  • Chicago Electric 99702 - page 1

    AIRLESS P AINT SPRA Y MACHINE 99702 SET UP AND OPERA TING INSTRUCTIONS Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2 ...

  • Chicago Electric 99702 - page 2

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 2 SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if produc ...

  • Chicago Electric 99702 - page 3

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 3 plugs with grounded power tools. Unmodied plugs and matching out - lets will reduce risk of electric shock. Do not expose power tools to rain b. or wet conditions. Water entering a power tool will increase the risk of electric shock. Do not abuse the cord. Never use c. the cor ...

  • Chicago Electric 99702 - page 4

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 4 ries, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool ac - cidentally . Store idle power tools out of the d. reach of children and do not allow persons unfamiliar with the power tool or these instructions to oper- ate the power t ...

  • Chicago Electric 99702 - page 5

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 5   grounded. Ground Fault Circuit Inter- rupter (GFCI) should also be imple- mented – it prevents sustained elec- trical shock. W ARNING: The brass components 1 1. of this produ ...

  • Chicago Electric 99702 - page 6

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 6 Use tools with the lowest vibration 4. when there is a choice between dif- ferent processes. Include vibration-free periods each 5. day of work. Grip tool as lightly as possible (while 6. ? ...

  • Chicago Electric 99702 - page 7

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 7 Double Insulated T ools: T ools with T wo Prong Plugs T ools marked “Double Insulated” do 1. not require grounding. They have a special double insulation system   and complies w ...

  • Chicago Electric 99702 - page 8

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 8 RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25’ 50’ 75’ 100’ 150’ 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 – 12.0 18 14 ...

  • Chicago Electric 99702 - page 9

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 9 SPECIFICA TIONS Electrical Requirements 120 V~ / 60 Hz / 7.5 A Motor 3/4 HP Operating PSI 2350 – 2650 psi Paint Flow 0.33 GPM Fuse Class F , F10A/250 V Hose Size 1/4” Oil Requirement Hydraulic Oil UNP ACKING When unpacking, make sure that the item is intact and undamaged. If ...

  • Chicago Electric 99702 - page 10

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 10 Remove plastic cap and thread the 4. pressure hose onto the hose spray port and secure. Hose connected to spray port Power Switch 5. Remove the plastic cap on the end of the spray gun and thread the other end of the hose onto it. Remove the plastic cap from gun tip. Gun connecte ...

  • Chicago Electric 99702 - page 11

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 1 1 W ork Piece and W ork Area Set Up Designate a work area that is clean 1. and well-lit. The work area must not allow access by children or pets to prevent injury and distraction. Route the power cord along a safe 2. route to reach the work area without creating a tripping hazard ...

  • Chicago Electric 99702 - page 12

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 12 Allow the unit to draw paint until all air 10. and impurities are cleansed from the system and the paint runs pure. T urn the power Switch to its “OFF” 1 1. position and secure the return tube in its normal operating position. Purge and prime the Hose: Do not attach the Spra ...

  • Chicago Electric 99702 - page 13

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 13 Adjust the pressure control dial until 23. a solid coat of paint of desired thick- ness is achieved. Painting T ips: 24. Spray 10 to 12 inches from the  surface. Begin moving the Gun before  squeezing the T rigger . Release the T rigger before ending  the strok ...

  • Chicago Electric 99702 - page 14

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 14 MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch of the tool to its “OFF” position and unplug the tool from its e ...

  • Chicago Electric 99702 - page 15

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 15   T urn the power switch Off and un- o. plug the Sprayer . Remove the Gun from the hose. p. ? ...

  • Chicago Electric 99702 - page 16

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 16 T roubleshooting Problem Possible Causes Likely Solutions Sprayer will not start No power at outlet. 1. Cord not connected. 2. Sprayer turned off under 3. pressure. Check power at outlet. 1. Check that cord is plugged in. 2. T urn pressure control knob to maximum, or 3. PRIME/SP ...

  • Chicago Electric 99702 - page 17

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 17 PUMP P ARTS LIST Part Description Qty 1 Housing 1 2 Rocker 1 3 Inlet V alve Assembly 1 4 Retaining Ring 1 5 Pin 1 6 W asher 1 7 Screw 1 8 Nut 1 8.1 Bush 1 9 W asher 1 10 T op Seal 1 10.1 T op Seal Spring 1 11 Nut 1 12 Ball 1 13 Priming Plunger 1 14 Circle Ring 1 15 Priming Sprin ...

  • Chicago Electric 99702 - page 18

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 18 PUMP DIAGRAM ...

  • Chicago Electric 99702 - page 19

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 19 PUMP DIAGRAM, CONTINUED ...

  • Chicago Electric 99702 - page 20

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 20 SUCTION TUBE ASSEMBL Y P ARTS LIST & DIAGRAM Part Description Qty 1B Hose Nut 1 2B Circlip 1 3B Connection 1 4B T ube 1 5B  1 6B Filter 1 7B Clamp 2 8B Return T ube 1 Note:  ? ...

  • Chicago Electric 99702 - page 21

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 21 GUN P ARTS LIST & DIAGRAM Part Description Qty 1C Housing 2 2C Elbow 1 3C Pin 1 4C Seal 1 5C W asher 1 6C W asher 1 7C Ball 1 8C Spring 1 9C Pipe 1 10C Filter Housing 1 1 1C Ring 2 12C Bush 1 13C Spring 1 14C T ip 1 15C Cap 1 16C T rigger 1 GUN P ARTS LIST & DIAGRAM Part ...

  • Chicago Electric 99702 - page 22

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 22 Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants ...

Manufacturer Chicago Electric Category Paint Sprayer

Documents that we receive from a manufacturer of a Chicago Electric 99702 can be divided into several groups. They are, among others:
- Chicago Electric technical drawings
- 99702 manuals
- Chicago Electric product data sheets
- information booklets
- or energy labels Chicago Electric 99702
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chicago Electric 99702.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chicago Electric 99702, service manual, brief instructions and user manuals Chicago Electric 99702. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chicago Electric 99702.

A complete manual for the device Chicago Electric 99702, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chicago Electric 99702 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chicago Electric 99702.

A complete Chicago Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chicago Electric 99702 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chicago Electric 99702, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chicago Electric 99702, that we can find in the current document
3. Tips how to use the basic functions of the device Chicago Electric 99702 - which should help us in our first steps of using Chicago Electric 99702
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chicago Electric 99702
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chicago Electric 99702 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chicago Electric 99702?

Use the form below

If you did not solve your problem by using a manual Chicago Electric 99702, ask a question using the form below. If a user had a similar problem with Chicago Electric 99702 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)