Manual Siemens PCIL43

112 pages 2.84 mb
Download

Go to site of 112

Summary
  • Siemens PCIL43 - page 1

    SIMATIC Industrial PC SIM ATIC Rack PC IL 43 DOCUMENT A TION DOCUMENT A TION Rack PC IL 43 simatic Industrial PC Operating Instructions Edition 09/2005 ...

  • Siemens PCIL43 - page 2

    ...

  • Siemens PCIL43 - page 3

    Introduction 1 Safety information 2 Description 3 Deployment planning 4 Installation 5 Connecting 6 Commissioning 7 Integration 8 Functions 9 Expansions and configuration 10 Maintenance and service 11 Troubleshooting 12 Technical data 13 Dimensional drawings 14 Detailed descriptions 15 Appendix A ESD Guidelines B Abbreviations C SIMATIC Industrial ...

  • Siemens PCIL43 - page 4

    Safety Guidelines This manual contains notices y ou have to ob serve in order to en sur e your personal safety, as well as to prevent damage to property. The notices r eferring to your perso nal safe ty are highlighted in the manual by a sa fety alert symbol, notices referring only to property damage have no safety alert symbol. These notices sho w ...

  • Siemens PCIL43 - page 5

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 iii Table of contents 1 Introducti on ................................................. ............................................................... ............................. 1-1 1.1 Preface .................................................... ..................... ...

  • Siemens PCIL43 - page 6

    Table of contents SIMATIC Rack PC IL 43 iv Operating Instructions, Edition 09/2005, A5E00432875-01 9 Functi ons .................................................... ............................................................... ............................. 9-1 9.1 Overvi ew of the ........................................... ...................... ...

  • Siemens PCIL43 - page 7

    Table of contents SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 v 14 Dimensional drawi ngs ........................................ ............................................................... .................... 14-1 14.1 Dimensional drawing of the device ......................... ............................... ...

  • Siemens PCIL43 - page 8

    Table of contents SIMATIC Rack PC IL 43 vi Operating Instructions, Edition 09/2005, A5E00432875-01 ...

  • Siemens PCIL43 - page 9

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 1-1 Introduction 1 1.1 1.1 Preface Purpose of this document These operating instructions con tain all the information you n e ed for commissioning and using the SIMATIC Rack PC IL 43. It is intended both for programming and testing/debugging perso nnel who commission the ...

  • Siemens PCIL43 - page 10

    Introduction 1.2 Guide for the oper ating instruction s SIMATIC Rack PC IL 43 1-2 Operating Instructions, Edition 09/2005, A5E00432875-01 1.2 1.2 Guide for the operating instructions Contents format T able of Contents Table of Contents Organization of the documentation, including the index of pages and chapters Introduction Purpose, layout and desc ...

  • Siemens PCIL43 - page 11

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 2-1 Safety information 2 2.1 2.1 General safety instructions Caution Please observe the safety instr uctions on the back cover of thi s documentation. You should not expand your device un less you have read the relevant safety instructions. This device is compliant with t ...

  • Siemens PCIL43 - page 12

    Safety information 2.1 General safety instructions SIMATIC Rack PC IL 43 2-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Battery This device is equipped with a Lithium battery. Batteri es may o nly be replaced by qualified personnel. Caution There is the risk of an explosio n if the battery is not replace d as directed. Repla ce only wi ...

  • Siemens PCIL43 - page 13

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 3-1 Description 3 3.1 3.1 Overview The SIMATIC Rack PC IL 43 is a p owerful industrial PC in 19" ra ck format design (4HE). It is perfectly suited for high-perform ance industrial PC application s. • High-lev el perfo rmance • Attractive price ...

  • Siemens PCIL43 - page 14

    Description 3.2 Areas of application SIMATIC Rack PC IL 43 3-2 Operating Instructions, Edition 09/2005, A5E00432875-01 3.2 3.2 Areas of application The SIMATIC Rack PC IL 43 offe rs system integrators, cabinet de signers, system engineers and machine designers a 1 9" rack PC platform for high-performan ce IT applications on the control and cel ...

  • Siemens PCIL43 - page 15

    Description 3.4 Function SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 3-3 3.4 3.4 Function • Integrated, assigned monitoring function s – Fan speed (CPU, power supply a nd front fan) – Temperature (case, p rocessor) – Program execution (watch dog) • RAID1 for automatic data mirrori ng of two serial ATA har ...

  • Siemens PCIL43 - page 16

    Description 3.5 Features SIMATIC Rack PC IL 43 3-4 Operating Instructions, Edition 09/2005, A5E00432875-01 General features • in PCIe x16 slot (optional) PCIe x16 graphic card (dual head: 2x VGA), 64 MB RAM Up to 2048 x 1536 at 75 Hz / 32-bit color depth Interfaces Ethernet 10/100/10 00 M bps (RJ45) USB 4 x front, 2 x back; high-current Serial CO ...

  • Siemens PCIL43 - page 17

    Description 3.5 Features SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 3-5 Optional accessories Disk drives DVD ROM Read: DVD ROM: Single layer 16x, Dual Layer 8x DVD+R/RW, DVD-R/R W 8x, DVD-RAM 2x CD-ROM, CD-R 32x, CD-RW 20x DVD ROM/CD RW Read: DVD ROM: Single Layer 16x, Dual Layer 8x DVD-R/-RW/+R/+RW 8x CD-ROM 52x, ...

  • Siemens PCIL43 - page 18

    Description 3.6 Design SIMATIC Rack PC IL 43 3-6 Operating Instructions, Edition 09/2005, A5E00432875-01 3.6 3.6 Design 3.6.1 External structure Front view of the dev ice Pos Description (1) Front panel with aperture for ventilation of the device (filter mat and fan ar e located behind this front panel) (2) Option for installing DVD-ROM, DVD-ROM/CD ...

  • Siemens PCIL43 - page 19

    Description 3.6 Design SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 3-7 3.6.2 Operator controls Operator control on/off button Pos Description  (1) The on/off/reset buttons have three functions: - Switch on the PC (press briefly 1x) - Shut down the oper ating system and PC (press briefly 1x) - Switch off th ...

  • Siemens PCIL43 - page 20

    Description 3.6 Design SIMATIC Rack PC IL 43 3-8 Operating Instructions, Edition 09/2005, A5E00432875-01 3.6.3 Connecting elements Interfaces Layout of the interfaces on the rear of the device               Po ...

  • Siemens PCIL43 - page 21

    Description 3.6 Design SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 3-9 Power supply Position of the IEC power plug Description IEC power connector for the AC power supply to the dev ice. The maximum permitted power range is 120 V AC to 240 V AC 3.6.4 Status displays Status displays Display Meanin g LED Description ...

  • Siemens PCIL43 - page 22

    Description 3.6 Design SIMATIC Rack PC IL 43 3-10 Operating Instructions, Edition 09/2005, A5E00432875-01 ...

  • Siemens PCIL43 - page 23

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 4-1 Deployment planning 4 4.1 4.1 Transport Although the Rack PC has a rugged design, its internal compo nen ts are sensitive to severe vibrations or shock. You must t herefore protect the PC from sev ere mechanical stress when transporting it. You should always use the o ...

  • Siemens PCIL43 - page 24

    Deployment planning 4.2 Unpacking and checking the deli very unit SIMATIC Rack PC IL 43 4-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Noting the device identification data The device can identif ied uniquely with the help of these numbe rs in case of repairs or theft. Enter the following data in the table below: • Serial number: The ...

  • Siemens PCIL43 - page 25

    Deployment planning 4.3 Ambient and environmental conditions SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 4-3 4.3 4.3 Ambient and environmental conditions When you plan your project, you should make allowances for: • Note the climatic and mechanical environmental conditions speci fied in the technical data in your ...

  • Siemens PCIL43 - page 26

    Deployment planning 4.3 Ambient and environmental conditions SIMATIC Rack PC IL 43 4-4 Operating Instructions, Edition 09/2005, A5E00432875-01 ...

  • Siemens PCIL43 - page 27

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 5-1 Installation 5 5.1 5.1 Installing the device Possible areas of installation The device may be installed in control desks, switching cabinet s and 19`` rack systems, both horizontally and vertically. Possible mounting methods Options of mounting the device • Mounting ...

  • Siemens PCIL43 - page 28

    Installation 5.1 Installing the device SIMATIC Rack PC IL 43 5-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Note For vertical operation, install the devi ce on a horizontal meta l base and secure it against tipping. The following decide bases are available from Rittal f or this purpose: Rittal Type TE 7000.620, Rittal Ty pe VR 3861.580 ...

  • Siemens PCIL43 - page 29

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 6-1 Connecting 6 6.1 6.1 Connecting peripherals Note before connecting Notice Connect only I/O modules approved fo r industrial appl ications t o EN 61000-6-2:2001. Note Hot-plug I/O modules (USB) may b e connected while the PC is in operation. Caution I/O devices not cap ...

  • Siemens PCIL43 - page 30

    Connectin g 6.2 Connecting the device to power SIMATIC Rack PC IL 43 6-2 Operating Instructions, Edition 09/2005, A5E00432875-01 6.2 6.2 Connecting the device to power To be noted before you connect the device Note The long-range power supply mod ule is designed for operation on 100-240 networks. It is not necessary to adjust the voltage range. War ...

  • Siemens PCIL43 - page 31

    Connectin g 6.2 Connecting the device to power SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 6-3 Localized information Outside of the USA and Canada, operation on a 230 V power suppl y : This device is equipped with a s afety-tested power cord which m ay only be conne cted to grounded shockproof power out let. If you ...

  • Siemens PCIL43 - page 32

    Connectin g 6.2 Connecting the device to power SIMATIC Rack PC IL 43 6-4 Operating Instructions, Edition 09/2005, A5E00432875-01 Secure the power plug You can secure the po wer plug in order to avoid unintentional d isconne ction of the power cord. Steps in securing the power plug 1 Remove the fastening screw (1) on the power supply module. 2 Power ...

  • Siemens PCIL43 - page 33

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 7-1 Commissioning 7 7.1 7.1 Prerequisites for commissioning • Before you switch on the devic e, you should verify that the per ipherals are connected, i.e. the keyboard, mouse, mo nitor and the power suppl y. • The operating system of your dev ice is preinstalled on t ...

  • Siemens PCIL43 - page 34

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 7-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Switch off the device Note On a Windows platform, always shut down the PC by clicking Start > Close . Press the on/off button behind t he front panel door. The green power LED is switched off. Disconnect the mains conn ector to ...

  • Siemens PCIL43 - page 35

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 7-3 7.3.2 DVD burner The DVD burner drive is an opti onal feature. Recordi ng methods supported by the disk drive: Disc-at-once, Track-at-once, Session-at-onc e, Packet writing. C D-R, CD- RW , DVD+R, DVD-R, DVD-RW and DV D+RW and d ua ...

  • Siemens PCIL43 - page 36

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 7-4 Operating Instructions, Edition 09/2005, A5E00432875-01 7.3.3 Removable hard disks The removable disk racks c an al so be hot swapped in connection to RAID1. Replacing a hard disk Caution Hard drives may onl y be swapped out of the removable frames when the disks are inactive and the de ...

  • Siemens PCIL43 - page 37

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 7-5 7.3.4 RAID system This is a RAID1 system configur ation (mirroring with two hard d isks). This enables the system to continue to operate whe n there is a problem with a fa ulty hard drive or cable in a channel and therefore increas ...

  • Siemens PCIL43 - page 38

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 7-6 Operating Instructions, Edition 09/2005, A5E00432875-01 Functions for RAID system management The preinstalled software of the RAID system offers enhanced functions for using and managing the RAID system. It can be started via "Start > Progra ms > Intel Matrix storage manager. ...

  • Siemens PCIL43 - page 39

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 7-7 Comments about faults Notice Input delay Depending on the load on the pr ocessor and the hard disk activi ty at the time, the system may become briefly ove rloaded when a disk fails du e to the sync hronization process. In extreme ...

  • Siemens PCIL43 - page 40

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 7-8 Operating Instructions, Edition 09/2005, A5E00432875-01 The functioning drive can be localized by means of the followin g table.     RAID BIOS RAID Software SATA inte rface Install ation location Port 0 Device Port 0 SATA1 (1) Remov able frame 1 Port ...

  • Siemens PCIL43 - page 41

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 7-9 Please replace the faulty drive with a new one of the same t ype and capac ity. Notice You can exchange the drive without switching the device off (ho t swap) on device s with removable frames. For devices without remo vable frames ...

  • Siemens PCIL43 - page 42

    Commissioning 7.3 Notes on operation SIMATIC Rack PC IL 43 7-10 Operating Instructions, Edition 09/2005, A5E00432875-01 The command "Rebuild to this Hard drive" starts the syn chroniza tion of the RAID1 association. ...

  • Siemens PCIL43 - page 43

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 8-1 Integration 8 The following options are availa ble for the integration of the device in existing or planned system environments/net works: Ethernet The integrated Ethernet port (10/100/1000 Mbp s) can be used for communication and for data exchange with automation dev ...

  • Siemens PCIL43 - page 44

    Integration SIMATIC Rack PC IL 43 8-2 Operating Instructions, Edition 09/2005, A5E00432875-01 ...

  • Siemens PCIL43 - page 45

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 9-1 Functions 9 9.1 9.1 Overview of the following monitoring functions The individual functions are impleme nted: • Temperature monitoring an d over /under temperature indication • Watchdog • Fan monitoring Notice The "SystemGuard" and "DeskView" ...

  • Siemens PCIL43 - page 46

    Functions 9.3 Watchdog (WD) SIMATIC Rack PC IL 43 9-2 Operating Instructions, Edition 09/2005, A5E00432875-01 9.3 9.3 Watchdog (WD) function The watchdog monitors the program e xecution and reports a progr am crash to the user by means of various reactions . You can find additional information on the supplied " Documentat ion and Drivers" ...

  • Siemens PCIL43 - page 47

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 10-1 Expansions and configuration 10 10.1 10.1 Open the device Caution Work on the open device may onl y be carried out by authori zed and qualified personnel. The device must always be kept clos ed, otherwise device safety cann ot be ensured. Caution The device contains ...

  • Siemens PCIL43 - page 48

    Expansions and configuration 10.1 Open the device SIMATIC Rack PC IL 43 10-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Open the device Steps for opening the enc losure cover 1 Remove the mounting screws (1). 2 Lift up the lid from the back and remove it. ...

  • Siemens PCIL43 - page 49

    Expansions and configuration 10.1 Open the device SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 10-3 Steps for opening the dev ice front 1 Tilt the front door (1) forward.  2 Remove the fan cover (2).  ...

  • Siemens PCIL43 - page 50

    Expansions and configuration 10.2 Memory expan sion SIMATIC Rack PC IL 43 10-4 Operating Instructions, Edition 09/2005, A5E00432875-01 10.2 10.2 Memory expansion Memory expansion options The motherboard is equipped with fou r slots for memory modules. This allows you to expand the memory capacity of your Ra ck PC to a maximum of 4 GB. You will find ...

  • Siemens PCIL43 - page 51

    Expansions and configuration 10.3 Installing expansion cards SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 10-5 10.3.2 Installing an expansion module Preparation Isolate the device from mains Installing expansion modules Steps for installing an expansio n module: 1 Open the device. 2 Remove the fastening screws (1) a ...

  • Siemens PCIL43 - page 52

    Expansions and configuration 10.4 Installing disk drives SIMATIC Rack PC IL 43 10-6 Operating Instructions, Edition 09/2005, A5E00432875-01 10.4 10.4 Installing disk drives 10.4.1 Options of ins talling disk drives The driver carrier module consi s ts of a horizontal and vertical driver carrier. A DVD-ROM, DVD-ROM/CD-RW, DVD bur ner, floppy drive o ...

  • Siemens PCIL43 - page 53

    Expansions and configuration 10.4 Installing disk drives SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 10-7 Removing the drive carrier module The driver carrier module consi s ts of a horizontal and vertical driver carrier. Steps for removing the drive carrier m odule 1 Loosen the mounting screws of the drive carrier ...

  • Siemens PCIL43 - page 54

    Expansions and configuration 10.4 Installing disk drives SIMATIC Rack PC IL 43 10-8 Operating Instructions, Edition 09/2005, A5E00432875-01 Disk drive or removable disk rack installation Steps for installing a disk drive in a horizontal dr ive carrier 1 Slide the disk drive into the carrier from the front. 2 Remove any vertical driv e carrier The o ...

  • Siemens PCIL43 - page 55

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 11-1 Maintenance and service 11 11.1 11.1 Removing and installing hardware components 11.1.1 Repairs Carrying out repairs Only authorized personnel are permitted to repair the device. Warning Unauthorized openin g and improper rep airs on the device may res ult in substan ...

  • Siemens PCIL43 - page 56

    Maintenance and service 11.1 Removing and installi ng hardware compone nts SIMATIC Rack PC IL 43 11-2 Operating Instructions, Edition 09/2005, A5E00432875-01 11.1.2 Replacing the backup battery To be noted before you replace the battery Caution Risk of damage! The lithium battery may only be replaced with an identical battery or with a type recomme ...

  • Siemens PCIL43 - page 57

    Maintenance and service 11.1 Removing and insta lling hardware compone nts SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 11-3 11.1.3 Removing the power supply module Warning Only qualified personnel is authorized to exchange the powe r su pply module. Preparation 1. Unplug the device from mains a nd disconnect all ca ...

  • Siemens PCIL43 - page 58

    Maintenance and service 11.1 Removing and installi ng hardware compone nts SIMATIC Rack PC IL 43 11-4 Operating Instructions, Edition 09/2005, A5E00432875-01 11.1.4 Removing the motherboard Preparation 1. Unplug the device from mains a nd disconnect all cables. 2. Open the device. Removing the motherboard How to remove the mother board 1. Remov e a ...

  • Siemens PCIL43 - page 59

    Maintenance and service 11.1 Removing and insta lling hardware compone nts SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 11-5 11.1.5 Remove filter and device fan Preparing for equipment fan exchange Unplug the device from m ains. Remove filter and fan Filter meshes are available under the following ord er numbers: A5 ...

  • Siemens PCIL43 - page 60

    Maintenance and service 11.1 Removing and installi ng hardware compone nts SIMATIC Rack PC IL 43 11-6 Operating Instructions, Edition 09/2005, A5E00432875-01 Installing the fan Notice Always install a fan of the same type! Caution Ensure that the arrow on the fan points away from the fan bra ck et. 11.1.6 Processor replacement Caution The processor ...

  • Siemens PCIL43 - page 61

    Maintenance and service 11.1 Removing and insta lling hardware compone nts SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 11-7 How to remove the processor 4. Unlock the CPU so cket and lift off socket cover. 5. Remove processor. Additional instructions can be found in the supplied Do cumentat ion & Drivers CD in t ...

  • Siemens PCIL43 - page 62

    Maintenance and service 11.2 Reinstalling the software SIMATIC Rack PC IL 43 11-8 Operating Instructions, Edition 09/2005, A5E00432875-01 11.2 11.2 Reinstalling the software 11.2.1 General installation procedure In case of software errors, you c an reinstall your software usi ng the Re covery CD, the Documentation and Dri vers CD or the Restore DVD ...

  • Siemens PCIL43 - page 63

    Maintenance and service 11.2 Reinstalling the software SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 11-9 Caution With the option "Restore system partition only", all data on dr ive C: (System) will be deleted. All data, user settings a nd all authorizations or lice nse keys on drive C: will be lost in the ...

  • Siemens PCIL43 - page 64

    Maintenance and service 11.2 Reinstalling the software SIMATIC Rack PC IL 43 11-10 Operating Instructions, Edition 09/2005, A5E00432875-01 11.2.3.1 Setting up the partitions for Windows operating system s After you have installed a new hard disk, or if partitions are faulty, or when you wish to change the partitioning on your hard di sk, you need t ...

  • Siemens PCIL43 - page 65

    Maintenance and service 11.2 Reinstalling the software SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 11-11 Format primary partition 1. Boot from the Recovery CD to fo rmat the partitions. Follow t he screen instructions until the Recovery functions win dow is displayed. 2. Select "Start command prompt" in t ...

  • Siemens PCIL43 - page 66

    Maintenance and service 11.2 Reinstalling the software SIMATIC Rack PC IL 43 11-12 Operating Instructions, Edition 09/2005, A5E00432875-01 Note If you are using Microsoft Windows as a professional user, you should have the following manuals available (not sup plied): Microsoft Windows 2000 Profession al Resource Kit (MSPress No 27 4) or Microsoft W ...

  • Siemens PCIL43 - page 67

    Maintenance and service 11.2 Reinstalling the software SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 11-13 11.2.5 Language selection on Windo ws XP Professional and Window s Server 2003 The M ultilanguage U se r I nterface (MUI) allows you to s et up the Windows menus and dialogs for additional language s. The defaul ...

  • Siemens PCIL43 - page 68

    Maintenance and service 11.2 Reinstalling the software SIMATIC Rack PC IL 43 11-14 Operating Instructions, Edition 09/2005, A5E00432875-01 11.2.7 Installing the RA ID Controller software The procedure for inst alling the software c an be found in the u ser manual on the supplied "Documentation and Drivers" CD. 11.2.8 Installing bur ner or ...

  • Siemens PCIL43 - page 69

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 12-1 Troubleshooting 12 12.1 12.1 General problems This chapter provide s you with tips on how to localize and trou bleshoot frequent ly occurring problems. Problem Possible cause To correct or avoid error There is no power supply to the device. Check the power supply, th ...

  • Siemens PCIL43 - page 70

    Troubleshooting 12.2 Problems w hen using modu l es of third-par t y manufactu r ers SIMATIC Rack PC IL 43 12-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Problem Possible cause To correct or avoid error The USB ports are disabled in your BIOS. Use a different USB port or enable the port. USB 2.0 devic e connected but USB 2.0 is disabl ...

  • Siemens PCIL43 - page 71

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 13-1 Technical data 13 13.1 13.1 General specifications General techni cal data Order numbers 6AG4011-2...(for details, refer to the ordering documentation) Dimensions 430.4x177.4x444. 4 (WxHxD i n mm). Detailed dimensional specifications are found in the "Dimensiona ...

  • Siemens PCIL43 - page 72

    Technical data 13.1 General specifications SIMATIC Rack PC IL 43 13-2 Operating Instructions, Edition 09/2005, A5E00432875-01 General techni cal data Immunity to discharges of static electricity ± 4 kV contact dis charge; (acc ording to IEC 61000-4-2) ± 8 kV air discharge; (a ccording to IE C 61000-4-2) Immunity to RF interference 10 V/ m, 80-100 ...

  • Siemens PCIL43 - page 73

    Technical data 13.1 General specifications SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 13-3 General techni cal data max. permissible power consum ption PCIe x1 slot max. permissible power consum ption PCIe x16 slot Max. admissible power consu mption per PCI slot Max. accumulated power dissipation per PCI slot PCI m ...

  • Siemens PCIL43 - page 74

    Technical data 13.1 General specifications SIMATIC Rack PC IL 43 13-4 Operating Instructions, Edition 09/2005, A5E00432875-01 General techni cal data VGA internal PCIe x16 Dual Head optiona l 1x 15-pin Cannon connector 2x 15-pin Cannon connector Keyboard PS/2 keyboard Mouse PS/2 mouse port USB 6 channels (4 at back, 2 in front) high current, high s ...

  • Siemens PCIL43 - page 75

    Technical data 13.2 Power requirements of component s (maximum values) SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 13-5 13.2 13.2 Power requirements of components (maximum values) Standard system Component Voltage +5 V +3,3 V +12 V -12 V 5 Vaux FSC D2156-S motherboard with processor heat sink Intel Pentium 4 proces ...

  • Siemens PCIL43 - page 76

    Technical data 13.4 Technical data of the telescopic rail s SIMATIC Rack PC IL 43 13-6 Operating Instructions, Edition 09/2005, A5E00432875-01 13.4 13.4 Technical data of the telescopic rails Ultimate load per pair Minimum 30 kg Full extraction length Minimum 470 mm Rail thickness Maximum 9.7 mm Fixing screws M5 x 6 mm The mounting screws of the te ...

  • Siemens PCIL43 - page 77

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 14-1 Dimensional drawings 14 14.1 14.1 Dimensional drawing of the device 483 19.01 465.1 18.31 mm Inch Dimensions: 433.5 17.06 oben bei senkrechtem Einbau oben bei senkrechtem Einbau 6.94 176.5 4 101.6 19.39 492.54 17.68 449.04 Figure 14-1 Dimensional dr awing of the devi ...

  • Siemens PCIL43 - page 78

    Dimensional drawing s 14.2 Dimensional drawing for the use of telescopic rail s SIMATIC Rack PC IL 43 14-2 Operating Instructions, Edition 09/2005, A5E00432875-01 14.2 14.2 Dimensional drawing for the use of telescopic rails mm Inch Dimensions: Dimensions for telescopic rails by the company Rittal type 3659 Dimensions for telescopic rails by the co ...

  • Siemens PCIL43 - page 79

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 15-1 Detailed descriptions 15 15.1 15.1 Motherboard The motherboard consists of the process or and the chipset, four slots for memory modules, internal and external ports, the Flash BIOS and the backup batt ery. You will find a detailed descrip tion of the motherboard as ...

  • Siemens PCIL43 - page 80

    Detailed descriptions 15.3 BIOS Setup SIMATIC Rack PC IL 43 15-2 Operating Instructions, Edition 09/2005, A5E00432875-01 15.3 15.3 BIOS Setup You can configure the syst em f unctions and hardwa re configurati on in the BIOS. The factory BIOS settings of the Rack PC deviate from the defau lt BIOS settings as follows: Tab Option Setting Boot Options ...

  • Siemens PCIL43 - page 81

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 A-1 A Appendix A A.1 A.1 Guidelines and declarations Notes on the CE Label The following appl ies to the SIMATIC product d escribed in this docume ntation : EMC Guidelines This product fulfills t he requirements for t he EC directive ™89 /336/EEC Electromagnetic Compati ...

  • Siemens PCIL43 - page 82

    Appendix A.2 Certificates and appro vals SIMATIC Rack PC IL 43 A-2 Operating Instructions, Edition 09/2005, A5E00432875-01 A.2 A.2 Certificates and approvals DIN ISO 9001 certificate The quality assurance system for the entire product process (de velopment, production, and marketing) at Sieme ns fulfills the requirements of ISO 9001 (co rresponds t ...

  • Siemens PCIL43 - page 83

    Appendix A.2 Certificates and appro vals SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 A-3 EMC USA Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the lim its for a Class A digital device, pursuan t to Part 15 of the FCC Rules. T hese li ...

  • Siemens PCIL43 - page 84

    Appendix A.3 Service and support SIMATIC Rack PC IL 43 A-4 Operating Instructions, Edition 09/2005, A5E00432875-01 A.3 A.3 Service and support Further support If you have any further questions relating to the products desc ribed in this documentation, contact your local representati ve at the SIEMENS office nearest you. You can locate your contact ...

  • Siemens PCIL43 - page 85

    Appendix A.3 Service and support SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 A-5 Service & Support on the Internet In addition to our documentation servi ces, you can also make us e of all our online knowledge base on the Internet. http://www.siemens.com/asis There you find: • The Newsletter contains the late ...

  • Siemens PCIL43 - page 86

    Appendix A.4 Retrofitting instructions SIMATIC Rack PC IL 43 A-6 Operating Instructions, Edition 09/2005, A5E00432875-01 A.4 A.4 Retrofitting instructions Below you will find a descripti on of the permissible configurat ion versions of the Rack PC IL 43 with drives and pr ocesso rs, and the resultant ope rational conditions. Approved configuration ...

  • Siemens PCIL43 - page 87

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 B-1 B ESD Guidelines B B.1 B.1 ESD Guidelines What does ESD mean? All electronic modules are equipped with highly integ rated modu les or components. Based on their design, these electroni c components are highly sensiti ve to overvoltage and thus to discharge of static e ...

  • Siemens PCIL43 - page 88

    ESD Guidelines B.1 ESD Guidelines SIMATIC Rack PC IL 43 B-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Electrical charge Anyone who is not connected to t he electrical potential of thei r surroundings can be electrostatically charg ed. The figure below shows the maximum el ectrostatic voltages that can accumulate in a person who is ope ...

  • Siemens PCIL43 - page 89

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 C-1 C Abbreviations C C.1 C.1 Abbreviations Abbreviation T erm Definition AC Alternating current Alternating current ACPI Advanced Configurati on and Power Interface Configuration interfac e, all ows the operating system control over the power supply to al l devices conne ...

  • Siemens PCIL43 - page 90

    Abbreviation s C.1 Abbreviations SIMATIC Rack PC IL 43 C-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Abbreviation T erm Definition CGA Color Graphics Adapter S tandard monitor interface CLK Clock pulse Clock signal for controllers CMOS Complementar y Metal Oxide Semiconductors Complementary metal oxide semiconductors. Computer chips f ...

  • Siemens PCIL43 - page 91

    Abbreviation s C.1 Abbreviations SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 C-3 Abbreviation T erm Definition EIDE Enhanced Integr ated Drive El ectronics An enhancement of th e IDE standard. Enhanced IDE is the standard for a ha rdware interface. This interface is designed for disk drives operatin g with internal ...

  • Siemens PCIL43 - page 92

    Abbreviation s C.1 Abbreviations SIMATIC Rack PC IL 43 C-4 Operating Instructions, Edition 09/2005, A5E00432875-01 Abbreviation T erm Definition HW Hardware I/O Input/Output Data inpu t/output on computers IDE Integrated Device Electroni cs An interface for hard disk dr ives in which the controller electronics are locat ed on the drive itself. This ...

  • Siemens PCIL43 - page 93

    Abbreviation s C.1 Abbreviations SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 C-5 Abbreviation T erm Definition PATA Parallel ATA An interface for hard disk drive s and optical drives with parallel dat a transfer of up to 100 Mbps PC Personal Computer PCI Peripheral Component Interc onnect High-speed expansion bus P ...

  • Siemens PCIL43 - page 94

    Abbreviation s C.1 Abbreviations SIMATIC Rack PC IL 43 C-6 Operating Instructions, Edition 09/2005, A5E00432875-01 Abbreviation T erm Definition RxD Receive Data Data transfer signal SATA Serial ATA An interface fo r hard disk drive s and optical drives with serial data tr ansf er of up to 1.5 Mbps SCSI Small Computer System Interf ace Interface fo ...

  • Siemens PCIL43 - page 95

    Abbreviation s C.1 Abbreviations SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 C-7 Abbreviation T erm Definition VGA Video Graphics Array Video adapter which m eets industrial s tand ard; can be used for any commo nly avail able software VRM Voltage Regulator Module W2k W indows 2000 WAV Wave Length Encoding Lo ss-fr ...

  • Siemens PCIL43 - page 96

    Abbreviation s C.1 Abbreviations SIMATIC Rack PC IL 43 C-8 Operating Instructions, Edition 09/2005, A5E00432875-01 ...

  • Siemens PCIL43 - page 97

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 Glossary-1 Glossary Application An application is a program which builds directly on the MS-DOS / Windows operating system. Applications on your PG or PC, for exa mple, are STEP 7, STEP 7-Micro/WIN. ATAPI CD–ROM Drive AT -Bus A ttachment P acket I nterface (co nnected t ...

  • Siemens PCIL43 - page 98

    Glossary SIMATIC Rack PC IL 43 Glossary-2 Operating Instructions, Edition 09/2005, A5E00432875-01 BEEP code If the BIOS detects a boot error , it outputs an audible warning based on the current test result Boot diskette A diskette that contains a boot s ector and an initial loader fo r the operating system. This ca n be used to load the operating s ...

  • Siemens PCIL43 - page 99

    Glossary SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 Glossary-3 Controller Integrated hardware and software controllers that co ntrol the f unctions of certain internal or peripheral devices (f or examp le, the keyboard controller). Device configuration The configuration of a programming de vice contains informatio ...

  • Siemens PCIL43 - page 100

    Glossary SIMATIC Rack PC IL 43 Glossary-4 Operating Instructions, Edition 09/2005, A5E00432875-01 Ethernet Local network (bus structure) fo r text an d data communication w ith a transfer rate of 10 Mbps. Formatting Basic partitioning of memory sp ace on a magnetic d ata carrier i nto track and segments. Formatting deletes all data on a data carrie ...

  • Siemens PCIL43 - page 101

    Glossary SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 Glossary-5 IT networks Networks for I nformation t echnology LAN L ocal A rea N etwork is a local network that c onsists of a group of compute rs and other devices that are distributed acros s a relative ly restricted ran ge and are linked with communication cabl ...

  • Siemens PCIL43 - page 102

    Glossary SIMATIC Rack PC IL 43 Glossary-6 Operating Instructions, Edition 09/2005, A5E00432875-01 Motherboard The motherboard is the core of t he computer. Here, data are p ro cessed and stored, and interfaces and device I/Os are controlled and managed. Operating system Summarizing term describing all functio ns for program execution , allocation o ...

  • Siemens PCIL43 - page 103

    Glossary SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 Glossary-7 Pixel PixEl ement (picture point). The pixel represents the smallest elemen t that can be reproduced on-screen or on a printer. PROFIBUS / MPI Pro cess Fi eld Bus (standard bus system for proce ss applications) RAM The RAM is the total a read /write me ...

  • Siemens PCIL43 - page 104

    Glossary SIMATIC Rack PC IL 43 Glossary-8 Operating Instructions, Edition 09/2005, A5E00432875-01 Serial interface Data is transmitted one bit at a ti me via a serial port. They a re used in all applications requiring minimum wiri ng and data transfer acros s greater dista nces. Session at once In session at once, the CD can be written to both with ...

  • Siemens PCIL43 - page 105

    Glossary SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 Glossary-9 Windows Microsoft Windows is a multitaski ng graphical user interface. W indows provides a standard graphical interface based on drop-d own menus, windowed region s on the screen, and allows operation with a pointer device such as a mouse. WLAN W irele ...

  • Siemens PCIL43 - page 106

    Glossary SIMATIC Rack PC IL 43 Glossary-10 Operating Instructions, Edition 09/2005, A5E00432875-01 ...

  • Siemens PCIL43 - page 107

    SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 Index-1 Index 5 5.25" mounting bays, 10-6 A Abbreviations, C-1 Angle brackets, 5-1 Mounting methods, 5-1 Approvals, 4-3 Assignment Resources, 10-4 Authorization, 11-8 B Backup battery, 11-2 Removal, 11-2 Battery, 2-2 Battery replacement, 11-2 BIOS Setup, 11-2 Burner ...

  • Siemens PCIL43 - page 108

    Index SIMATIC Rack PC IL 43 Index-2 Operating Instructions, Edition 09/2005, A5E00432875-01 Fan screws, 11-5 Floppy disk, 13-3 Front drive bay, 10-6 Front view, 3-6 G Graphics, 13-3 Graphics Technical Data, 13-3 Guidelines ESD Guidelines, B-1 H Hard disk, 13-3 HD, 3-9 HD Status displays, 3-9 hexagonal bolts, 11-4 Hyper-T hreading, 3- 4 I Identifica ...

  • Siemens PCIL43 - page 109

    Index SIMATIC Rack PC IL 43 Operating Instructions, Edition 09/2005, A5E00432875-01 Index-3 P Partitioning Windows 2000, 11-10 Windows XP, 11-10 PCI/AT expansion cards, 10-4 Expansion, 10-4 Technical Data, 13-3 Peripherals, 6-1 Power Status displays, 3-9 POWER, 3-9 Power consumption, 13-1 Power re quirements , 13-5 Power supply, 3-4, 3-9, 6-2, 13-1 ...

  • Siemens PCIL43 - page 110

    Index SIMATIC Rack PC IL 43 Index-4 Operating Instructions, Edition 09/2005, A5E00432875-01 Unpacking Unpacking the device, 4-1 USB, 13-4 Interfaces, 3-4, 3-8 Technical Data, 13-4 V Ventilation slits, 4-3 VGA Interfaces, 3-4 W Warranty, 2-1 Watchdog, 9-2 Status displays, 3-9 Watchdog Monitoring function, 3-4, 9-2 Weight, 13-1 Windows 2000 Partition ...

  • Siemens PCIL43 - page 111

    ...

  • Siemens PCIL43 - page 112

    Siemens A G Automation and Driv es Industrial Aut omation Systems Postfach 4848 90437 NUERNBERG Federal Republic of German y www .siemens.de/automation ,'$( ...

Manufacturer Siemens Category Personal Computer

Documents that we receive from a manufacturer of a Siemens PCIL43 can be divided into several groups. They are, among others:
- Siemens technical drawings
- PCIL43 manuals
- Siemens product data sheets
- information booklets
- or energy labels Siemens PCIL43
All of them are important, but the most important information from the point of view of use of the device are in the user manual Siemens PCIL43.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Siemens PCIL43, service manual, brief instructions and user manuals Siemens PCIL43. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Siemens PCIL43.

A complete manual for the device Siemens PCIL43, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Siemens PCIL43 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Siemens PCIL43.

A complete Siemens manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Siemens PCIL43 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Siemens PCIL43, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Siemens PCIL43, that we can find in the current document
3. Tips how to use the basic functions of the device Siemens PCIL43 - which should help us in our first steps of using Siemens PCIL43
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Siemens PCIL43
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Siemens PCIL43 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Siemens PCIL43?

Use the form below

If you did not solve your problem by using a manual Siemens PCIL43, ask a question using the form below. If a user had a similar problem with Siemens PCIL43 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)