    © 2001 CUNO Incorporated 98-91220 0601 CUNO Incorporated 400 Research Parkway Meriden, CT 06450, U.S.A. Toll Free: 1-800-733-1199 Worldwide: 203-237-5541 Fax: 203-238-8701 www.waterfactorysystems.com • www.cuno.com ...

  • Cuno SQC Pro - page 2

    INTRODUCTION This manual explains the installation, operation and maintenance of the Water Factory Systems ® SQC Series Reverse Osmosis (RO) Drinking Water Appliances. Please read each section of this manual care - fully. The specific model chosen should be appropriate for the local water conditions and the customer's needs. Check the Perform ...

  • Cuno SQC Pro - page 3

    A. DETERMINE THE APPLIANCE LOCATION The appliance can be located under a sink or in a basement depending on space availability and the customer's preference. If a basement installation is selected, additional tubing, hardware and fittings may be needed and a hole will have to be made from inside the cabinet, through the floor, to the basement. ...

  • Cuno SQC Pro - page 4

    C. PREPARE THE APPLIANCE FOR INSTALLATION Open the shipping carton and remove the components. Check to see that all of the installation parts are present. They should include the purification assembly, storage tank, faucet, installation hardware, RO membrane cartridge and tubing. Check to see that the air supply in the empty tank is approxi - matel ...

  • Cuno SQC Pro - page 5

    E. MOUNT THE FAUCET Undercounter installations generally require that the faucet's built-in air gap be used. In basement installations, the built-in air gap does not have to be used if one is provided elsewhere on the drain line. For Basement Installations Without An Air Gap Module See Installation Instructions O. IMPORTANT: The Uniform Plumbi ...

  • Cuno SQC Pro - page 6

    F . INSTALL THE FEED WATER TAPPING VALVE AND TUBING The feed water tapping valve which is supplied, is designed to be used on 3/8" to 1/2" OD soft copper tubing (plain or chromed) and rigid metal pipe. Do not use it on flexi - ble ribbed tubing, because it has too thin a wall thickness and it requires special hardware. Soft Copper Tubing ...

  • Cuno SQC Pro - page 7

    5) Turn the feedwater tapping valve handle clockwise to close the valve. With a wrench, tighten the nut/seal around the valve handle stem. 6) Remove the cover from the appliance and disconnect the orange 1/4" tubing from the feedwater fitting. (See Fig. 6) 7) Connect one end of the orange tubing to the feedwater tapping valve using the brass c ...

  • Cuno SQC Pro - page 8

    I. INSTALL THE PURIFICATION ASSEMBLY AND STORAGE TANK For Basement Installation See Installation Instructions O. Undercounter Installation: The purification assembly is usually mounted to the right or the left side wall inside of the sink cabinet, taking into consider - ation the space available and the tank location. Generally, the storage tank is ...

  • Cuno SQC Pro - page 9

    L. START UP THE APPLIANCE 1) Double check to see that all of the connections are secure. 2) Open the feedwater tapping valve and check the appliance for leaks. If any leaks are detected, close the valve and correct the problem before proceeding. NOTE: If a leak occurs at a "Push In" plastic fitting, then refer to Fig. 6. 3) Open the stora ...

  • Cuno SQC Pro - page 10

    O. APPENDIX FOR BASEMENT INSTALLATIONS The following variations are generally required for basement installations: INSTALL THE DRAIN CONNECTION For basement installations, the drain saddle is generally not used. Instead, the RO reject line (SFC tubing) is routed so that it drains into a laundry sink, floor drain, or standpipe through an approved ai ...

  • Cuno SQC Pro - page 11

    Teflon is a registered trademark of E.I. DuPont 11 P. INSTALLATION TROUBLESHOOTING Problem: Leak at the feedwater tapping valve. Cause: Tapping valve is not clamped tightly enough. Solution: Tighten the tapping valve clamp screws evenly and firmly keeping both halves of the bracket parallel. Be sure not to deform tubing. Problem: Leak at the drain ...

  • Cuno SQC Pro - page 12

    A. IMPORTANT WATER QUALITY ASSURANCE REQUIREMENTS Reverse Osmosis drinking water appliances contain treat - ment components that are critical for the effective reduction of Total Dissolved Solids (TDS) as well as inorganic chemical contaminants. Water Factory Systems ® strongly recommends that the user test the water periodically (every six months ...

  • Cuno SQC Pro - page 13

    C. REPLACING THE RO MEMBRANE CARTRIDGE The life of the RO membrane cartridge depends on the local water conditions and proper maintenance, e.g., regular fil - ter changes. Under typical conditions, the RO membrane life ranges from 18-36 months. Unlike the filter cartridges, the RO membrane cartridge life is not determined by the amount of water use ...

  • Cuno SQC Pro - page 14

    4) Fill the sanitizing device with the following recommended dosage of common household bleach: • A standard 2.5 gallon tank - 1/2 teaspoon (3 ml) • Alternate size tanks - 1/2 teaspoon (3 ml) per 2.5 gallons of tank capacity 5) Open the feedwater tapping valve to force water and sanitizer into the storage tank. Allow about three (3) minutes to ...

  • Cuno SQC Pro - page 15

    Appendix 1. Electrical Diagram 15 ...

Manufacturer Cuno Category Water System

Documents that we receive from a manufacturer of a Cuno SQC Pro can be divided into several groups. They are, among others:
- Cuno technical drawings
- SQC Pro manuals
- Cuno product data sheets
- information booklets
- or energy labels Cuno SQC Pro
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cuno SQC Pro.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cuno SQC Pro, service manual, brief instructions and user manuals Cuno SQC Pro. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cuno SQC Pro.

Similar manuals

A complete manual for the device Cuno SQC Pro, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cuno SQC Pro by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cuno SQC Pro.

A complete Cuno manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cuno SQC Pro - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cuno SQC Pro, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cuno SQC Pro, that we can find in the current document
3. Tips how to use the basic functions of the device Cuno SQC Pro - which should help us in our first steps of using Cuno SQC Pro
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cuno SQC Pro
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cuno SQC Pro in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cuno SQC Pro?

Use the form below

If you did not solve your problem by using a manual Cuno SQC Pro, ask a question using the form below. If a user had a similar problem with Cuno SQC Pro it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)