-
Spectra UL633-1 - page 1
G L 4 0 0 S e r i e s www .trimble.com T rimble Construction Division 5475 Kellenburger Road Dayton, Ohio 45424 USA +1-937-245-5600 Phone www .trimble.com User Guide Bedienungsanleitung Manuel de l´utilisateur Guida per l´uso Gúia del usuario Gebruikershandleiding Operatörshandbok Brugermanual Guia do Usuário Bruksanvisning Käyttäjän opas ? ...
-
Spectra UL633-1 - page 2
G L 4 0 0 S e r i e s www .trimble.com T rimble Construction Division 5475 Kellenburger Road Dayton, Ohio 45424 USA +1-937-245-5600 Phone www .trimble.com User Guide Bedienungsanleitung Manuel de l´utilisateur Guida per l´uso Gúia del usuario Gebruikershandleiding Operatörshandbok Brugermanual Guia do Usuário Bruksanvisning Käyttäjän opas ? ...
-
Spectra UL633-1 - page 3
Printed in Germany Q104735 Rev . A(01/12) Ser vice and Customer Advice North-Latin America T rimble Spectra Precision Division 8261 State Route 235 Dayton, Ohio 45424 U.S.A. +1 (888) 272-2433 (T oll Free in U.S.A.) +1-937-482-0030 Fax www .trimble.com www .spectraprecision.com www .spectra-productivity .com Africa & Middle East T rimble Export ...
-
Spectra UL633-1 - page 4
Printed in Germany Q104735 Rev . A(01/12) Ser vice and Customer Advice North-Latin America T rimble Spectra Precision Division 8261 State Route 235 Dayton, Ohio 45424 U.S.A. +1 (888) 272-2433 (T oll Free in U.S.A.) +1-937-482-0030 Fax www .trimble.com www .spectraprecision.com www .spectra-productivity .com Africa & Middle East T rimble Export ...
-
Spectra UL633-1 - page 5
Printed in Germany Q104735 Rev . A(01/12) Ser vice and Customer Advice North-Latin America T rimble Spectra Precision Division 8261 State Route 235 Dayton, Ohio 45424 U.S.A. +1 (888) 272-2433 (T oll Free in U.S.A.) +1-937-482-0030 Fax www .trimble.com www .spectraprecision.com www .spectra-productivity .com Africa & Middle East T rimble Export ...
-
Spectra UL633-1 - page 6
1 T ABLE OF CONTENTS Introduction 2 FOR YOUR SAFETY 2 COMPONENTS 2 How to use the Laser System 3 Powering the Laser 3 RC603 Radio/IR Remote Control 3 T urning On/Off the RC603 3 LASER SETUP 4 T urning On/Off the Laser 4 Features and functions 4 Standard Features 5 X-Y -Z-grade entering mode 5 Using the Rotation mode 6 Using the Scan mode 6 Manual m ...
-
Spectra UL633-1 - page 7
2 Introduction Thank you for choosing one of the Spectra Precision Lasers from the T rimble family of precision lasers. The universal laser is an easy-to-use tool that offers accurate horizontal, vertical and sloped laser reference up to 1300 ft (400 m) away using a receiver . The plumb beam can be detected automatically and manually using the addi ...
-
Spectra UL633-1 - page 8
3 HOW TO USE THE LASER SYSTEM POWERING THE LASER Batteries W ARNING Ni-MHbatteries maycontain smallamounts ofharmful substances.Be sure tocharge thebattery before using it for the rst time, and after not using it for an extended length of time. Cha ...
-
Spectra UL633-1 - page 9
4 LASER SETUP Position the laser horizontally (tripod mount and rubber feet downward!) on a stable platform, wall mount or tripod at the desired elevation. The laser recognizes automatically whether it is used horizontally or vertically when switched on. T urning On/Off the laser PressthepowerbuttontoturnOn/Offthelaser . ...
-
Spectra UL633-1 - page 10
5 Standard Features X-Y -Z-grade entering – Step and Go mode Quickly press and release button 2 startsthegradeenteringmode.Bothgradevalueswillbeshown. Press/releasebutton 1 a grade reverse Y Press/releasebutton 2 a grade reverse X Press/releasebutton 3 a return to the standard display Quickly ...
-
Spectra UL633-1 - page 11
6 Usebutton 1 or 2 (PlusorMinus)tosetthedesireddigit. Thelaserwillself-leveltotherequiredgradepositionafterconrmingthegradechangewithbutton 4 . Note: Thebubble symbolsatthe laser ’sLCDwillash untilthelaser hasbeen self-levele ...
-
Spectra UL633-1 - page 12
7 Special MENU Features Menu Functions (Radio controlled) Press and release button 1 attheStandardDisplaytoentertheMENU. The menu offers always only the features which can be selected depending on the setup (horizontal or vertical). The icon of the selected function will be highlighted. A down arrow at the ...
-
Spectra UL633-1 - page 13
8 Automatic PlaneLok mode The PlaneLok mode can be activated in horizontal and vertical automatic and manual mode. In PlaneLok mode when set up horizontal, the beam will be locked to a xed elevation point (up to 80 m (260 ft) located on one or bothaxesateac ...
-
Spectra UL633-1 - page 14
9 2. Attach the HL750 receiver to a grade rod. Check the laser ’s elevation next to the laser then position the receiveratthesecondpointWITHOUTchangingthereceiver’selevationontherod. 3. Usethesighting guideson thetop ...
-
Spectra UL633-1 - page 15
10 4.PressandreleasetheMENUbuttonattheStandardDisplayandselect AxisAlign. 5.Selectthedesiredaxisthenpressbutton 4 tostart AxisAlign. Note : Adjusting the receiver into the beam before starting the automatic Axis Alignment reduces ...
-
Spectra UL633-1 - page 16
11 Start Reference Check Before starting some grade work which is very sensitive an additional Reference Check can be started manually . Press and release the MENU button at the Standard Display and select ReferenceCheck. Pressing and releasing button 4 st ...
-
Spectra UL633-1 - page 17
12 The RC603 Service menu offers additional features: RF IR options Press and release button 4 toconrmtheselectionandselectoneofthefollowingoptions: RF On; IR auto => Radio on all times; IR will be activated automatically after radio connection has been lost. ...
-
Spectra UL633-1 - page 18
13 Z-axis Automatic Spot Lok Automatic SpotLok (like PlaneLok) can be used to align and hold the plumb beam automatically to the SF601’s centerpointandcontinuouslyadjustingtheZ-andX-axis untilexitingthismode. TheUL looksalwaystothe center? ...
-
Spectra UL633-1 - page 19
14 Line Scan Line Scan centers the rotor horizontally and can be used to align the plumb beam to a desired horizontalposition.Press andreleasethe MENUbuttonat theStandard Displayandselect Line Scan. Pressing and releasing button 4 activates the Line Scan mode while the rotor checks the limitsofthe? ...
-
Spectra UL633-1 - page 20
15 Pairing the transmitter with remote control The chain symbol at button 1 indicates the remote has never been paired before which means no radio connectivity is given. Pressing the pairing button 1 will initiatea pairing request.Thetransmitter has tobe in pairing mode as shown above. Note : Make sure t ...
-
Spectra UL633-1 - page 21
16 Grade Entry SelecttheGradeEntryiconandpressandreleasebutton 4 toopentheGradeEntrymenu. Buttons 6/7 canbeusedtotogglebetweenStepandGoandDigitSelect. Press and release button 4 toconrmtheselection. Step and Go Digit Select Grade Display Select? ...
-
Spectra UL633-1 - page 22
17 User Name Select the User name icon and press and release button 4 to open the User name menu. One row for typing names in big font (15) and one row in small font (18) for letters or numbers are available. Button 5 and 8 c ...
-
Spectra UL633-1 - page 23
18 CALIBRA TION Checking Calibration of the Y - and X-Axes 1. Set up the laser 30 m (100 ft) from a wall and allow it to level. 2. Set the grade to 0.000% in both axes. 3. Raise/lower the receiver until you get an on-grade reading for the +Y axis. Using the on-grade marking notch as a reference, make a mark on the wall. Note: For increased precisio ...
-
Spectra UL633-1 - page 24
19 T roubleshooting Any errormessage canbe deleted with ashort pressof button 4 (OK). The table shows the related description andpossiblesolutions.Thenextservicecentershouldbe contactedifadifferenterrormessageasshownat the table will be displayed. Error codes ...
-
Spectra UL633-1 - page 25
20 SF601 - User Guide SF601attachedtoagraderod using the standard receiver clamp Components SF601 SF601attachedtothe optional pipe laser target base 1. SF601 2. Slider 3. CenterHole 4. PowerButton 5. BubbleVial 6. BatteryLED 7. ModeLED 8. RedDirectionLEDs 9. IR? ...
-
Spectra UL633-1 - page 26
21 Powering the SF601 1. Open the battery door pulling the battery door latch. TheSF601willbeshippedwithalkalinebatteries. Rechargeablebatteriescanbeusedoptionalbutneedtobechargedexternally 2. Insert four AA batteries noting the plus (+) and minus ...
-
Spectra UL633-1 - page 27
22 Using SpotLok mode (like PlaneLok) aligns and holds the plumb beam automaticallytotheSF601centerpoint(bothaxes)untilexitingthismode. Automatic-Spot-Match: (like Gra de Match- two existing elevation points will be connected to measure the grade value between these two points) aligns the? ...
-
Spectra UL633-1 - page 28
23 PROTECTING THE UNIT Do not expose the unit to extreme temperatures or temperature changes (do not leave inside the car). The unit is very robust and can resist damage if dropped even from tripod height. Before continuing your work, always? ...
-
Spectra UL633-1 - page 29
24 TECHNICAL DA T A UL633 Leveling accuracy 1,3 : ±0.5mm/10m,1/16“@100ft,10arcseconds Grade accuracy 1,3 : ±1.0mm/10m,1/8“@100ft,20arcseconds Rotation: 0-900rpm Scanmode: 5presetsizes+variableadjustment Operational area 1,2 : a ...
-
Spectra UL633-1 - page 30
G L 4 0 0 S e r i e s www .trimble.com T rimble Construction Division 5475 Kellenburger Road Dayton, Ohio 45424 USA +1-937-245-5600 Phone www .trimble.com User Guide Bedienungsanleitung Manuel de l´utilisateur Guida per l´uso Gúia del usuario Gebruikershandleiding Operatörshandbok Brugermanual Guia do Usuário Bruksanvisning Käyttäjän opas ? ...
-
Spectra UL633-1 - page 31
25 DECLARA TION OF CONFORMITY Please disregard the declaration of conformity within the manual. Following is the valid declaration: We T rimble Kaiserslautern GmbH Declareunderoursoleresponsibilitythattheproducts UL633 and RC603/SF601 T o which this declaration relates is in conformity with the following standards: EN300 440 ...
Do you have a question concerning Spectra UL633-1?
Use the form below
If you did not solve your problem by using a manual Spectra UL633-1, ask a question using the form below. If a user had a similar problem with Spectra UL633-1 it is likely that he will want to share the way to solve it.