    BOILER MA TE TM TOP-DOWN INDIRECT -FIRED W A TER HEA TERS WITH TOP-MOUNTED COIL The heat transfer medium should be water . If any product other than water is used, it must be a non-toxic fluid suitable for human ingestion as determined by the FDA Y our AMTROL BOILER MA TE™ has been carefully assembled and factory tested. T o enjoy the full servic ...

  • Amtrol TD-7ZDW - page 2

    -2- 1. GENERAL SAFETY INFORMA TION ...................................................................................... 3 2. PRE-INST ALLA TION CHECKLIST ........................................................................................ 4 Important Steps and Decisions Required Befor e Installation 3. REQUIRED COMPONENTS AND ACCESSORIES CHEC ...

  • Amtrol TD-7ZDW - page 3

    -3- IMPOR T ANT GENERAL SAFETY INFORMA TION - ADDITIONAL SPECIFIC SAFETY ALER TS APPEAR IN THE FOLLOWING INSTRUCTIONS EXPLOSION HAZARD: DO NOT INST ALL TO A HIGH PRESSURE STEAM BOILER (greater than 15 psig). AN EXPLOSION COULD OCCUR. EXPLOSION HAZARD. THE PRESSURE OF THE HEA T TRANSFER MEDIUM MUST BE LIMITED TO A MAXIMUM OF 30 PSIG BY AN APPROVED S ...

  • Amtrol TD-7ZDW - page 4

    -4- j THIS PRODUCT MUST BE INST ALLED AND MAINT AINED BY A LICENSED PROFESSIONAL. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND ST A TE CODES OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NA TIONAL PLUMBING CODE AND THE NA TIONAL ELECTRIC CODE. j DRIP P AN AND DRAIN: T o avoid leaking and/or property ...

  • Amtrol TD-7ZDW - page 5

    -5- TD-7Z, TD-41Z, TD-7ZDW , TD-41ZDW COMPONENTS CHECKLIST The following is a checklist of components requir ed for proper installation of these BOILER MA TE™ models, both Priority and Non-Priority: A. Separate circulator • 1 each - circulator (4-8 gpm) • 1 each - positive shut-of f weighted check valve B. Use of heating system zone cir culat ...

  • Amtrol TD-7ZDW - page 6

    -6- A. General Installation Requir ements 1. Do not "short circuit" the boiler Do not connect boiler supply and return lines to the same section or in the same flow circuit in a boiler , because the boiler water returning from the BOILER MA TE™ will "short circuit" and exit the boiler too cold for pr oper heat transfer . 2. Av ...

  • Amtrol TD-7ZDW - page 7

    -7- B. PIPING PIPING SHOULD BE ACCOMPLISHED WITH UNIONS. Step 1 - Locate the BOILER MA TE™ near boiler . Step 2 - Connect the cold water piping. a. Shut off the cold water supply at the main shut-of f valve. b. Drain existing domestic water system. Open 1 or more system faucets to pr event vacuum. c. When the system is drained, for boilers that h ...

  • Amtrol TD-7ZDW - page 8

    -8- Step 5 - Connect boiler supply pipe. Figure 1. a. Shut off the cold water supply valve to the boiler , and drain it using a hose attached to the drain valve at the boiler . b. When the boiler system piping is drained, cut the piping to accommodate the supply line tee. Install the tee between the boiler supply outlet and any system zone valve or ...

  • Amtrol TD-7ZDW - page 9

    -9- the service switch). c. Switch of f the branch cir cuit breaker . Step 2 - Remove electrical box cover . Step 3 - Remove existing wir e fr om boiler aquastat terminal C1 and connect to terminal #2 on DPDT relay . Step 4 - Install wire fr om DPDT relay terminal #1 to boiler aquastat terminal C1. Step 5 - Connect terminals of 4 and 6 of DPDT rela ...

  • Amtrol TD-7ZDW - page 10

    -10- ...

  • Amtrol TD-7ZDW - page 11

    - 11 - The BOILER MA TE™ is intended to pr ovide a tank service life of many years. Components, however , may be subject to failur es that requir e service. Failure to use the corr ect procedur es or parts in these circumstances may make the unit unsafe. • DO NOT OPEN DOWN-STREAM FIXTURE IF YOU HA VE LOOSENED THE TOP CONNECTIONS. • DO NOT OVE ...

  • Amtrol TD-7ZDW - page 12

    -12- RESIDENTIAL BOILER MA TE™ CLASSIC (TD-7Z and TD-41Z) ELECTROCUTION HAZARD. THE BOILER MA TE™ MUST BE ELECTRICALL Y GROUNDED. NOTES: 1. THE BOILER MA TE™ MUST BE ELECTRI- CALL Y GROUNDED AND INST ALLED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NA TIONAL ELECTRIC CODE. 2. HEA T EXCHANGER P ACKAGE INCLUDE IT ...

  • Amtrol TD-7ZDW - page 13

    - 13 - PROBLEM CAUSE SOLUTION 1. No hot water at faucet. 1. Boiler does not operate. 1. a. Press reset button on boiler . b. Check main cut-off switch. c. Check fuse. 2. Circulator does not operate. 2. a. Check power supply . b. Check shaft coupling. c. Check impeller for locking. 3. Improper BOILER MA TE™ 3. Set BOILER MA TE™ temperature to se ...

  • Amtrol TD-7ZDW - page 14

    -14- DA TE SERVICE PERFORMED COMMENTS CONTRACTOR 9. SERVICE RECORD ...

  • Amtrol TD-7ZDW - page 15

    AMTROL ® BOILERMA TE ™ CLASSIC AND TOP-DOWN™ LIMITED PRODUCT WARRANTY This W arranty cannot be transferred - it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this Product you agree to all of the warranty terms and limitations of liability described below . I MPOR T ANT W ARNING: READ CAREFULL ...

  • Amtrol TD-7ZDW - page 16

    West W arwick, Rhode Island 02893 Part #: 9040-628 REV B (7/04) -16- ...

Manufacturer Amtrol Category Electric Heater

Documents that we receive from a manufacturer of a Amtrol TD-7ZDW can be divided into several groups. They are, among others:
- Amtrol technical drawings
- TD-7ZDW manuals
- Amtrol product data sheets
- information booklets
- or energy labels Amtrol TD-7ZDW
All of them are important, but the most important information from the point of view of use of the device are in the user manual Amtrol TD-7ZDW.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Amtrol TD-7ZDW, service manual, brief instructions and user manuals Amtrol TD-7ZDW. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Amtrol TD-7ZDW.

Similar manuals

A complete manual for the device Amtrol TD-7ZDW, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Amtrol TD-7ZDW by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Amtrol TD-7ZDW.

A complete Amtrol manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Amtrol TD-7ZDW - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Amtrol TD-7ZDW, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Amtrol TD-7ZDW, that we can find in the current document
3. Tips how to use the basic functions of the device Amtrol TD-7ZDW - which should help us in our first steps of using Amtrol TD-7ZDW
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Amtrol TD-7ZDW
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Amtrol TD-7ZDW in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Amtrol TD-7ZDW?

Use the form below

If you did not solve your problem by using a manual Amtrol TD-7ZDW, ask a question using the form below. If a user had a similar problem with Amtrol TD-7ZDW it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)