  • FMI VFP18MV - page 1

    Save this manual for future reference. UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER ALSO DESIGN-CER TIFIED AS A VENTED DECORA TIVE APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANUAL LO PILOT OFF HI VFP18MV VFP24MV VFP30MV V ariable Manually- Controlled WARNING: If the information in this manual is not followed exactly, a fire or explosio ...

  • FMI VFP18MV - page 2

    2 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly. Get fresh ...

  • FMI VFP18MV - page 3

    3 105071 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Ember Master Front Logs PRODUCT FEA TURES UNP ACKING 1. Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by b urners. This could damage heater . Always handle base assembly by grate. 2. Remove all protective packaging ap- plied to logs and heat ...

  • FMI VFP18MV - page 4

    4 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Confined and Unconfined Space The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfin ...

  • FMI VFP18MV - page 5

    5 105071 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the ro ...

  • FMI VFP18MV - page 6

    6 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" ...

  • FMI VFP18MV - page 7

    7 105071 OWNER’S MANUAL INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall. INST ALLA TION WARNING: A qualified ser- vice person must install heater. Follow all local codes. WARNING: Before installing in a solid fuel bu ...

  • FMI VFP18MV - page 8

    8 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Heat Resistant Material (A) INST ALLA TION Continued Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace Noncombustible Requirements for Material Distance (A) Safe Installation 12" or more Noncombustible material OK. Between 8" and 12&qu ...

  • FMI VFP18MV - page 9

    9 105071 OWNER’S MANUAL Continued Figure 6 - Minimum Mantel Clearances Without Using Hood MANTEL CLEARANCES In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear- ances listed below, you will need a hood. Determining Minimum Mant ...

  • FMI VFP18MV - page 10

    10 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material. If your heater is a manually-controlled model, yo ...

  • FMI VFP18MV - page 11

    11 105071 OWNER’S MANUAL INST ALLA TION Continued Continued WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater ...

  • FMI VFP18MV - page 12

    12 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Pressure Testing gas Supply Piping system Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutof f valv e from gas sup- ply piping. Pressures in excess of 1/2 psig will damage heater reg ...

  • FMI VFP18MV - page 13

    13 105071 OWNER’S MANUAL WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury. INSTALLING LOGS INST ALLA TION Continued Bottom Middle Log (#2) Metal Post Metal Post Groove Groove Grate Figure 18 - Installing ...

  • FMI VFP18MV - page 14

    14 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. 4. W ait fi ve (5) minutes to clear out any gas. Then smell for gas, including near the floor . If you smell gas, STOP! F ollow “B” in the safety in- formation, column 1. If you don’ t smell gas, go to the next step. 5. Press in contr ol knob and turn coun- terclockw ...

  • FMI VFP18MV - page 15

    15 105071 OWNER’S MANUAL WARNING: Do not operate heater between locked positions. CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve. The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provid ...

  • FMI VFP18MV - page 16

    16 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burners, and cir- culating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied se ...

  • FMI VFP18MV - page 17

    17 105071 OWNER’S MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit ...

  • FMI VFP18MV - page 18

    18 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. TROUBLESHOOTING Continued OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Burner backfiring during combustion Yellow flame in front burner during burner combustion Slight smoke or odor during initial operati ...

  • FMI VFP18MV - page 19

    19 105071 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instructions. • If you canno ...

  • FMI VFP18MV - page 20

    20 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. ILLUSTRA TED PA R T S BREAKDOWN VFP18MV VFP24MV VFP30MV 17 19 18 25 24 20 20 26 27 28 6 7 27 27 24 9 8 10 11 12 14 21 22 26-1 26-2 23 6-1 6-2 13 15 16 4 5 3 2 1R 1L ...

  • FMI VFP18MV - page 21

    21 105071 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. P ARTS LIST VFP18MV VFP24MV VFP30MV KEY PART NUMBER FOR NO. VFP18MV VFP24MV VFP30MV DESCRIPTION QTY. 1L 105241-01 105241-02 105998-01 Left Front Log (#1L) 1 1R __ ...

  • FMI VFP18MV - page 22

    22 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call Fireplace Manufacturers Incorporated’s Parts Department at 1-800- 888-2050 for referral information. You can also write to the address listed on the back ...

  • FMI VFP18MV - page 23

    23 105071 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • FMI VFP18MV - page 24

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased LIMITED ...

Manufacturer FMI Category Gas Heater

Documents that we receive from a manufacturer of a FMI VFP18MV can be divided into several groups. They are, among others:
- FMI technical drawings
- VFP18MV manuals
- FMI product data sheets
- information booklets
- or energy labels FMI VFP18MV
All of them are important, but the most important information from the point of view of use of the device are in the user manual FMI VFP18MV.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals FMI VFP18MV, service manual, brief instructions and user manuals FMI VFP18MV. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product FMI VFP18MV.

Similar manuals

A complete manual for the device FMI VFP18MV, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use FMI VFP18MV by users. Manuals are usually written by a technical writer, but in a language understandable to all users of FMI VFP18MV.

A complete FMI manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual FMI VFP18MV - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the FMI VFP18MV, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the FMI VFP18MV, that we can find in the current document
3. Tips how to use the basic functions of the device FMI VFP18MV - which should help us in our first steps of using FMI VFP18MV
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with FMI VFP18MV
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of FMI VFP18MV in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning FMI VFP18MV?

Use the form below

If you did not solve your problem by using a manual FMI VFP18MV, ask a question using the form below. If a user had a similar problem with FMI VFP18MV it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)