    Note: Blade sold separately . Visit our website at: http://www .harborfreight.com Email our technical support at: productsupport@harborfreight.com 10" SLIDING COMPOUND MITER SA W WITH LASER GUIDE SYSTEM REV 14i Owner ’ s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly , ope ...

  • Chicago Electric 61971 - page 2

    Page 2 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP T able of Contents Safety ......................................................... 2 Specifications ............................................. 7 Setup .......................................................... 8 Operation ................. ...

  • Chicago Electric 61971 - page 3

    Page 3 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP T able A: RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS (120 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25′ 50′ 100′ 150′ 0 – 6 18 16 16 14 6.1 – 10 18 16 14 12 10.1 – 12 16 16 14 12 12.1 – 16 14 12 Do ...

  • Chicago Electric 61971 - page 4

    Page 4 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Grounding Instructions TO PREVENT ELECTRIC SHOCK AND DEA TH FROM INCORRECT GROUNDING WIRE CONNECTION: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provi ...

  • Chicago Electric 61971 - page 5

    Page 5 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP 8. Return all guards to original position if any are moved during blade replacement. Check all guards for proper operation after service. 9. Always use blades with correct size and shape (diamond versus round) of arbor holes. Blades that do no ...

  • Chicago Electric 61971 - page 6

    Page 6 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP V ibration Safety This tool vibrates during use. Repeated or long-term exposure to vibration may cause temporary or permanent physical injury , particularly to the hands, arms and shoulders. T o reduce the risk of vibration-related injury: 1. ...

  • Chicago Electric 61971 - page 7

    Page 7 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Specifications Electrical Rating 120 V AC / 60 Hz / 15 A Motor No Load Speed 4800 RPM Arbor Diameter 5/8" Recommended Blade T ype General Purpose with Carbide T ips Maximum Blade Diameter 10" Positive T able Stops 0°, 15°, 22.5°, ...

  • Chicago Electric 61971 - page 8

    Page 8 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Setup - Before Use: Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TIO ...

  • Chicago Electric 61971 - page 9

    Page 9 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Bevel Angle Indicator Slide Lock Knob Fence T rigger Lock T rigger Lock T rigger Clamp Miter Lock Miter Knob Miter Scale Base T able Extension Kerf Board Description of Selected Functions Head Lockdown Pin: 2 3 1 Align pin with deep groove to ...

  • Chicago Electric 61971 - page 10

    Page 10 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Operating Instructions Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. T OOL SET UP TO PREVENT SERIOUS INJUR Y FROM ACCI ...

  • Chicago Electric 61971 - page 11

    Page 1 1 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Using the W orkpiece Extension Supports 1. The T able Extensions are inserted into each side of the Base, and locked in place using the Wing Screws. 2. When properly installed, the upper face of the T able Extensions are level with the T abl ...

  • Chicago Electric 61971 - page 12

    Page 12 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Using the Depth Stop If a kerfing or rabbet cut which does not cut through the workpiece is desired, use the Depth Stop Bolt to control the depth of the cut. W ARNING! Only adjust the front Depth Stop Bolt. The rear Bolt is used to prevent th ...

  • Chicago Electric 61971 - page 13

    Page 13 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP W orkpiece and Work Area Set Up 1. Designate a work area that is clean and well lit. The work area must not allow access by children or pets to prevent distraction and injury . 2. Route the power cord along a safe route to reach the work area ...

  • Chicago Electric 61971 - page 14

    Page 14 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Maintenance and Servicing Procedures not specifically explained in this manual must be performed only by a qualified technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch of the tool off and unplug the too ...

  • Chicago Electric 61971 - page 15

    Page 15 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Calibrating the Miter Angle Indicator After checking or adjusting the Fence to confirm that it is at 90º to the Blade, check the accuracy of the Miter Angle Indicator . 1. Loosen the screw holding the Angle Indicator in place. 2. Rotate it u ...

  • Chicago Electric 61971 - page 16

    Page 16 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP T roubleshooting Problem Possible Causes Likely Solutions T ool will not start 1. No power at outlet. 2. Cord not connected. 1. Check power at outlet. 2. Check that cord is plugged in. T ool operates sporadically or at low power 1. Low power ...

  • Chicago Electric 61971 - page 17

    Page 17 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Parts List and Diagram PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE P ARTS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONL Y . NEITHER THE MANUF ACTURER OR DISTRIBUTOR MAKES ANY ...

  • Chicago Electric 61971 - page 18

    Page 18 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Part Description Qty 75 Arbor Insert (sold separately) – 76 Inner Flange 1 77 M5 x 16 Cross Pan Head Screw 2 78 Bearing Cover 1 79 Spindle 1 80 Woodruf f Key 4 1 81 6023 Bearing 1 82 Bearing Housing 1 83 Large Gear 1 84 Ø17 Circlip 1 85 HK ...

  • Chicago Electric 61971 - page 19

    Page 19 For technical questions, please call 1-888-866-5797. Item 61971 SAFETY OPERA TION MAINTENANCE SETUP Assembly Diagram ...

  • Chicago Electric 61971 - page 20

    3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 9301 1 • 1-888-866-5797 Limited 90 Day W arranty Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of ...

Manufacturer Chicago Electric Category Saw

Documents that we receive from a manufacturer of a Chicago Electric 61971 can be divided into several groups. They are, among others:
- Chicago Electric technical drawings
- 61971 manuals
- Chicago Electric product data sheets
- information booklets
- or energy labels Chicago Electric 61971
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chicago Electric 61971.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chicago Electric 61971, service manual, brief instructions and user manuals Chicago Electric 61971. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chicago Electric 61971.

A complete manual for the device Chicago Electric 61971, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chicago Electric 61971 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chicago Electric 61971.

A complete Chicago Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chicago Electric 61971 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chicago Electric 61971, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chicago Electric 61971, that we can find in the current document
3. Tips how to use the basic functions of the device Chicago Electric 61971 - which should help us in our first steps of using Chicago Electric 61971
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chicago Electric 61971
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chicago Electric 61971 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chicago Electric 61971?

Use the form below

If you did not solve your problem by using a manual Chicago Electric 61971, ask a question using the form below. If a user had a similar problem with Chicago Electric 61971 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)