    58YAV Induced-Combustion Furnaces Service and Maintenance Instructions For Sizes 070-155, Series 110 and 120 NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS SAFETY CONSIDERATIONS .....................................................1 INTRODUCTION .......................................................... ...

  • Carrier INDUCED COUSTION 58YAV - page 2

    ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE Electrostatic discharge can affect electronic components. Take precautions during furnace installation and servicing to protect the furnace electronic control. Precautions will pre- vent electrostatic discharges from personnel and hand tools which are held during the procedure. These precautions w ...

  • Carrier INDUCED COUSTION 58YAV - page 3

    d. If equipped with permanent, washable filter, clean filter by spraying cold tap water through filter in opposite direction of airflow. Rinse filter and let dry. Oiling or coating of the filter is not recommended. e. If equipped with factory-specified disposable media filter, replace only with media filter having the same part number and size. f. ...

  • Carrier INDUCED COUSTION 58YAV - page 4

    14. If furnace is operating properly, REMOVE TAPE TO RE- LEASE BLOWER ACCESS DOOR SWITCH, replace blower access door. Step 3—Cleaning Heat Exchanger The following steps should be performed by a qualified service technician: NOTE: If the heat exchangers get a heavy accumulation of soot and carbon, they should be replaced rather than trying to clea ...

  • Carrier INDUCED COUSTION 58YAV - page 5

    10. Clean flame sensor with fine steel wool 11. Remove old sealant from center panel and collector box flange and apply new sealant to collector box flange and reinstall on center panel, making sure all 8 screws are secure. NOTE: A releasing agent such as PAM cooking spray or equiva- lent (must not contain corn or canola oil, aromatic or halogenate ...

  • Carrier INDUCED COUSTION 58YAV - page 6

    Fig. 6—Unit Wiring Diagram A00304 PCB BLOWER OFF DELAY SELECTION CHART 90 SEC 135 SEC 180 SEC 225 SEC GVR H I/LO RELA Y SEC-1 SEC-2 PL1 3 2 1 6 5 4 9 87 LED TEST/TWIN BLOWER OFF DELAY G R Y W C HUM HSI R I DR BLWR BLOWER SPEED SELECT FU1 COOL HEA T L2 PL3 PL2 VAC 120 L1 PR1 1 2 1 2 3 PR2 24 VAC -3A FUSE SP AR E-2 SP ARE-1 EAC-1 EAC-2 C 1.5 AMP 12 ...

  • Carrier INDUCED COUSTION 58YAV - page 7

    through the sight glass or window on the blower access door. The control indicates status with the LED on continuously, rapid flashing, or a code composed of 2 digits. (The first digit is the number of short flashes, the second is the number of longs flashes.) For an explanation of status codes, refer to service label (See Fig. 8) located on blower ...

  • Carrier INDUCED COUSTION 58YAV - page 8

    Fig. 8—Service Label A99233 SER VICE G R Y W Com HUM TEST LED LED CODE ST A TUS 24V 11 12 13 14 21 22 23 24 31 33 34 * 9 8 6 5 32 1 4 7 COMPONENT TEST NO PREVIOUS CODE - Stored status codes are erased when pow er (115V AC or 24V AC) to control is interrupted or 48 hours after each f ault is cleared. BLO WER ON AFTER PO WER UP (115V A C or 24 V A ...

  • Carrier INDUCED COUSTION 58YAV - page 9

    Blower access door switch opens 115-v power to control. No component operation can occur. Caution must be taken when manually closing this switch for service purposes. Failure to follow this warning could result in personal injury or death. d. BRIEFLY short (jumper) TEST, 3/16 in. quick connect terminal on control (adjacent to LED status light), an ...

  • Carrier INDUCED COUSTION 58YAV - page 10

    Troubleshooting Guide A99123a Is circuit breaker closed? Close door switch and go to start. Is red LED status light on? Is door switch closed? Is red LED status light blinking rapidly without a pause? Is there 1 15v going to switch? Replace door switch. Replace control center . Replace transformer . Is red LED status light blinking ON/OFF slowly wi ...

  • Carrier INDUCED COUSTION 58YAV - page 11

    A99123b 11 NO PREVIOUS F A UL T - Faults are erased after 48 hrs or whenever power (1 15v or 24v) is interrupted. Run system through a heating or cooling cycle to check system. 12 BLO WER ON AFTER PO WER UP (115V OR 24V) - Normal operation. Blower will run for 90 sec when furnace power is interrupted during a call for heat, R-W closed. 13 LIMIT OR ...

  • Carrier INDUCED COUSTION 58YAV - page 12

    Copyright 2000 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 58yav3sm Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Tab 6a 8a PC 101 Catalog No. 535-771 Printed in U.S.A. Form 58YAV–3SM Pg 12 10-00 Replaces: 58YAV–2SM ...

Manufacturer Carrier Category Furnace

Documents that we receive from a manufacturer of a Carrier INDUCED COUSTION 58YAV can be divided into several groups. They are, among others:
- Carrier technical drawings
- INDUCED COUSTION 58YAV manuals
- Carrier product data sheets
- information booklets
- or energy labels Carrier INDUCED COUSTION 58YAV
All of them are important, but the most important information from the point of view of use of the device are in the user manual Carrier INDUCED COUSTION 58YAV.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Carrier INDUCED COUSTION 58YAV, service manual, brief instructions and user manuals Carrier INDUCED COUSTION 58YAV. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Carrier INDUCED COUSTION 58YAV.

A complete manual for the device Carrier INDUCED COUSTION 58YAV, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Carrier INDUCED COUSTION 58YAV by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Carrier INDUCED COUSTION 58YAV.

A complete Carrier manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Carrier INDUCED COUSTION 58YAV - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Carrier INDUCED COUSTION 58YAV, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Carrier INDUCED COUSTION 58YAV, that we can find in the current document
3. Tips how to use the basic functions of the device Carrier INDUCED COUSTION 58YAV - which should help us in our first steps of using Carrier INDUCED COUSTION 58YAV
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Carrier INDUCED COUSTION 58YAV
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Carrier INDUCED COUSTION 58YAV in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Carrier INDUCED COUSTION 58YAV?

Use the form below

If you did not solve your problem by using a manual Carrier INDUCED COUSTION 58YAV, ask a question using the form below. If a user had a similar problem with Carrier INDUCED COUSTION 58YAV it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)