    1 Hotwire  5620 RTU Customer Premises Installation Instructions Document Number 5620-A2-GN1 1-30 August 2000 Contents What Does the Hotwire 5620 RTU Do? 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the DSL Access Wiring 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the Hotwire ...

  • Paradyne 5620-A2-GN11-30 - page 2

    2 NOTES: In this document: — End-user system is used to represent any host with an Ethernet connection. — Service provider is used to represent any Internet Service Provider (ISP) or remote LAN access provider . DSL Access without a POTS Splitter When the Hotwire 5620 RTU is installed without a POTS splitter , the DSL line is used for data only ...

  • Paradyne 5620-A2-GN11-30 - page 3

    3 DSL Access with a Hotwire 5030 or 5038 POTS Splitter When a Hotwire POTS splitter is used at both ends of the local loop, wiring is connected:  From the demarcation point to the CP POTS splitter , and  From the demarcation point to the DSL jack. The Hotwire 5030 POTS Splitter is designed for outdoor or indoor installation. The Hotwire 5038 ...

  • Paradyne 5620-A2-GN11-30 - page 4

    4 DSL Access with a Hotwire 5038 Distributed POTS Splitter When a Hotwire 5038 Distributed POTS Splitter is used, one 5038 Distributed POTS Splitter is installed as a phone filter for each telephone on the same POTS line as DSL. 00-16727 RTU Customer Premises (CP) Central Office (CO) Local Loop POTS Splitter T o End-user Systems DSL – Digital Sub ...

  • Paradyne 5620-A2-GN11-30 - page 5

    5 Package Checklist V erify that your package contains the following:  Model 5620 Remote T ermination Unit (RTU)  DSL interface cable with RJ1 1 modular plugs  Power cord with power transformer Wiring and Cables Y ou Need The following wiring and standard connectors are used with this product:  Standard RJ1 1 wall jack for the DSL cabli ...

  • Paradyne 5620-A2-GN11-30 - page 6

    6 Installing the DSL Access Wiring The local loop terminates at the punchdown block or NID. Wiring must be connected from the customer premises side of the punchdown block or the NID to an RJ1 1 jack. T ypically , the punchdown block is installed in commercial locations and the NID is installed in residential locations.  Procedur e 1. Access the ...

  • Paradyne 5620-A2-GN11-30 - page 7

    7 3. Locate the DSL pair of T1/R1 connectors on the customer premises side of the NID or punchdown block. Attach the wiring that will be connected to the DSL jack. In the following example, a NID is used without a POTS splitter . It includes an existing POTS line and a second pair installed for DSL access. DSL/PO TS Access from Local Loop Wiring to ...

  • Paradyne 5620-A2-GN11-30 - page 8

    97-15300a RJ11 W all Jack or 8 Connecting to the DSL Access Wiring The Hotwire 5620 RTU connects to the local loop via wiring from the demarcation point to an RJ1 1 wall jack. The DSL twisted-pair wiring from the local loop terminates at a new or existing wall jack. It may be necessary to install a standard single RJ1 1 jack or replace a single jac ...

  • Paradyne 5620-A2-GN11-30 - page 9

    9 Installing the Hotwire 5620 R TU Place the Hotwire 5620 RTU on a flat surface with clearance for the rear connectors.  Procedur e 1. Use the supplied RJ1 1 6-pin interface cable for the DSL connection. Insert one end of the cable into the jack labeled DSL. Insert the other end into the wall jack labeled DSL. 97-15300-01 DSL Jack POWER ETHERNET ...

  • Paradyne 5620-A2-GN11-30 - page 10

    10 2. Use an 8-pin Ethernet cable for the Ethernet connection. Insert one end of the cable into the jack labeled ETHERNET .  Use a straight-through cable to connect the other end to an Ethernet hub. Do not connect to the optional Uplink connection with a straight-through cable (requires an Ethernet crossover cable). 00-15303-02 Ethernet Line PO ...

  • Paradyne 5620-A2-GN11-30 - page 11

    11 3. Insert the supplied power cord’s round end into the jack labeled POWER. Plug the transformer into an AC outlet. 98-15836 PO WER ETHERNET DSL Hotwire RTU Po w e r Jack or T ransformer or The RTU hardware installation is now complete. When the power cord is installed, the RTU goes through a power-on self-test. Power -On When power is applied, ...

  • Paradyne 5620-A2-GN11-30 - page 12

    12 Status LEDs All of the LEDs turn on and off during the power-on self-test. After a successful self-test, the LEDs should appear as indicated in BOLD in the Condition column below . LED Condition Status PWR ON The RTU has power . ALM OFF ON No active alarms. An alarm condition exists. TST OFF ON No active tests. The TST LED is on during the power ...

  • Paradyne 5620-A2-GN11-30 - page 13

    13 T roubleshooting LED Symptom Action All LEDs are on. If the LEDs remain on for more than ten minutes, the RTU is not functional. Unplug the unit and reapply power . If the ALM LED is still on, contact the service provider . ALM LED remains on. The power-on self-test may have failed. Unplug the unit and reapply power . If the alarm LED is still o ...

  • Paradyne 5620-A2-GN11-30 - page 14

    98-15304-01 6-Pin RJ11 Plug DSL Cable Pin #1 Pin #6 14 Increasing the Number of End-User Systems A single end-user system is attached to the Hotwire 5620 RTU by using an Ethernet crossover cable. T o increase the number of end-user systems, connect all end-user systems to an Ethernet hub using a straight-through cable. The Hotwire 5620 RTU can supp ...

  • Paradyne 5620-A2-GN11-30 - page 15

    98-16055a 8-Pin Plug Ethernet Cable Pin #1 Pin #8 15  Ethernet interface connector uses an 8-pin, non-keyed modular plug. Use shielded twisted-pair CA T5 or better cables. — T o connect to an Ethernet hub, use the straight-through connection. 8-Pin Straight-Through Connection Pin # Function 1 10BaseT TX D+ 2 10BaseT TX D– 3 10BaseT RX D+ 4 & ...

  • Paradyne 5620-A2-GN11-30 - page 16

    16 Optional R TU W all Placement The Hotwire 5620 RTU is designed for tabletop placement. The R TU can also be mounted on a wall. T o mount an RTU, you will need: - Three slotted-head #6 self-threading screws with molly bolts - Drill and 3/16 ″ drill bit for the molly bolts - Screwdriver A template with the dimensions for the three screws is prov ...

  • Paradyne 5620-A2-GN11-30 - page 17

    17 R TU Hardware T emplate F ront (LEDs) 98-16171 5.43" 7.55" T o Bottom Hole ...

  • Paradyne 5620-A2-GN11-30 - page 18

    18 Technical Specifications for Model 5620 R TU Item Specification * Height x Width x Depth 1.25 ″ x 6.00 ″ x 8.75 ″ (3.18 cm x 15.24 cm x 22.23 cm) Weight 1 lb. 1 oz. (0.48 kg) Power Class 2 T ransformer normal service input voltage range Input: 100 V AC (+ 10%), 50 Hz; 120 V AC (+ 10%), 60 Hz; or 230 V AC (+ 10%), 50/60 Hz Output: 18 VDC no ...

  • Paradyne 5620-A2-GN11-30 - page 19

    19 ! Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. T o ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. 3. Do ...

  • Paradyne 5620-A2-GN11-30 - page 20

    20 CE Marking When the product is marked with the CE mark on the equipment label, this demonstrates full compliance with the following European Directives:  Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within states relating t ...

  • Paradyne 5620-A2-GN11-30 - page 21

    21 Declaration of Conformity This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2 and 15 of the Federal Communications Commission’s Rules. This compliance information statement pertains to the following products: T rade Name: Hotwire Model Number: 5620-A3-200 This device complies with Part 15 of the FCC Rules. Operat ...

  • Paradyne 5620-A2-GN11-30 - page 22

    22 Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be included in the installation and operation manual. Specific instructions are listed in the following sections. United States – Notice to Users of the T elephone Network 1. This equipment complies with Part 68 of the FCC ru ...

  • Paradyne 5620-A2-GN11-30 - page 23

    23 7. The user is not authorized to repair or modify the equipment. 8. This equipment cannot be used on public coin service provided by the telephone company . Connection to Party Line Service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information.) 9. An FCC co ...

  • Paradyne 5620-A2-GN11-30 - page 24

    24 W arranty , Sales, Service, and T raining Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty , sales, service, repair , installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one ...

Manufacturer Paradyne Category Tablet Accessory

Documents that we receive from a manufacturer of a Paradyne 5620-A2-GN11-30 can be divided into several groups. They are, among others:
- Paradyne technical drawings
- 5620-A2-GN11-30 manuals
- Paradyne product data sheets
- information booklets
- or energy labels Paradyne 5620-A2-GN11-30
All of them are important, but the most important information from the point of view of use of the device are in the user manual Paradyne 5620-A2-GN11-30.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Paradyne 5620-A2-GN11-30, service manual, brief instructions and user manuals Paradyne 5620-A2-GN11-30. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Paradyne 5620-A2-GN11-30.

Similar manuals

A complete manual for the device Paradyne 5620-A2-GN11-30, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Paradyne 5620-A2-GN11-30 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Paradyne 5620-A2-GN11-30.

A complete Paradyne manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Paradyne 5620-A2-GN11-30 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Paradyne 5620-A2-GN11-30, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Paradyne 5620-A2-GN11-30, that we can find in the current document
3. Tips how to use the basic functions of the device Paradyne 5620-A2-GN11-30 - which should help us in our first steps of using Paradyne 5620-A2-GN11-30
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Paradyne 5620-A2-GN11-30
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Paradyne 5620-A2-GN11-30 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Paradyne 5620-A2-GN11-30?

Use the form below

If you did not solve your problem by using a manual Paradyne 5620-A2-GN11-30, ask a question using the form below. If a user had a similar problem with Paradyne 5620-A2-GN11-30 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)