  • FMI VSHRN18T - page 1

    For more information, visit www .fmiproducts.com W ARNING: If the information in this manual is not followed exactly , a re or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance. — WHA T TO DO IF YO ...

  • FMI VSHRN18T - page 2

    www .fmiproducts.com 12531 1-01A 2 This appliance may be in - stalled in an aftermarket,* p e r m a n e n t l y l o c a t e d , manufactured (mobile) home, where not prohib - ited by local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer WARNING: This product con - tains and/or generates chemicals known to ...

  • FMI VSHRN18T - page 3

    www .fmiproducts.com 12531 1-01A 3 Keep the appliance area clear and free from combustible ma - terials, gasoline and other am - mable vapors and liquids. 1. This appl ianc e is only for use with the type of ga s indi cate d on the rati ng pla te. Th is appl ianc e is no t convert ible fo r use with othe r ga ses. 2. Do not place propane/LP supp ...

  • FMI VSHRN18T - page 4

    www .fmiproducts.com 12531 1-01A 4 SAFETY Continued Figure 1 - V ent-Free Gas Heater (actual heater may vary from illustration 14. Before using furniture polish, wax, carpet clea ner or simil ar produ cts, turn hea ter off . If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furni - ...

  • FMI VSHRN18T - page 5

    www .fmiproducts.com 12531 1-01A 5 AIR FOR COMB USTION AND VENTILA TION W ARN ING: T his he ate r shall no t be in st all ed in a ro om or spa ce unless the required volume of in - doo r combu stio n air is provi ded by t he m etho d de scr ibed in t he Nat ion al Fue l Gas Co de, AN SI Z223.1/NFP A 54, the Int ern at io na l Fuel Gas Code, or appl ...

  • FMI VSHRN18T - page 6

    www .fmiproducts.com 12531 1-01A 6 DETERMINING FRESH-AIR FLOW FOR HEA TER LOCA TION Determining if Y ou Have a Conned or Unconned Space Use this work sheet to determine if you have a conned or unconned space. Space: Include s the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation gril ...

  • FMI VSHRN18T - page 7

    www .fmiproducts.com 12531 1-01A 7 V entilation Air From Outdoors Pr ovi de ex tra fres h air by usi ng ven tila tio n gr ill s or ducts. Y ou must provide two permanent openings: one within 12" (30.5 cm) of the ceil - AIR FOR COMB USTION AND VENTILA TION Continued Figure 2 - V entilation Air from Inside Building Figure 3 - V entilation Air fr ...

  • FMI VSHRN18T - page 8

    www .fmiproducts.com 12531 1-01A 8 LOCA TING HEA TER T hi s h e at e r i s d es i gn e d t o b e m ou n te d on a w al l . W ARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from oor , ceiling and joining wall. Y ou can locate heater on oor , away from a wall. An optional oor mounting stand ...

  • FMI VSHRN18T - page 9

    www .fmiproducts.com 12531 1-01A 9 INST ALLA TION Continued Figure 6 - Mounting Bracket Figure 8 - Mounting bracket Clearances Figu re 7 - Remo ving Fron t Pa nel of H eate r (actual heater may vary from Illustration) INST ALLING HEA TER TO W ALL Mounting Bracket Locate mounting bracket in heater carton. Re - move mounting bracket from heater carto ...

  • FMI VSHRN18T - page 10

    www .fmiproducts.com 12531 1-01A 10 INST ALLA TION Continued Figure 9 - Folding Anchor Figure 1 1 - Mounting Heater onto Mounting Bracket Figure 10 - Popping Open Anchor Wings for Thin Walls Figure 12 - Installing Bottom Mounting Screws Attaching T o W all Anchor Method For attaching mounting bracket to hollow walls (wall areas betwee n stud s) or ...

  • FMI VSHRN18T - page 11

    www .fmiproducts.com 12531 1-01A 11 IMPORT ANT : For natural gas, check gas line pres sure before conne cting heater to gas line. Gas line pressure must be no greater than 10.5" W .C.. If gas line pressure is higher , heater regulator damage could occur . CAUTION: For propane/LP gas, never connect heater di - re ctl y to th e p rop ane /LP su ...

  • FMI VSHRN18T - page 12

    www .fmiproducts.com 12531 1-01A 12 CHECKING GAS CONNECTIONS W ARN ING : T est all gas pipi ng and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. W ARNING: Never use an open ame to check for a leak. Apply a noncorrosive leak detec - tion uid to all joints. Bubbles forming show a ...

  • FMI VSHRN18T - page 13

    www .fmiproducts.com 12531 1-01A 13 Equipment Shutoff Va lve Propane/LP Supply T ank Thermostat Gas V alve Equipment Shutoff V alve Gas Meter Thermostat Gas V alve INST ALLA TION Continued 2. Cap off open end of gas pipe wher e equip - ment shutoff valve was connected. 3. Pressuri ze supply piping system by either opening propane/LP supply tank val ...

  • FMI VSHRN18T - page 14

    www .fmiproducts.com 12531 1-01A 14 OPERA TION in the safety information, column 1. If you don’t smell gas, go to the next step. 6. Thermostat Models: T ur n co ntr ol kn ob counterclockwise to the PILOT po si ti on . Pr es s in c on tr ol k no b for  ve (5 ) se co nds . Manual Models: P re ss i n an d tu rn c on tr ol knob counterclockwise to ...

  • FMI VSHRN18T - page 15

    www .fmiproducts.com 12531 1-01A 15 10. T o shut off burners only and leave pilot lit, turn control knob clockwise to the PILOT position. W ARNING: Always operate manual control heaters at the locked positions. Operation between these positions may create a possible health hazard if used in a poorly ventilated room. Read owner ’ s manual for comp ...

  • FMI VSHRN18T - page 16

    www .fmiproducts.com 12531 1-01A 16 OPERA TION Continued THERMOST A T CONTROL OPERA TION The thermostatic control used on these models dif fers from standard thermostats. Standard thermostats simply turn on and off the burn er . The the rmos tat used on this heat er senses the room temperature. At times the room may exceed the set temperature. If s ...

  • FMI VSHRN18T - page 17

    www .fmiproducts.com 12531 1-01A 17 W ARNING: Failure to keep the prim ary air openin g(s) of the burner(s) clean may result in sooting and property damage. ODS/PILOT AND BURNER Use a vacuum cleaner , pressurized air or small, soft bristled brush to clean. BURNER PILOT AIR INLET T he p ri m a r y a i r i n le t h ol e s al l o w t h e pr o pe r am ...

  • FMI VSHRN18T - page 18

    www .fmiproducts.com 12531 1-01A 18 We also recommend that you keep the burner tube and pilot assem bly clean and free of dust and dirt. T o clean these parts we recommend using compressed air no greater than 30 PSI. Y our local computer store, hardware store or home center may carry compressed air in a can. If using compressed air in a can, please ...

  • FMI VSHRN18T - page 19

    www .fmiproducts.com 12531 1-01A 19 TROUBLESHOO TING WAR NI NG : Tu rn off and unp lu g he at er and let coo l be fo re ser vi cin g. Only a qualied service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in ...

  • FMI VSHRN18T - page 20

    www .fmiproducts.com 12531 1-01A 20 TROUBLESHOO TING Continued OBSERVED PROBLEM ODS/pilot lights but flame goes out when control knob is released Bur ner d oes no t lig ht af ter ODS/pilot is lit Delayed ignition of burner Burner backring during com - bustion Burner plaque(s) does not glow Slight smoke or odor during initial operation Heater pro ...

  • FMI VSHRN18T - page 21

    www .fmiproducts.com 12531 1-01A 21 W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • D o n o t t o u c h a n y e l e c t r i c a l s w i t c h ; d o n o t u s e a n y p h o n e i n y o u r b u i l d i n g . • Immediately call your gas supplier from a neighbor ’ s phone. Fol - low the gas supplier ? ...

  • FMI VSHRN18T - page 22

    www .fmiproducts.com 12531 1-01A 22 P ARTS CABINET BODY MODELS GWRP16C, GWRN18C, GWRP26C, GWRN30C, GWRP16TC, GWRN18TC, GWRP26TC, GWRN30TC, VSHRP16M, VSHRP16T , VSHRN18M, VSHRN18T , VSHRP26M, VSHRP26T , VSHRN30M, AND VSHRN30T 11 8 5 6 7 4 3 1 2 16 10 12 13 9 17 14 15 19 18 20 Replacement may vary from grill shown See page 24 See Pages 24 and 25 Actu ...

  • FMI VSHRN18T - page 23

    www .fmiproducts.com 12531 1-01A 23 P ARTS This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 107673-01 Front Panel • • • • 1 107676-01 Front Panel • • • • 1 2 103476-01 Grill Guard • ...

  • FMI VSHRN18T - page 24

    www .fmiproducts.com 12531 1-01A 24 P ARTS BURNER ASSEMBL Y This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 27 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 120630-02 ODS/Pilot LP • 1 120630-03 ODS/Pilot NG • 1 2 098200-03 Control V alve Brack ...

  • FMI VSHRN18T - page 25

    www .fmiproducts.com 12531 1-01A 25 P ARTS BURNER ASSEMBL Y This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 27 of this manual. GWRP26C, VSHRP26M GWRN30C, VSHRN30M KEY NO. P ART NO. DESCRIPTION QTY . 1 120630-02 ODS/Pilot LP • 1 120630-03 ODS/Pilot NG ? ...

  • FMI VSHRN18T - page 26

    www .fmiproducts.com 12531 1-01A 26 P ARTS BURNER ASSEMBL Y This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 27 of this manual. 5 6 4 3 2 1 5 4 6 3 2 1 5 KEY NO. P ART NO. DESCRIPTION QTY . 1 120630-02 ODS/Pilot LP • 1 120630-03 ODS/Pilot NG • 1 2 0993 ...

  • FMI VSHRN18T - page 27

    www .fmiproducts.com 12531 1-01A 27 TECHNICAL SERVICE You may have further questions about installa - ti on, ope rat ion or tro ub les hoot in g. If so, cont act FMI PRODUCTS, LLC at 1-866- 328-4537. When calling please have your model and serial numbers of your heater ready. Y ou can also visit our web site at www .fmiproducts.com . SERVICE HINTS ...

  • FMI VSHRN18T - page 28

    12531 1-01 Rev . A 05/10 WARRANTY kEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES New Products Standard Warranty: FM I P RO DU CT S, L LC wa rr a nt s th is ne w pr od u ct an d a ny pa rt s t he re of t o be fr ee fr om d ef ec ts i n ma te r ia l an d w or km a ns hi p fo r a pe ri od o f fo ur ( 4) y ea rs f ro m th e da t e of r st ...

Manufacturer FMI Category Gas Heater

Documents that we receive from a manufacturer of a FMI VSHRN18T can be divided into several groups. They are, among others:
- FMI technical drawings
- VSHRN18T manuals
- FMI product data sheets
- information booklets
- or energy labels FMI VSHRN18T
All of them are important, but the most important information from the point of view of use of the device are in the user manual FMI VSHRN18T.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals FMI VSHRN18T, service manual, brief instructions and user manuals FMI VSHRN18T. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product FMI VSHRN18T.

Similar manuals

A complete manual for the device FMI VSHRN18T, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use FMI VSHRN18T by users. Manuals are usually written by a technical writer, but in a language understandable to all users of FMI VSHRN18T.

A complete FMI manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual FMI VSHRN18T - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the FMI VSHRN18T, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the FMI VSHRN18T, that we can find in the current document
3. Tips how to use the basic functions of the device FMI VSHRN18T - which should help us in our first steps of using FMI VSHRN18T
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with FMI VSHRN18T
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of FMI VSHRN18T in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning FMI VSHRN18T?

Use the form below

If you did not solve your problem by using a manual FMI VSHRN18T, ask a question using the form below. If a user had a similar problem with FMI VSHRN18T it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)