Manual Scytek electronic 2200

40 pages 0.5 mb
Download

Go to site of 40

Summary
  • Scytek electronic 2200 - page 1

    PRECISION 5500 VEHICLE SECURITY SYSTEM WITH REMOTE START PRECISION 2200 REMOTE START ONLY PRODUCT MANUAL ...

  • Scytek electronic 2200 - page 2

    L i m i t e d L i f e t i m e W a r r a n t y This system is warranted to the original purchaser , to be free from defects in material and workmanship. The manufacturer will rep air or replace at its option, and free of charge for the first twelve (12) months, any part that proves defective in material or workmanship under normal installation, use, ...

  • Scytek electronic 2200 - page 3

    1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T r ansmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P age 2 Remote T r ansmitter Description . . . . . . . . . . . . . . . . . . . . ...

  • Scytek electronic 2200 - page 4

    ...

  • Scytek electronic 2200 - page 5

    The ScyT ek Precision 5500 Series is a Combination Vehicle Security and Remote Starting System that will have f eatures and functions that will be described in the following sections with an ASTERICK * The Precision 2200 Series is a Remote Start System only . Both series feature a built -in "ScyNet Network P ort" that allows direct connec ...

  • Scytek electronic 2200 - page 6

    Standard Remote Transmitter Description The Precision 5500, 2200 Series is supplied with one 5-button R emote T ransmitter that is used to control the system’ s operations. Note : Using the optional PC or P ocket PC interface with the network softw are, it is possible to reconfigure the functionality of the tr ansmitter buttons. The standard (def ...

  • Scytek electronic 2200 - page 7

    Adding/Replacing Standard Remote Transmitters T o replace lost or stolen tr ansmitters or to add additional transmit ters into the system, have all desired transmit ters ready and follow the steps below . Note : Up to 4 one-wa y transmitters can be progr ammed to operate the system. An y previously stored transmit ter will be erased if it is not pr ...

  • Scytek electronic 2200 - page 8

    2-way LCD Remote Transmitter Description The Precision 5500 and 2200 are supplied with a 2-wa y LCD remote transmitter , offering increased r ange and confirmation of any activ ated features. Page 1 Button 1 Arms* and Locks the system and when held for 5 seconds, activ ates the system’ s Panic f eature. Button 1 also locks the doors when the syst ...

  • Scytek electronic 2200 - page 9

    3. Press and release Button 1 on the first tr ansmitter , then on the second transmitter . · The siren*/horn will chirp/honk once for every tr ansmitter learned. 4. T urn off the ignition k ey . 5. The siren*/horn will chirp/honk 3 times to indicate the system has exited programming mode. LCD Transmitter Battery Replacement Y our Precision R emote ...

  • Scytek electronic 2200 - page 10

    T o set the daily start feature: 1. Press and hold Buttons 2 and 3 until the remote beeps four times. · The fan and clock will be shown indicating daily start mode is entered. 2. Press Button 2 until the desired hour is displayed. 3. Press Button 3 until the desired minute is displayed. The but ton may be held down to scroll faster . 4. When the d ...

  • Scytek electronic 2200 - page 11

    Precision - Page 7 CHP Set the siren*/horn confirmation chirps*/honks ON or OFF : 1. Press and hold Button 5 until the display shows CHP . ·The tr ansmitter will beep three times. 2. Release But ton 5. · The transmit ter will beep once. · The LCD panel will show a siren if the chirps*/honks are enabled or "off " if the chirps*/honks ar ...

  • Scytek electronic 2200 - page 12

    Page 8 - Precision ...

  • Scytek electronic 2200 - page 13

    Precision - Page 9 Remote Arming*/Locking The system monitors 5 independent areas ( zones ) while armed: doors, hood/ trunk, shock sensor , optional sensor input, and the network port for future expansion.* T o Arm* and Lock the S ystem: 1. T urn off the ignition. 2. Press Button 1. · The siren*/horn will chirp/honk once. · The doors will lock.( ...

  • Scytek electronic 2200 - page 14

    Page 10 - Precision * Tamper Alert If the system was triggered while awa y , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition. The LED indication will repeat 5 times. LED Flashes: 1 flash = optional sensor 2 flashes = shock sensor 3 flashes = network based sensor 4 flashes = door 6 flashes = ...

  • Scytek electronic 2200 - page 15

    Precision - Page 11 Panic Mode In the event of an emergency , the transmit ter’s remote P anic feature can be used to instantly trigger the alarm*/panic feature. T o activ ate the Panic Mode: 1. Press and hold Button 1 for 5 seconds. · The alarm will sound. · The parking lights will flash. · The doors will unlock** allowing access to the vehic ...

  • Scytek electronic 2200 - page 16

    Page 12 - Precision T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide one long chirp, indicating that y ou have entered Progr amming. 3. Press the valet switch 4 times. · The siren will chirp each time the valet switch is pressed. 4. Within 5 seconds, press But ...

  • Scytek electronic 2200 - page 17

    Precision - Page 13 Remote Starting T o R emote Start the System: 1. Be sure the system is not in V alet Mode. 2. Press and hold Button 4 for three seconds. · The parking lights will flash 4 times and turn on. · The siren*/horn will chirp/honk 4 times.( if enabled, see page 23 branch 9 f or 5500 Series) ( if enabled, see page 25 branch 22 f or 22 ...

  • Scytek electronic 2200 - page 18

    Page 14 - Precision Automatic Start Mode Automatic Start feature has three modes that will start the vehicle every one or two hours within a 24 hour period. 1. Timer Only Mode (factory def ault) The Automatic Start feature starts the vehicle automatically ev ery one or two hours and runs for the preset Run Time. (15 or 25 min) Auto Start On Timer M ...

  • Scytek electronic 2200 - page 19

    Precision - Page 15 Model: Precision 5500-M Precision 2200-M 1- T ach wire must be connected , The system must learn RPM. 2- Hand brak e must be connected. 3- Door trigger must be connected 4- Clutch override installed NOTE: MUST USE RELAY, SEE PAGE 28. Remote Starting With engine running and Hand-brak e engaged put the vehicle transmission in neut ...

  • Scytek electronic 2200 - page 20

    Page 16 - Precision E x t e n d e d F e a t u r e s Ignition Door Locking F or added safety , the Ignition Door Locking f eature allows vehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on. If a door is open when the ignition is turned on, the Ignition Door Locking feature is disabled to prot ...

  • Scytek electronic 2200 - page 21

    Precision - Page 17 1. Thoroughly read and become familiar with the installation instructions bef ore beginning the installation. 2. R eview system contents: Main Unit 1 T wo-wa y 5 Button LCD R emote T ransmit ter and 1 One-W ay 5 Button R emote T ransmit ter Siren* Shock Sensor* Harnesses • 6-Pin starter harness • 20-Pin main harness • 4-Pi ...

  • Scytek electronic 2200 - page 22

    Page 18 -Precision Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. Choose a mounting location that will not be easily accessible to a thief , and will not interfere with the oper ation of any vehicle components such as f oot pedals, steering column ...

  • Scytek electronic 2200 - page 23

    Precision - Page 19 S y s t e m W i r i n g 6-Pin Starter Harness Pin 1 RED WIRE A : Main P ower Input A (+). Connect to the battery or constant power wire at the ignition switch with a minimum 25 Amp supply . R emo v e the f use until the installation is complete and all wiring is check ed. Pin 2 RED WIRE B : Main Power Input B (+). Connect to the ...

  • Scytek electronic 2200 - page 24

    Page 20 - Precision Pin 11 VIOLET WIRE : Positive Door Input (+). Connect to the door switch circuit wire that shows +12V when the door is open. This type of door circuit is usually found on F ord vehicles. Pin 12 GREEN WIRE : Negative Door Input (-). Connect to the door switch circuit wire that shows ground when the door is open. Pin 13 WHITE/BLAC ...

  • Scytek electronic 2200 - page 25

    Precision - Page 21 2-Pin White Connector: Located on the side of the main module. · Green WIRE - P arking Brake Input (-) F or Manual T r ansmission and/or vehicles equipped with a turbo charged engine. Must be connected if using the T urbo Timer feature and/or Manual T ransmission remote start feature. · Blue WIRE - T urbo Timer cancel input fo ...

  • Scytek electronic 2200 - page 26

    Page 22 - Precision Entering System Programming This system is compatible with both the LCD two wa y transmitter or the standard tr ansmitter , all system programming can be perf ormed using either one. T o enter S ystem Programming: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren*/horn will provide three chi ...

  • Scytek electronic 2200 - page 27

    Precision - Page 23 5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is turned off . The Ignition Door Locking feature may be progr ammed to unlock all doors or the driver’ s door only . If driver’s door only is selected, the optional P assenger Unlock wire must be connected. ( See ...

  • Scytek electronic 2200 - page 28

    Page 24 -Precision 10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a residual dome light circuit that remains on for a period of time after closing the door . 11. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output will activate when the system is armed. This feature can be used to roll- ...

  • Scytek electronic 2200 - page 29

    Precision - Page 25 plugs are warm before cr anking the starter . If the glow plug wire is not connected, the built-in timer waits 15 seconds before automatically cr anking the starter . 22. Ignition 2 Relay Program. Selects one of three operating modes for the Ignition 2 rela y output: Ignition 2, Accessory 2, or Starter 2. 23. Horn Output. When s ...

  • Scytek electronic 2200 - page 30

    Page 26 - Precision Programmable System Options The following is a description of the progr amming options of the system. Some of the program br anches control more than one option, and may require accessing a particular br anch number twice in order to program all desired f eatures. 1. Ignition Door Locking. Selects whether or not the system will ...

  • Scytek electronic 2200 - page 31

    Precision - Page 27 15. Remote Start Program . This dual progr am branch sets the engine mode for Gas or Diesel, and learns the vehicle’ s RPM threshold. F or installation into a diesel equipped vehicle, first set the engine type to diesel before learning RPM. RPM Learn. After engine type is set, start the engine, re-enter Br anch 15, LED will st ...

  • Scytek electronic 2200 - page 32

    Page 28 - Precision R e l a y D i a g r a m s P ositive Dome Light Activ ation Negative Dome Light Activ ation P ositive Horn Honk Negative Horn Honk Starter Defeat/Anti-Grind Negative Glow Plug ...

  • Scytek electronic 2200 - page 33

    Precision - Page 29 Negative T rigger R everse P olarity V acuum Adding Actuators F ollow the diagrams below for connecting basic door lock systems. F or T wo Stage door lock systems (separately unlocks driv er and passenger doors) see following pages. D o o r L o c k D i a g r a m s P ositive T rigger UL L blue green ...

  • Scytek electronic 2200 - page 34

    Page 30 - Precision T w o S t a g e D o o r L o c k D i a g r a m s T wo Stage Negative T rigger T wo Stage P ositive T rigger The Precision 5500 and 2200 Series is equipped with a dedicated P assenger Unlock output allowing T wo Stage Door Lock operation. When connected as shown below , disarming the system will unlock only the driver’ s door . ...

  • Scytek electronic 2200 - page 35

    Precision - Page 31 T w o S t a g e D o o r L o c k Diagrams c o n t ’ d T wo Stage R everse P olarity T wo Stage Adding Actuators ...

  • Scytek electronic 2200 - page 36

    FCC ID: OARRXAM2000 This device complies with P art 15 of FCC Rules. Operation is subject to the f ollowing two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interf erence that may cause undesired operation T e c h n i c a l I n f o r m a t i o n Page 32 - Precision Bu ...

  • Scytek electronic 2200 - page 37

    S t a r t e r D i a g n o s t i c s Starter doesn’t start and parking lights flash: 3 Times - Engine RPM not detected (check tach wire and/or perform tach learn procedure) Hood Trigger is active (hood is open, wire is shorted to ground or pin switch is defective) 4 Times - Brake Trigger is active ( Brake switch input is shorted to ground or incor ...

  • Scytek electronic 2200 - page 38

    Page 34 - Precision N o t e s : ...

  • Scytek electronic 2200 - page 39

    Precision - Page 35 N o t e s : ...

  • Scytek electronic 2200 - page 40

    ScyTek Electronics 11627 Cantara Street North Hollywood, CA 91605 www .scytek.net © ScyT ek Electronics 2006 Precision 8-10-06 W i r i n g D i a g r a m ScyNet Blue S tart (-)* Turbo T imer Cancel Green Emergency brake(-) Antenna *Shock Sensor ( Auxiliar y Star t input) LED V alet Switch Green Lock output (-) 500mA Blue Unlock output (-) 500mA Gre ...

Manufacturer Scytek electronic Category Automobile Alarm

Documents that we receive from a manufacturer of a Scytek electronic 2200 can be divided into several groups. They are, among others:
- Scytek electronic technical drawings
- 2200 manuals
- Scytek electronic product data sheets
- information booklets
- or energy labels Scytek electronic 2200
All of them are important, but the most important information from the point of view of use of the device are in the user manual Scytek electronic 2200.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Scytek electronic 2200, service manual, brief instructions and user manuals Scytek electronic 2200. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Scytek electronic 2200.

A complete manual for the device Scytek electronic 2200, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Scytek electronic 2200 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Scytek electronic 2200.

A complete Scytek electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Scytek electronic 2200 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Scytek electronic 2200, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Scytek electronic 2200, that we can find in the current document
3. Tips how to use the basic functions of the device Scytek electronic 2200 - which should help us in our first steps of using Scytek electronic 2200
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Scytek electronic 2200
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Scytek electronic 2200 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Scytek electronic 2200?

Use the form below

If you did not solve your problem by using a manual Scytek electronic 2200, ask a question using the form below. If a user had a similar problem with Scytek electronic 2200 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (1)

Nacho

No puedo quitar el retardo"el reloj"como puedo desactivarlo