Manual Highpoint RocketRAID 2320

77 pages Not applicable
Download

Go to site of 77

Summary
  • Highpoint RocketRAID 2320 - page 1

    RocketRAID 2320 S A T AII Host Adapter User’s Guide Revision: 1.0 Date: August 2005 HighPoint T echnologies, Inc. ...

  • Highpoint RocketRAID 2320 - page 2

    Copyright Copyright © 2005 HighPoint T echnologies, Inc. This document contains materials protected by International Copyright Laws. All rights reserved. No part of this manual may be reproduced, transmitted or transcribed in any form and for any purpose without the express written permission of HighPoint T echnologies, Inc. T rademarks Companies ...

  • Highpoint RocketRAID 2320 - page 3

    T able of Contents Chapter 1 Introduction About this Guide ................................................................................................... Introducing the RocketRAID 2320 Host Adapter .......................................... Product Features ...................................................................................... ...

  • Highpoint RocketRAID 2320 - page 4

    WINDOWS DRIVER INST ALLA TION ........................................................... 1 - Installing the RAID Management Console/ Interface Overview .......... 2 - Software Interface - Overview of commands/functions ........................... 3 - Creating an Array ................................................................................ ...

  • Highpoint RocketRAID 2320 - page 5

    Chapter 1 Introduction Contents of this Chapter: About this Guide Introducing the RocketRAID 2320 Host Adapter Product Features Understanding RAID Concepts and T erminology ...

  • Highpoint RocketRAID 2320 - page 6

    About this Guide The RocketRAID 2320 SA T AII Host Adapter’s User’s Guide provides information about the functions and capabilities of the host adapter, and instructions for installing, configuring and maintaining RAID arrays hosted by the adapter. Introducing the RocketRAID 2320 Host Adapter The HighPoint RocketRAID 2320 is an 8-channel PCI-Ex ...

  • Highpoint RocketRAID 2320 - page 7

    Understanding RAID Concepts and T erminology The following concepts and terminology is commonly used when describing the functions of the RocketRAID 2320 Host Adapter . Disk initialization Initializing a disk writes necessary RAID configuration information to that disk. Disks must be initialized before configuring them into RAID arrays. The initial ...

  • Highpoint RocketRAID 2320 - page 8

    Foreground initialization Foreground initialization will zero-out all data on the array. The array is not accessible by the operating system until initialization is complete. Background initialization Background initialization allows the array to be used immediately. For RAID 1 and RAID 10 arrays, initialization will results in data being duplicate ...

  • Highpoint RocketRAID 2320 - page 9

    Spare disk A spare disk is a single disk that can be used to automatically rebuild a redundant array in case of drive failure. Spare disks may also be members of a RAID array . Any available space on these disks may be used to rebuild other broken arrays. Legacy disk Disks attached to the RocketRAID 2320 that contain valid partition tables will be ...

  • Highpoint RocketRAID 2320 - page 10

    Chapter 2 RocketRAID 2320 Hardware Description/Installation Contents of this Chapter: RocketRAID 2320 Hardware 1 - RocketRAID 2320 Adapter Layout 2 - LED Connections 3 - Installing the RocketRAID 2320 Host Adapter 4 - V erifying Installation 5 - Single-RAID Cross Adapter ...

  • Highpoint RocketRAID 2320 - page 11

    RocketRAID 2320 Hardware 1 – RocketRAID 2320 Adapter Layout Port1- Port8 These represent the RocketRAID 2320’s eight SA T AII channels. The SA T A port furthest away from the surface of the adapter is always the odd numbered channel (1, 3, 5, 7), while the port closest to the adapter is the even numbered channel (2, 4, 6, 8). J2, J3, J4, J5 LED ...

  • Highpoint RocketRAID 2320 - page 12

    2 - LED Connections The RocketRAID 2320 has 4 LED jumpers – J2, J3, J4 and J5. The following diagrams describe the connector pin definitions for the Disk Activity jumpers (J2, J3), and Disk Failure connections (J4, J5). The “Ports” refer to the RocketRAID 2320’s eight SA T AII channels. RocketRAID 2320 Hardware Description/Installation 2-2 ...

  • Highpoint RocketRAID 2320 - page 13

    RocketRAID 2320 LED Guide For more information about LED support, and installation guides for various chassis configurations, consult the RocketRAID 2320 LED Guide (which will be available for download), or contact our Customer Support Department. 3 - Installing the RocketRAID 2320 Host Adapter Note: Make sure the system is powered-off before insta ...

  • Highpoint RocketRAID 2320 - page 14

    4 . After installing the adapter, attach hard disks to the RocketRAID 2320 using an SA T A data cable. SA T A cables have universal connections – either end can be attached to the adapter or hard disk. Each RocketRAID 2320 included eight SA T A cables, and supports up to eight separate hard disks drives. 5 . Many server-level chassis include hard ...

  • Highpoint RocketRAID 2320 - page 15

    Each cross-adapter cable has a 3-pin and 4-pin connector, designed for insertion into JP3 and JP4 respectively. Example installation: For a 16-hard disk, 2-card cross-adapter RAID configuration, install a second card into the next available PCI-Express slot. Insert one end of the cross-adapter cable into the appropriate jumper on the first adapter ...

  • Highpoint RocketRAID 2320 - page 16

    Chapter 3 RocketRAID 2320 BIOS Utility Contents of this Chapter: RocketRAID 2320 BIOS Utility 1 - BIOS Command Overview 2 - Creating RAID Arrays 3 - Adding/Removing Spare Disks ...

  • Highpoint RocketRAID 2320 - page 17

    RocketRAID 2320 BIOS Utility The RocketRAID 2320’s BIOS Utility can be accessed using the “Ctrl+H” command. This command should be displayed automatically when the RocketRAID 2320’s BIOS screen appears during the system’s boot up procedure. 1 - BIOS Command Overview The RocketRAID 2320 BIOS Utility provides a wide selection of RAID relate ...

  • Highpoint RocketRAID 2320 - page 18

    Add/Remove Spare - this command is used to assign hard disks to function as spare disks. The controller is capable of using spare disks to automatically rebuild broken or faulted RAID arrays. Section 3 discusses this command in detail. Settings Set Boot Mark - this function is used to designate a particular disk or RAID array to function as the Roc ...

  • Highpoint RocketRAID 2320 - page 19

    2 - Creating RAID Arrays Initializing Disks: Before creating a RAID array, the disks must be initialized. Initialization writes necessary RAID configuration information to the hard disk. Use the ← → ← → ← → ← → ← → arrow keys to select the Initialize command, and press ENTER. W arning: Initialization will destr oy all pre- exist ...

  • Highpoint RocketRAID 2320 - page 20

    6 . Next, use the ↓ ↓ ↓ ↓ ↓ arrow key to highlight the Capacity (GB) option and press ENTER. The total available capacity will be displayed. Press ENTER if you wish to use all available space. 7 . If you wish to reserve disk space for additional arrays/single disks, use the keyboard to input the amount of space (in GB) you wish to set asi ...

  • Highpoint RocketRAID 2320 - page 21

    3 - Adding/Remove Spare Disks This command is used to assign a hard disk to act as a Spare Disk. Spare Disks are used to automatically rebuild Redundant RAID arrays (RAID 1, 5, 10) in the case of disk failure. T o set a hard disk to act as a Spare Disk, use the ↑ ↓ ↑ ↓ ↑ ↓ ↑ ↓ ↑ ↓ arrow keys to select a disk, and press ENTER. T ...

  • Highpoint RocketRAID 2320 - page 22

    Chapter 4 RocketRAID 2320 Driver and Software Installation Microsoft Windows (2000, XP, 2003 Server) Contents of this Chapter: Driver and Software CD W indows Driver Installation ...

  • Highpoint RocketRAID 2320 - page 23

    Driver and Software CD The RocketRAID 2320 retail box includes a Driver and Software CD. This CD can be used to generate driver diskettes, and install the RAID Management software for a variety of operating systems. T o cr eate a driver diskette: 1 . Insert the CD into the system’s CD/DVD drive. The program should start automatically. 2 . Insert ...

  • Highpoint RocketRAID 2320 - page 24

    Click on the “Please Select the Diskette you want to create” drop-down button, and select the appropriate OS from the list. Click on the “OK” button to create the driver diskette. RocketRAID 2320 Driver and Software Installation 4-2 ...

  • Highpoint RocketRAID 2320 - page 25

    T o install the RAID softwar e: Click on “Install RAID Management Software”. Select the desired software from the drop down menu, and click on the “OK” button. RocketRAID 2320 Driver and Software Installation 4-3 ...

  • Highpoint RocketRAID 2320 - page 26

    Windows Driver Installation Before installing the RocketRAID 2320 device driver, make sure the RocketRAID 2320 host adapter and all required hard disks have been installed into the system’s chassis (refer to the Hardware Installation section, page 2-3). Installing the RocketRAID 2320 driver for an existing Windows XP/ 2003/x64 system After the op ...

  • Highpoint RocketRAID 2320 - page 27

    2 . In the popup window, select Hardware tab and then click Device Manager button. 3 . Double click the “SCSI and RAID controllers” entry. If the RocketRAID 2320 device entry is not displayed, or there are “?” or “!” marks displayed near the RocketRAID 2320 entry, the driver has not been installed properly. Delete the entries and reinst ...

  • Highpoint RocketRAID 2320 - page 28

    Logging On The RAID Management Console requires that a user (or Administrator) log on. The software is incapable of working with RAID arrays or hard disks attached to the RocketRAID 2320 until the user has logged on. Default Parameters: System Address: 127.0.0.1 Port: 7402 User Name: RAID Password: hpt Note: The password and user name fields are ca ...

  • Highpoint RocketRAID 2320 - page 29

    2 - Software Interface - Overview of commands/functions After logging on, several new options will become available. These commands are displayed towards the top of the interface window: Overview of Function-menus (tabs) File Remote Control - V iew information about remote systems System Configuration - Switch between available remote systems User ...

  • Highpoint RocketRAID 2320 - page 30

    Operation This menu will list all available commands for the selected Function menu. These commands are also represented in icon/button form (below the function-menu/ tabs selections) Help Search through help topics related to the RAID Management Console software V iew software version information 3 - Creating an Array T o cr eate an array: 1 . Hig ...

  • Highpoint RocketRAID 2320 - page 31

    3 . Select the desired RAID level from the drop-down list. 4 . Enter a name for the array using the keyboard (this is optional), and click the Next button. 5 . If you are creating a redundant array (RAID 1, 5, 10), select an initialization option. If you are creating a RAID 0 or JBOD (volume), skip to step 6: For RAID 1 and RAID 10 arrays, the defa ...

  • Highpoint RocketRAID 2320 - page 32

    Press Enter to use the default value (the maximum capacity for the array), or specify the desired value using the keyboard, and press Enter to confirm this selection. Then, click the Finish button. Note: If you have specified an initialization option, the initialization process will start automatically. A progress bar will be displayed towards the ...

  • Highpoint RocketRAID 2320 - page 33

    5 - Configuring Spare Disks Spare disks can be used to rebuild redundant RAID arrays in the case of failure. T o configure spare disks, highlight the “Management” menu, and select the “Spare Management” function. The Spare Management window will appear. T o add a spare disk, select it from the A vailable Disk list box and click the button t ...

  • Highpoint RocketRAID 2320 - page 34

    2 . Highlight the array that needs to be rebuilt. 3 . Click the Rebuild button on the toolbar or select the “Rebuild” command from the “Operation” menu. V erifying an Array For a RAID 1 or RAID 10 array, the verify process compares the data of one mirror pair with the other (single hard disk in the case of RAID 1, and a paired set of disks ...

  • Highpoint RocketRAID 2320 - page 35

    T o perform OCE/ORLM on an array: 1 . Highlight the “Management” menu, and select the “Array Management” function. 2 . Highlight the array you want to alter. 3. Click the button on the toolbar or select “OCE/ORLM” command from the “Operation” menu. 4 . The OCE/ORLM window will appear. 5 . The interface is very similar to the Array C ...

  • Highpoint RocketRAID 2320 - page 36

    8 - Misc. Array/Device Options Device Management The Device Management window provides configuration information about control- lers (the RocketRAID 2320 and other HighPoint host adapters), channels and hard disks. T o access the Device Management window , highlight the “Management” menu, and select the “Device Management” function. Changin ...

  • Highpoint RocketRAID 2320 - page 37

    SAF-TE Management This feature allows the administrator to view and monitor a variety of SAF-TE related attributes, such as chassis temperature readings, disk failure, and the status of the chassis cooling apparatus (cooling fans). Note: This feature is dependent upon the system chassis – this function will not be available unless the chassis sup ...

  • Highpoint RocketRAID 2320 - page 38

    9 - Managing Events The HighPoint RAID Management Console will log all events that have occurred on any host adapter under it’s control. V iewing Logged Events T o view logged events: 1 . Highlight the “V iew” menu, and select the “Event V iew” option. 2 . In the Event V iew window , you can filer events, clear events, and save events to ...

  • Highpoint RocketRAID 2320 - page 39

    T o add a Recipient: 1 . Highlight the “Management” menu, and select the “Event Notification” function. 2 . Click the “Add” button on the toolbar or select “Add” command from the “Operation” menu. 3 . Enter the necessary information in the Add recipient window . 4 . The recipient will be listed in the main window . Y ou can use ...

  • Highpoint RocketRAID 2320 - page 40

    T o setup and schedule tasks highlight the “Management” menu, and select the “T ask Management” function to open T ask Management window . The T ask Schedule list displays all of the tasks assigned to the selected remote system. T o view detailed information about a specific task, highlight and Double-click the task’s name. Add a Schedule ...

  • Highpoint RocketRAID 2320 - page 41

    Select the task type and the array that you want to verify or rebuild, then click “Next”. RocketRAID 2320 Driver and Software Installation 4-19 ...

  • Highpoint RocketRAID 2320 - page 42

    Enter a name for the task. Configure the frequency for the task. Set the duration for the task. Check the “Enable the task” option to activate this task. Click “Finish”. Modify a Scheduled T ask This command is used to change settings for a scheduled task. T o Modify a T ask Schedule: 1 . Select a task from the T ask schedule list. 2 . Clic ...

  • Highpoint RocketRAID 2320 - page 43

    10 - Configuring Remote Systems Then HighPoint RAID Management Console manages a RAID controller through a connection to the HighPoint RAID Management Service, which runs on the system where the RAID host adapter is physically installed. This type of system is referred to as a “remote system”. Note: What the software classifies as a “remote s ...

  • Highpoint RocketRAID 2320 - page 44

    Modify a Connection This command modifies connection information for a remote system. T o modify a connection: 1 . Highlight the “File” menu and select the “Remote Control” function. 2 . Highlight the system you want to modify. 3 . Click the Modify button on the toolbar or select the “Modify” command from the “Operation” menu. 4 . E ...

  • Highpoint RocketRAID 2320 - page 45

    3 . Click the “Connect” button on the toolbar or select the “Connect” command from the “Operation” menu. 4 . Enter the appropriate Login information in the popup window. Note: The initial user name/passwor d for a r emote system is RAID/hpt. Y ou ar e fr ee to modify the username and password after the connection is established. If the ...

  • Highpoint RocketRAID 2320 - page 46

    System Configuration This function is used to modify the service configuration on a remote system. T o change the service configuration: 1 . Highlight the “File” menu and select the “Remote Control” function. 2 . Highlight the remote system you want to modify. 3 . Select the “System Configuration” option from the “Operation” menu. 4 ...

  • Highpoint RocketRAID 2320 - page 47

    1 1 - Configuring Users and Privileges The RAID Management Console allows the Administrator to manage user accounts in its own database. Y ou can setup multiple users and assign different privileges levels for the purpose of RAID management. Users can be assigned to each individual Remote System controlled by the RAID Management Console. Highlight ...

  • Highpoint RocketRAID 2320 - page 48

    3 . Select the appropriate privileges for the user. 4 . Click “Finish”. Delete a User This function deletes a user’s account on the connected remote system. T o delete a user: 1 . Select the target user ID from the User list displayed in the User Management window. 2 . Click Delete to remove the selected user . Click “Y es” to delete the ...

  • Highpoint RocketRAID 2320 - page 49

    1 . Select the target user ID from the user list displayed in the User Management window. 2 . Click the “Set Password” option, and enter the password for the user. 3 . Click OK to apply your selections. Set Privilege The Administrator uses this function set a user’s privileges for the selected remote system. T o set privileges for a user: 1 . ...

  • Highpoint RocketRAID 2320 - page 50

    Chapter 5 Linux Driver Support Contents of this Chapter: Fedora Core 3 Linux installation Overview Red Hat Enterprise 3 Overview SuSE Linux Enterprise Server (SLES) installation Overview ...

  • Highpoint RocketRAID 2320 - page 51

    1 - Fedora Core 3 Linux installation Overview This section provides instructions describing how to install and utilize the RocketRAID 2320 Adapter on a Fedora Core 3 Linux system. 2 - Installing Fedora Core 3 on the RocketRAID 2320 Host Adapter Note: If the OS is running kernel that differs from the one supported by the precompiled driver, the prec ...

  • Highpoint RocketRAID 2320 - page 52

    2 ) At the “W elcome to Fedora Linux” installation screen, a prompt labeled “boot:” will appear at the bottom of the screen. T ype in linux dd , then press Enter . boot: linux dd 3 ) When prompted “Do you have a driver disk?”, select “Y es”. At the “Insert your driver disk and press OK to continue” prompt, insert the driver disk ...

  • Highpoint RocketRAID 2320 - page 53

    After extracting the driver module, load it using the following commands: # modprobe sd_mod # insmod rr2320.ko Arrays attached to the adapter can be accessed as SCSI devices (e.g. /dev/sda). Step 2 Mounting and Partitioning the Device Example: A RAID array has been configured between several hard disks. This array will be registered to the system a ...

  • Highpoint RocketRAID 2320 - page 54

    #chmod 755 /etc/init.d/hptdriver #ln –sf /etc/init.d/hptdriver /etc/rc.d/rc3.d/S01hptdriver #ln –sf /etc/init.d/hptdriver /etc/rc.d/rc4.d/S01hptdriver #ln –sf /etc/init.d/hptdriver /etc/rc.d/rc5.d/S01hptdriver Step 4 Configure System to Mount V olumes during Startup The system can be instructed to automatically mount the array(s) during start ...

  • Highpoint RocketRAID 2320 - page 55

    1 - Red Hat Enterprise 3 Overview This section provides instructions describing how to install and utilize the RocketRAID 2320 Adapter on a Red Hat Enterprise 3 Linux system. 2 - Installing Red Hat Enterprise 3 (AS, ES, WS) Linux on the RocketRAID 2320 controller T o install Red Hat Enterprise Linux onto disks or RAID arrays attached to RocketRAID ...

  • Highpoint RocketRAID 2320 - page 56

    1 . The system will now load the RocketRAID 2320 driver automatically. 2 . When prompted “Where do you want to install the boot loader? ” in the “Boot Loader Configuration” dialog, select “Master Boot Record (MBR)” to instruct the system be to boot from the RocketRAID 2320. Continue the installation as normal. Y ou can refer to Red Hat ...

  • Highpoint RocketRAID 2320 - page 57

    After you have extracted the driver module, you can load it by following commands: # modprobe sd_mod # insmod rr2320.o Arrays attached to the adapter can be accessed as SCSI devices (e.g. /dev/sda). Step 2 Mounting and Partitioning the Device Example: A RAID array has been configured between several hard disks. This array will be registered to the ...

  • Highpoint RocketRAID 2320 - page 58

    #echo “modprobe rr2320” > /etc/init.d/hptdriver #chmod 755 /etc/init.d/hptdriver #ln –sf /etc/init.d/hptdriver /etc/rc.d/rc3.d/S01hptdriver #ln –sf /etc/init.d/hptdriver /etc/rc.d/rc4.d/S01hptdriver #ln –sf /etc/init.d/hptdriver /etc/rc.d/rc5.d/S01hptdriver Step 4 Configure System to Mount V olumes during Startup The system can be inst ...

  • Highpoint RocketRAID 2320 - page 59

    Example: (2.4.21-4.EL for Red Hat Enterprise Linux 3.0): # gzip -dc /boot/initrd-xxx.img > /tmp/initrd.ext2 # mkdir /mnt/initrd # mount -o loop /tmp/initrd.ext2 /mnt/initrd # cp /tmp/rr2320.o /mnt/initrd/lib/rr2320.o # umount /mnt/initrd # gzip -c /tmp/initrd.ext2 > /boot/initrd-xxx.img If you are using lilo to boot the system, use “lilo” ...

  • Highpoint RocketRAID 2320 - page 60

    1 - SuSE Linux Enterprise Server (SLES) installation Overview This section provides instructions describing how to install and utilize the RocketRAID 2320 Adapter on a SuSE (SLES) Linux system. 2 - Installing SLES Linux on the RocketRAID 2320 Host Adapter Note: If the OS is running kernel that differs from the one supported by the precompiled drive ...

  • Highpoint RocketRAID 2320 - page 61

    4 . When the “Diver Update Menu” is displayed, press “OK” and “back” for back to installer. 5 . Next. Select “back” to return to the installer. 6 . Installation will now proceed normally. Refer to SLES Linux documents for additional OS installation procedures. Additional Installation Notes: The system device mapping order is the sam ...

  • Highpoint RocketRAID 2320 - page 62

    Example: default=0 timeout=8 title Linux kernel (hd0,1)/vmlinux root=/dev/hda1 acpi=off initrd (hd0,1)/initrd Reboot the system to allow the new kernel parameters to take effect. Step 2 Install the Driver Module Extract the module file from the file /linux/suse /[arch]-[version]/install/update.tar.gz (from the driver disk), using the following comm ...

  • Highpoint RocketRAID 2320 - page 63

    Step 3 Mounting and Partitioning the Device Note: Many versions of SuSE include Y AST . Y AST is a graphical configuration utility that is capable of executing the commands described below . W e r ecommend using Y AST , if available, as it may help simplify the installation pr ocess. Example: A RAID array has been configured between several hard di ...

  • Highpoint RocketRAID 2320 - page 64

    Step 5 Configure System to Mount V olumes during Startup The system can be instructed to automatically mount the array(s) during startup by modifying the file”/etc/fstab”. For example, add the following line to tell the system to mount /dev/sda1 to location / mnt/raid after startup: /dev/sda1 /mnt/raid ext2 defaults 0 0 4 - Updating the Driver ...

  • Highpoint RocketRAID 2320 - page 65

    Chapter 6 FreeBSD Driver Support Contents of this Chapter: 1 - Installing FreeBSD on the RocketRAID 2320 Controller 2 - Installing RocketRAID 2320 Driver on an Existing System 3 - Updating the Driver 4 - Uninstalling the Driver ...

  • Highpoint RocketRAID 2320 - page 66

    1 - Installing FreeBSD on the RocketRAID 2320 Controller If you would like to install FreeBSD onto arrays attached to the RocketRAID 2320 host adapter, please follow the steps below. Step 1 Prepare the Driver Diskette When installing FreeBSD to a disk or array attached to the RocketRAID 2320, you must prepare a RocketRAID 2320 driver diskette befor ...

  • Highpoint RocketRAID 2320 - page 67

    BIOS driver B: is disk1 BIOS driver C: is disk2 BIOS 636kB/74512kB available memory FreeBSD/i386 bootstrap loader, Revision 0.8 (mailto:jkh@narf.osd.bsdi.com, Sat Apr 21 08:46:19 GMT 2001) - Hit [Enter] to boot immediately, or any other key for command prompt. Booting [kernel] in 9 seconds… <-pr ess SP ACE key A prompted label “ ok ” will ...

  • Highpoint RocketRAID 2320 - page 68

    for FreeBSD 4.6.2-RELEASE ok load disk1:rr2320-4.6.2.ko for FreeBSD 4.7-RELEASE ok load disk1:rr2320-4.7.ko for FreeBSD 4.8-RELEASE ok load disk1:rr2320-4.8.ko for FreeBSD 4.9-RELEASE ok load disk1:rr2320-4.9.ko for FreeBSD 4.10-RELEASE ok load disk1:rr2320-4.10.ko for FreeBSD 4.11-RELEASE ok load disk1:rr2320-4.1 1.ko for FreeBSD 5.0-RELEASE ok lo ...

  • Highpoint RocketRAID 2320 - page 69

    for FreeBSD 5.2.1-RELEASE ok load disk0:rr2320-5.2.1.ko for FreeBSD 5.3-RELEASE ok load disk0:rr2320-5.3.ko for FreeBSD 5.4-RELEASE ok load disk0:rr2320-5.4.ko for FreeBSD 5.3-AMD64-RELEASE ok load disk0:rr2320-5.3-amd64.ko for FreeBSD 5.4-AMD64-RELEASE ok load disk0:rr2320-5.4-amd64.ko 5 . After the driver has been loaded, remove the floppy disket ...

  • Highpoint RocketRAID 2320 - page 70

    7 . Before exiting installation, an additional step must be taken to copy the RocketRAID 2320 driver module to the system. On the driver diskette, there is a setup script labeled “ postinstall ”, which will complete this task. Before rebooting the system, press Alt-F4 to enter the command shell, and type the following commands: # mount –o ro ...

  • Highpoint RocketRAID 2320 - page 71

    Alternately, it is possible extract the files from the .img files directly, without using a floppy diskette: For FreeBSD 4.x: # vnconfig vn0c freebsd_xxx.img # mount /dev/vn0c /mnt # cp /mnt/rr2320-xxx.ko /modules/rr2320.ko # vnconfig –du vn0c myfilesystem mount=/mnt For FreeBSD 5.x: # mdconfig –a –t vnode –f freebsd_5.x.img –u 0 # mount ...

  • Highpoint RocketRAID 2320 - page 72

    >> FreeBSD/i386 BOOT Default: 0:ad(0,a)/boot/loader boot: BTX loader 1.00 BTX version is 1.01 Console: internal video/keyboard BIOS driver A: is disk0 BIOS driver C: is disk2 BIOS 636kB/74512kB available memory FreeBSD/i386 bootstrap loader, Revision 0.8 (mailto:jkh@narf.osd.bsdi.com, Sat Apr 21 08:46:19 GMT 2001) Loading /boot/defaults/loade ...

  • Highpoint RocketRAID 2320 - page 73

    Note: If you have configured a RAID 10 using 4 disks, it will be registered to system as device /dev/da0 . Y ou can use “ /stand/sysinstall ” to cr eate partitions and disklabels (like da0s1e) on da0 . Then, create a new filesystem using “ newfs /dev/ da0s1e ”. Now you can mount /dev/da0s1e to somewhere to access it Step 3 Configur e System ...

  • Highpoint RocketRAID 2320 - page 74

    3 - Updating the Driver T o update the driver with a newer revision, simply reinstall the driver following the steps discussed in the previous section, “Install the driver on an existing system”. 4 - Uninstalling the Driver The driver can only be uninstalled when the system is not booting from devices attached to the RocketRAID 2320 controller ...

  • Highpoint RocketRAID 2320 - page 75

    Appendix Customer Support ...

  • Highpoint RocketRAID 2320 - page 76

    Customer Support If you encounter any problems while utilizing the RocketRAID 2320, or have any questions about this or any other HighPoint product, feel free to contact our Cus- tomer Support Department. T roubleshooting Checklist Before contacting our Customer Support department: Make sure the latest BIOS, driver and RAID Software have been insta ...

  • Highpoint RocketRAID 2320 - page 77

    FCC Part 15 Class B Radio Frequency Interference statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and ca ...

Manufacturer Highpoint Category Controller

Documents that we receive from a manufacturer of a Highpoint RocketRAID 2320 can be divided into several groups. They are, among others:
- Highpoint technical drawings
- RocketRAID 2320 manuals
- Highpoint product data sheets
- information booklets
- or energy labels Highpoint RocketRAID 2320
All of them are important, but the most important information from the point of view of use of the device are in the user manual Highpoint RocketRAID 2320.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Highpoint RocketRAID 2320, service manual, brief instructions and user manuals Highpoint RocketRAID 2320. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Highpoint RocketRAID 2320.

A complete manual for the device Highpoint RocketRAID 2320, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Highpoint RocketRAID 2320 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Highpoint RocketRAID 2320.

A complete Highpoint manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Highpoint RocketRAID 2320 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Highpoint RocketRAID 2320, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Highpoint RocketRAID 2320, that we can find in the current document
3. Tips how to use the basic functions of the device Highpoint RocketRAID 2320 - which should help us in our first steps of using Highpoint RocketRAID 2320
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Highpoint RocketRAID 2320
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Highpoint RocketRAID 2320 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Highpoint RocketRAID 2320?

Use the form below

If you did not solve your problem by using a manual Highpoint RocketRAID 2320, ask a question using the form below. If a user had a similar problem with Highpoint RocketRAID 2320 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)