nd remove burner tub e. 10. Measure distance f rom end of shaft to the co llar 11. of blower wheel. Loose n blower wheels fr om s haft. (1/4" allen s crews - use liq ...

  • Lincoln 3240-2 - page 18

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 18 RELAY, M AIN FAN, - R EPLACEM ENT 1. Shut off power at m ain break er. 2. Remove control box c over. 3. Disconnect all w iring from relay and m ark all wiring f or reassem bl y. 4. Remove m ain relay and over load protec tor. 5. Remove overload protector f rom m ain relay and m ount ...

  • Lincoln 3240-2 - page 19

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 19 4. Disconnect wiring f rom burner blower rel ay and m ark all wir ing for reassem bl y. 5. Remove two m ounting screws and rem ove burner b lower rel ay. 6. Reassemble in re verse order a nd chec k s ystem operation. BURNER CON TROL – R EPLACE MENT 1. Shut off power at m ain break ...

  • Lincoln 3240-2 - page 20

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 20 7. Press the “FUNC” k ey until t he displa y reads “Cnf ”. Shut off burner, rem ove contro l from the mounting b ase. Close t he Hairpin s witch on th e control a nd replac e the contr ol in the m ounting base. 8. Turn the burner on . Set ove n temperatur e to 500 ° F and ve ...

  • Lincoln 3240-2 - page 21

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 21 4. Disconnect all w iring from the temper ature regulati on valve a nd the m ain gas val ve. Mark all wiring for reassem bly. 5. Remove pilot tub e from gas valve. Disc onnect pipe unions at the burner and at the inlet side of t he m ain gas valve. Loos en pip e clamp and r emove va ...

  • Lincoln 3240-2 - page 22

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 22 HALL EFF ECT SENSO R – REPL ACEMENT 1. Shut off power at m ain break er. 2. Remove control box c over. 3. Disconnect all w iring from hall eff ect sensor and m ark all w iring for reas sem bly. 4. Remove m ounting nut and r emove hall effec t sensor and m agnet. 5. Reassemble in re ...

  • Lincoln 3240-2 - page 23

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 23 CONVEYOR CO NTRO L – PROGR AMMING 1. Determine which br and of m otor is connec ted to th e conve yor control. 2. Determine which t ype of dart c onve yor control is i nstalled in th e oven. L ooking at the face of the control, the old st yle control wil l have “up” and “do w ...

  • Lincoln 3240-2 - page 24

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 24 CONVEYOR CO NTRO L – PROGR AMMING – DAYTO N MOTO R, DIRECT DR IVE Jumper “DART” Conveyor contr ol with “U P”, “DOW N” and “ENT ER” k eys (NEW STYLE). 1. Remove control box c over. 2. Remove top cov er from conveyor contro l. Locate pr ogram jumper on con veyor con ...

  • Lincoln 3240-2 - page 25

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 25 CONVEYOR CO NTRO L – PROGR AMMING – DAYTO N MOTO R, RIGHT ANGLE DRIV E Jumper “DART” Conveyor contr ol with “U P”, “DOW N” and “ENT ER” k eys. 8. Remove control box c over. 9. Remove top cov er from conveyor contro l. Locate pr ogram jumper on con veyor control an ...

  • Lincoln 3240-2 - page 26

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 26 CONVEYOR CO NTRO L – PROGR AMMING – GLEASON AVERY MO TOR, D IRECT DRI VE Jumper “DART” Conveyor contr ol with “U P”, “DOW N” and “ENT ER” k eys. 15. Rem ove control box co ver. 16. Rem ove top cover f rom conve yor control. Loc ate program jum per on conve yor con ...

  • Lincoln 3240-2 - page 27

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 27 This page in tentionally left blank. ...

  • Lincoln 3240-2 - page 28

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 28 IMPINGER X2 OVENS GENERAL VIEW LETT ER PART NUM BER D ESCRIPTIO N A 9004415 Finger hous ing, bottom (3240), #5 left (3262, 3270) B 9004415 Finger hous ing, bottom (3240), #6 right (3262, 3270) C 9004422 Finger housing, m iddle (3240), #3 left (326 2, 3270) D 9004422 Finger housing, m ...

  • Lincoln 3240-2 - page 29

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 29 ...

  • Lincoln 3240-2 - page 30

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 30 IMPINGER X2 OVENS OVEN CAV ITY LETT ER PART NUM BER D ESCRIPTIO N A 9004435 Guard, shaf t – 3262 9004419 Guard, shaf t – 3270 B 4071215 Housing, blo wer C 100601417 Air return plate, ri ght – 3240, 3262 200601417 Air return p late, right – 3270 D 100601417 Air return plate, l ...

  • Lincoln 3240-2 - page 31

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 31 ...

  • Lincoln 3240-2 - page 32

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 32 IMPINGER X2 OVENS CONTROL BOX LETT ER PART NUM BER D ESCRIPTIO N A 508120EP Coupling w/sleeve B 100501329 Front cover –2 oven 100501327 Front cover – 2TS ove n (split bel t top) 100501326 Front cover – 2SB o ven (split be lt bottom ) 100501325 Front cover –2SS o ven (split be ...

  • Lincoln 3240-2 - page 33

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 33 ...

  • Lincoln 3240-2 - page 34

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 34 IMPINGER X2 OVENS BURNER/DRIVE END LETT ER PART NUM BER D ESCRIPTIO N A 7007124 Flange, burner B 3900 48 Heat slinger, 3240 390047 Heat slinger, 3 262, 32 70 C 5 07500 EP Bearing, drive end D 5 01260 EP Motor, burner bl ower E 501250-8EP Relay, tim e delay F 3695 31 Transform er, 120 ...

  • Lincoln 3240-2 - page 35

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 35 ...

  • Lincoln 3240-2 - page 36

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 36 IMPINGER X2 OVENS CONVEYOR, SING LE LETT ER PART NUM BER D ESCRIPTIO N A 100403103 Shelf, infeed s ide 100403101 Shelf, out t ake side B 100403107 Pan stop, zero stop C 10040710 Crum b pan (bottom conveyor on ly) D 369005 Connecting l ink E 100405831 100405810 100405830 Conve yor bel ...

  • Lincoln 3240-2 - page 37

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 37 ...

  • Lincoln 3240-2 - page 38

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 38 IMPINGER X2 OVENS CONVEYOR, DUAL BELT LETT ER PART NUM BER D ESCRIPTIO N A 100403103 Tak e off shelf, infeed s ide 100403101 Tak e off shelf, out tak e side B 100403107 Pan stop, zero stop C 100403710 Crumb pan (bott om c onveyor only) D 405 849-2E P Connecting l ink E 100405847 4058 ...

  • Lincoln 3240-2 - page 39

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 39 ...

  • Lincoln 3240-2 - page 40

    Impinger X 2 – Analog S ervice Ma nual – Dom & Int’l 40 ...

Manufacturer Lincoln Category Double Oven

Documents that we receive from a manufacturer of a Lincoln 3240-2 can be divided into several groups. They are, among others:
- Lincoln technical drawings
- 3240-2 manuals
- Lincoln product data sheets
- information booklets
- or energy labels Lincoln 3240-2
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lincoln 3240-2.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lincoln 3240-2, service manual, brief instructions and user manuals Lincoln 3240-2. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lincoln 3240-2.

Similar manuals

A complete manual for the device Lincoln 3240-2, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lincoln 3240-2 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lincoln 3240-2.

A complete Lincoln manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lincoln 3240-2 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lincoln 3240-2, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lincoln 3240-2, that we can find in the current document
3. Tips how to use the basic functions of the device Lincoln 3240-2 - which should help us in our first steps of using Lincoln 3240-2
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lincoln 3240-2
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lincoln 3240-2 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lincoln 3240-2?

Use the form below

If you did not solve your problem by using a manual Lincoln 3240-2, ask a question using the form below. If a user had a similar problem with Lincoln 3240-2 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)