    SE95004 Rev . 4 Operators Manual Installation, Operation & Service Electric T able T op Kettles For units built after August 1999 MODELS: Single Kettles KET -3-T KET -6-T KET -12-T KET -20-T* T win Kettles TKET -3-T TKET -6-T TKET -12-T * Floor T ype Leg Mount 1333 East 179th S t., Cleveland, Ohio, U.S.A. 441 10 Phone: (216) 481-4900 Fax: (216) ...

  • Cleveland Range KET-3-T - page 2

    T ABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation . . . . . . . . . . . . ...

  • Cleveland Range KET-3-T - page 3

    1 GENERAL Installation of the kettle must be accomplished by qualified electrical installation personnel working to all applicable local and national codes. Improper installation of pr oduct could cause injur y or damage. This equipment is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, ...

  • Cleveland Range KET-3-T - page 4

    2 ASSEMBL Y T able-T op Models (3, 6 & 12 gallon) Base Mounting Diagram T able-top models (3, 6 & 12 gallon - single and twin) must be positioned on a firm, level stand, or existing counter top, and bolted in place. These models are supplied with four threaded mounting bushings welded to the underside of the base. An optional support stand ...

  • Cleveland Range KET-3-T - page 5

    3 W A TER The sealed jacket of the electric kettle is precharged with the corr ect amount of a water based formula, and therefore, no water connection is requir ed to the kettle jacket. The kettle can be equipped with optional hot and/or cold water faucet, requiring 1/2" copper tubing as supply lines. INST ALLA TION CHECKS Although the kettle ...

  • Cleveland Range KET-3-T - page 6

    4 6 5 4 3 2 1 7 OPERA TING INSTRUCTIONS General Parts Drawing ITEM # DESCRIPTION FUNCTION 1. Tilting Handle Used for tilting the kettle. 2. V acuum/Pressur e Gauge Indicate steam pressur e in PSI inside steam jacket as well as vacuum in inches of mercury . 3. Pressur e Relief V alve This valve is used to vent the kettle and in the unlikely event th ...

  • Cleveland Range KET-3-T - page 7

    5 OPERA TING THE KETTLE DO NO T LEAN ON OR PLA CE OBJECTS ON KETTLE LIP . SERIOUS INJUR Y COULD RESUL T IF KETTLE TIPPED O VER, SPILLING HO T CONTENTS. 1. Before turning kettle on, read the V acuum/Pressur e Gauge ( 2 ). The gauges needle should be in the green zone. If the needle is in the " VENT AIR " zone, refer to the Kettle V enting ...

  • Cleveland Range KET-3-T - page 8

    6 MARINE LOCK Y our unit is equipped with a marine lock to prevent accidental tilting. The following procedur e should be used to tilt the kettle. 1. Grasp the tilt handle. 2. Hold the latch down to unlock tilting mechanism. 3. Pull the handle to tilt kettle. 4. T o lock, return the kettle to its upright position and push handle back. NOTE: Inspect ...

  • Cleveland Range KET-3-T - page 9

    7 MARINE LOCK Use a small nylon bristle brush to remove food and debris from pivot point. If lock is still sticking have maintenance disassemble and clean pieces individually and reassemble. Disassembly 1. Disconnect power from kettle. 2. Remove console cover from top of kettle's console. 3. Remove locknut and lockwasher from inside console. 4 ...

  • Cleveland Range KET-3-T - page 10

    8 F AUCET ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 1. KE50825-2 3/4" Spout (KET -3/6/12/20-T) . . . . . . .1 KE50825-9 3/4" Spout (TKET -3/6/12-T) . . . . . . . . .1 2. F A95022 Retaining Ring . . . . . . . . . . . . . . . . . .1 3. F A05002-19 "O" Ring . . . . . . . . . . . . . . . . . . . . . . .1 4. KE51736 Long Fauce ...

  • Cleveland Range KET-3-T - page 11

    9 KETTLE BOTTOM & SIDE ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE50556-1 Probe, Low W ater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE51723 Safety V alve, 50 PSI, 1/2" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE52455 Bottom Cover Gasket, 3 gallon kettle . . . . . . ...

  • Cleveland Range KET-3-T - page 12

    10 2 3 4 5 1 CORD & PLUG OPTION ITEM NO . P ART NO . DESCRIPTION QTY . FOR KET -6-T (SW) (200-240V AC, 3PH, 50/60Hz 1. KE02113-1 Cord Plug Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE54819-1 Plug (30A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE5 ...

  • Cleveland Range KET-3-T - page 13

    11 CONSOLE COMPONENTS & MARINE LOCK 5 4 6 7 10 9 8 11 12 13 26 23 5 2 3 1 14 15 25 16 18 19 20 21 17 24 22 ...

  • Cleveland Range KET-3-T - page 14

    12 CONSOLE COMPONENTS & MARINE LOCK ITEM NO . P ART NO . DESCRIPTION QTY . Single / T win 1. SE00114 Potentiometer with ON/OFF Switch, c/w Item #2 . . . . . . . . . . . . . . . . . . . . . . 1 / 2 2. KE51005 Rubber Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 / 2 3. KE50569-1 Knob, Poten ...

  • Cleveland Range KET-3-T - page 15

    13 NOTE: Item # 14 to be tack welded flush outside in the gearbox housing (item #1 ). Do not damage the outside edges of the gearbox housing when tack welding. 1 14 2 2 3 7 8 7 9 3 5 6 20 19 22 23 21 25 10 11 4 12 13 16 15 12 24 18 17 TIL TING GEARBOX ASSEMBL Y (12 gallon kettle only) ITEM NO . P ART NO . DESCRIPTION QTY . 1.-16. KE02062-1 Tilting ...

  • Cleveland Range KET-3-T - page 16

    14 ELECTRICAL P ANEL ITEM NO . P ART NO . DESCRIPTION QTY . Single / T win 1. KE54761 T er minal Block Mounting Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 / 2 2. SK50055-1 T er minal Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 / 6 3. SK50054-2 T er minal Block End Anchor . . . . . ...

  • Cleveland Range KET-3-T - page 17

    15 Cleveland Range equipment requir es little preventative maintenance. We do however pr ovide the following chart as a guideline for inspection and maintenance to keep your unit functioning at 100%. INSPECTION AND MAINTENANCE CHECK LIST The following check should be completed every six months or more frequently if unit is in a high volume facility ...

  • Cleveland Range KET-3-T - page 18

    16 BEARING LUBRICA TING PROCEDURE 1. Remove console cover . 2. Loosen two Allen screws on locking ring. 3. Pull locking ring to center of trunnion. 5. Clean newly exposed sections of trunnion. 6. Grease trunnion between kettle and console. 7. Repack outer needle bearing. 8. Push kettle back in place. 10. Reinstall trunnion and lock collar . 11. Rep ...

  • Cleveland Range KET-3-T - page 19

    17 CALIBRA TING PROCEDURE 1. Insure the unit has a vacuum befor e you begin calibrating procedur es. If unit requires venting r efer to Kettle V enting Instructions on page 18 of this manual. 2. T ur n kettle ON and set temperatur e dial to 10 ( Max.). 3. Allow the unit to cycle twice. 4. Check temperature of the inner kettle surface with a digital ...

  • Cleveland Range KET-3-T - page 20

    3. Remove Guard Bracket (A). 4. Pull Pressur e Relief V alve (B) open to insure vessel is not pressurized. 5. Remove Pressur e Relief V alve (B). 6. Replace Pressur e Relief V alve (B) with Street Elbow (C). 7. Add distilled water (D) through the Str eet Elbow (C), using a funnel if necessary . Refer to Distilled W ater Requirements chart for the p ...

  • Cleveland Range KET-3-T - page 21

    MARINE LOCK TESTING PROCEDURE 1. Check that lock clears stop pin on side box without rubbing when kettle is tilted (Figure A ). 2. Check side to side play . Lock should remain fully over stop pin when pushed to it's maximum side to side play (Figure B ). 3. Check that the kettle when pushed fully upright moves the lock to a closed position. T ...

  • Cleveland Range KET-3-T - page 22

    20 Fault Isolation Pr ocedur e Step T est 1. Is there pr oper incoming voltage at terminal block? 2. Is the red LED illuminated? 3. Is the green LED illuminated? 4. Do both contactors energize? 5. Measure continuity acr oss safety thermostat. Is it an open circuit? 6. Is there 120 V AC present acr oss the coils of the contactors? 7. Remove wire fr ...

  • Cleveland Range KET-3-T - page 23

    21 Fault Isolation Pr ocedur e Step T est 1. In a cold state, does the pressur e gauge read in the gr een zone? 2. Do the contactors shut off too early? (before r eaching nor mal maximum operating pressur e.) 3. Does the green LED r emain illuminated after the contactors shut off? 4. Unplug control box and measur e the resistance acr oss potentiome ...

  • Cleveland Range KET-3-T - page 24

    22 5. Remove kettle thermistor and allow to cool. Remove edge connector from control box. T est resistance acr oss edge connector's pins #2 and #7. Is it approximately 100,000 ohms? 6. T urn the potentiometer on the control box clockwise to increase the maximum operating temperature. Does the kettle now achieve maximum operating pressur e of 3 ...

  • Cleveland Range KET-3-T - page 25

    23 WIRING DIAGRAM 3 Gallon Kettles 200-240v Single Phase Only 380-480v Single Phase Only ...

  • Cleveland Range KET-3-T - page 26

    24 WIRING DIAGRAM 6-20 Gallon 200-240v 380-600v ...

  • Cleveland Range KET-3-T - page 27

    25 25 ON MARCHE ENCENDIDO ACCESO AN P AUSE, INTERRUPTION P AUSE, INTERRUPTION P AUSA, INTERRUPCION P AUSA, INTERRUZIONE P AUSE, UNTERBRECHUNG RESET R É ENCLENCHER RECONECT AR RESET NULLSTELLEN STOP OF ACTION ARR Ê T DE L'ACTION P ARAR FUNCIONAMIENTO ARRESTO OPERAZIONE FUNKTION STOPPEN F AST STOP , EMERGENCY ARR Ê T RAPIDE D'URGENCE P A ...

  • Cleveland Range KET-3-T - page 28

    26 26 LOW W A TER NIVEAU BAS DE L'EAU NIVEL DE AGUA BAJO LIVELLO BASSO W ASSERST AND NIEDRIG IGNITION F AILURE P ANNE D'ALLUMAGE F ALLO DE ENCENDIDO MANCA T A ACCENSIONE Z Ü NDUNGSFEHLER COOLING REFROIDISSEMENT REFRIGERACION RAFFREDDAMENTO K Ü HLUNG MIXER BRIDGE PONT DU M É LANGEUR PUENTE DE MEZCLADORA MENSOLA MESCOLA TORE MISCHER-BR ? ...

Manufacturer Cleveland Range Category Hot Beverage Maker

Documents that we receive from a manufacturer of a Cleveland Range KET-3-T can be divided into several groups. They are, among others:
- Cleveland Range technical drawings
- KET-3-T manuals
- Cleveland Range product data sheets
- information booklets
- or energy labels Cleveland Range KET-3-T
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cleveland Range KET-3-T.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cleveland Range KET-3-T, service manual, brief instructions and user manuals Cleveland Range KET-3-T. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cleveland Range KET-3-T.

A complete manual for the device Cleveland Range KET-3-T, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cleveland Range KET-3-T by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cleveland Range KET-3-T.

A complete Cleveland Range manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cleveland Range KET-3-T - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cleveland Range KET-3-T, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cleveland Range KET-3-T, that we can find in the current document
3. Tips how to use the basic functions of the device Cleveland Range KET-3-T - which should help us in our first steps of using Cleveland Range KET-3-T
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cleveland Range KET-3-T
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cleveland Range KET-3-T in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cleveland Range KET-3-T?

Use the form below

If you did not solve your problem by using a manual Cleveland Range KET-3-T, ask a question using the form below. If a user had a similar problem with Cleveland Range KET-3-T it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)