Manual ADTRAN T200 FNID

16 pages 0.12 mb
Download

Go to site of 16

Summary
  • ADTRAN T200 FNID - page 1

    1 Section 61245201L1-5, Issue 3 61245201L1-5C FNID and T200 FNID Fractional T1 Network Interface Device Installation and Maintenance CONTENTS 1. GENERAL ............................................................................ 1 2. INSTALLATION .................................................................. 2 3. CONNECTIONS .................. ...

  • ADTRAN T200 FNID - page 2

    2 Section 61245201L1-5, Issue 3 61245201L1-5C With the exception of the physical dimensions of the units, the FNID and T200 FNID units are functionally identical. The FNID terminates local loop DSL signals originating from the Central Office (CO) unit and transforms the DSL signal into fractional T1 signals to be delivered to the customer. The DSL ...

  • ADTRAN T200 FNID - page 3

    3 Section 61245201L1-5, Issue 3 61245201L1-5C 3. CONNECTIONS All connections of the FNID are made through card edge connectors. Table B gives the card edge pin assignments for the FNID circuit pack. The circuit pack operates in either the standalone chassis (P/N 1242034L2), the ADTRAN HR4 HDSL shelf (P/N 1242008L1), or the ADTRAN HR12 HDSL shelf (P ...

  • ADTRAN T200 FNID - page 4

    4 Section 61245201L1-5, Issue 3 61245201L1-5C 5. CONTROL PORT OPERATION The FNID provides a faceplate-mounted DB9 connector that supplies an RS-232 interface for connection to a controlling terminal. The pinout of the DB9 is illustrated in Figure 4. The terminal interface operates at data rates from 2.4 kbps to 19.2 kbps. The asynchronous data form ...

  • ADTRAN T200 FNID - page 5

    5 Section 61245201L1-5, Issue 3 61245201L1-5C From the Main menu the following screens can be accessed. 1. Current System Status 2. Performance History 3. ADTRAN Information 4. Loopback Options 5. Self Test 6. Provisioning 7. Troubleshooting The Current System Status screen, illustrated in Figure 7, provides quick access to status information for b ...

  • ADTRAN T200 FNID - page 6

    6 Section 61245201L1-5, Issue 3 61245201L1-5C A measure of signal quality for each HDSL loop is displayed in graphic form on the bottom right and left of the screen. The measure is from 0 (poor signal quality) to 9 (excellent signal quality). Guidelines for interpreting the indicators are: 0 Noise margin is ≤ 0 dB ( ≈ 10 -7 BER) 1-8 Margin meas ...

  • ADTRAN T200 FNID - page 7

    7 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 5. Introductory Menu Screen ADTRAN 901 Explorer Boulevard Huntsville, Alabama 35806-2807 For Information or Technical Support, Normal Support Hours ( 7am - 7pm CST ) or Emergency Support Hours ( 7x24 ) Voice Toll Free: 800.726.8663 Fax: 256.963.6217 Voice: 256.963.8100 Internet: www.adtran.com ? ...

  • ADTRAN T200 FNID - page 8

    8 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 7. Current System Status Screen FT1-DP CURRENT SYSTEM STATUS FNID NETWORK (DSL) ELAPSED TIME 00:08:18 CUSTOMER (DSL) ---------------------- ----------------- 00 dB <- LOSS -> 00 dB NO <- SYNC -> NO 000/00000 <- ES 15M/24H -> 000/00000 000/00000 <- SES 15M/24H -> 000/00000 ...

  • ADTRAN T200 FNID - page 9

    9 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 9. Loopback Options Screen LOOPBACK OPTIONS FT1-DP FNID _____ _____ | | | | | | | | —-->| | | |<—- | | | | NET | |<===========================>| | CUST | | | | <—--| | | |—> | | | | | | | | |_____| |_____| 1) LOOPBACK TO NETWORK AT FT1-DP =INACTIVE 2) LOOPBACK TO CUSTOME ...

  • ADTRAN T200 FNID - page 10

    10 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 11. Provisioning Options Screen PROVISIONING ___________________________________________________ ______________________ | | | | PROVISIONS CURRENT SETTINGS | HARDWARE SETTINGS | | ------------------------------------------ | ----------------- | | 1. DS1 (FNID) LINE CODE = B8ZS | B8ZS | | 2. DS1 ...

  • ADTRAN T200 FNID - page 11

    11 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 13. DSL Deployment Guidelines 6. DSL DEPLOYMENT GUIDELINES The ADTRAN FT1 DSL system is designed to provide Fractional DS1-based services over loops designed to comply with Carrier Service Area (CSA) guidelines. CSA deployment guidelines are given below. 1 . All loops are non-loaded only. 2. For ...

  • ADTRAN T200 FNID - page 12

    12 Section 61245201L1-5, Issue 3 61245201L1-5C 7. TROUBLESHOOTING PROCEDURES Table E is a troubleshooting guide for the FNID. 8. MAINTENANCE The ADTRAN FNID requires no routine maintenance. In case of equipment malfunction, use the faceplate Bantam jack connectors to help locate the source of the problem. ADTRAN does not recommend that repairs be p ...

  • ADTRAN T200 FNID - page 13

    13 Section 61245201L1-5, Issue 3 61245201L1-5C Loop Interface: Modulation Type ................................................. 2B1Q Mode .................................................................... Full Duplex, Echo Cancelling Number of Pairs .................................................. One Bit Rate ................................. ...

  • ADTRAN T200 FNID - page 14

    A-1 Section 61245201L1-5, Issue 3 61245201L1-5C Appendix A FT1 Loopbacks 1. GENERAL This Appendix is an overall reference to the loopback capabilities of the ADTRAN Fractional T1 system. Included in this Appendix is a description of the FT1 loopbacks and the methods for activating the FT1 loopbacks. 2. FT1 LOOPBACKS Figure A-1 shows the application ...

  • ADTRAN T200 FNID - page 15

    A-2 Section 61245201L1-5, Issue 3 61245201L1-5C There is one loopback available to the FT1 Repeaters. The FT1 Repeater Network loopback is a digital loopback toward the CO as shown in Figure A-4. The loopbacks are initiated by the DDS latching loopback codes for NEI Position 1 (N1000001) for FT1 #1 or NEI Position 2 (N100001) for FT1 Repeater # 2. ...

  • ADTRAN T200 FNID - page 16

    A-3 Section 61245201L1-5, Issue 3 61245201L1-5C 3. LOOPBACK ACTIVATION/DEACTIVATION This section describes loopback activation and deactivation methods for the ADTRAN Fractional T1 system. Loopback activation and deactivation is controlled with the push-button located on the front panel, through craft interface, or latching loopback codes. Both the ...

Manufacturer ADTRAN Category Network Card

Documents that we receive from a manufacturer of a ADTRAN T200 FNID can be divided into several groups. They are, among others:
- ADTRAN technical drawings
- T200 FNID manuals
- ADTRAN product data sheets
- information booklets
- or energy labels ADTRAN T200 FNID
All of them are important, but the most important information from the point of view of use of the device are in the user manual ADTRAN T200 FNID.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ADTRAN T200 FNID, service manual, brief instructions and user manuals ADTRAN T200 FNID. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ADTRAN T200 FNID.

A complete manual for the device ADTRAN T200 FNID, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ADTRAN T200 FNID by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ADTRAN T200 FNID.

A complete ADTRAN manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ADTRAN T200 FNID - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ADTRAN T200 FNID, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ADTRAN T200 FNID, that we can find in the current document
3. Tips how to use the basic functions of the device ADTRAN T200 FNID - which should help us in our first steps of using ADTRAN T200 FNID
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ADTRAN T200 FNID
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ADTRAN T200 FNID in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ADTRAN T200 FNID?

Use the form below

If you did not solve your problem by using a manual ADTRAN T200 FNID, ask a question using the form below. If a user had a similar problem with ADTRAN T200 FNID it is likely that he will want to share the way to solve it.

Copy the text from the picture