    340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140 Product Data The model 340AAV Multipoise Condensing Furnace is specifi- cally designed to meet the needs of the new construction market. This high-efficiency furnace utilizes a unique 4-way multipoise design and compact size to fit where other fur- naces will not. The ...

  • Bryant 340AAV - page 2

    —2— 340AAV A05070 NO TE S : 1. Minim u m ret u rn - a ir opening s a t f u rn a ce, bas ed on met a l d u ct. If flex d u ct i s us ed, s ee flex d u ct m a n u f a ct u rerí s recommend a tion s f or e qu iv a lent di a meter s . 2. Minim u m ret u rn - a ir opening a t f u rn a ce: a .F o r 8 00 CFM–16-in. ro u nd or 14 1 / 2 x 12-in. rect ...

  • Bryant 340AAV - page 3

    —3— 340AAV Thi s for ced ai r fur nac e i s equi pped for use w i th natur al gas at alt i t udes 0 - 10, 000 f t (0 - 3, 050m), except 140 si ze F ur naces a re only approved for alt it udes 0 - 7,000 ft . (0 - 2,135m). An acce ssor y ki t, sup pl i ed by the manuf act ur er , sha ll be used to co nver t t o propan e gas use or ma y be requi r ...

  • Bryant 340AAV - page 4

    —4— 340AAV Controls—Thermostats and Zoning Non-Programmable Thermostat Selection * Model HP and 2S thermostat must be field converted to air conditioner operation. **Thermidistat Control is versatile and can be configured for multiple use and staging, it must be configured for each specific application. Programmable Thermostat Selection * Mod ...

  • Bryant 340AAV - page 5

    —5— 340AAV SPECIFICATIONS See notes on page 7. UNIT SIZE 024040 036040 024060 036060 048060 036080 RATINGS AND PERFORMANCE Input Btuh* 40,000 40,000 60,000 60,000 60,000 80,000 Output Capacity BTUH* (ICS) (Shaded capacities are specified on rat- ing plate) Direct Vent (2-Pipe) Upflow 37,000 37,000 56,000 56,000 56,000 74,000 Downflow 37,000 37, ...

  • Bryant 340AAV - page 6

    —6— 340AAV SPECIFICATIONS See notes on page 7. UNIT SIZE 048080 060080 048100 060100 060120 060140 RATINGS AND PERFORMANCE Input Btuh* 80,000 80,000 100,000 100,000 120,000 140,000 Output Capacity BTUH* (ICS) (Shaded capacities are specified on rat- ing plate) Direct Vent (2-Pipe) Upflow 74,000 74,000 93,000 93,000 112,000 127,000 Downflow 74,0 ...

  • Bryant 340AAV - page 7

    —7— 340AAV * Gas input ratings are certified for elev ations to 2000 ft. F or elevations abo ve 2000 ft, reduce ratings 2% f or each 1000 ft above sea le vel. In Canada, derate the unit 5% from 2000 to 4500 ft abov e sea lev el. † Capacity and AFUE in accordance with U .S. Government DOE test procedures. ‡ Airflow shown is f or bottom onl ...

  • Bryant 340AAV - page 8

    —8— 340AAV COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications MAXIMUM ALLOWABLE PIPE LENGTH (FT) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.)* PIPE DIA (IN.)* 12 3 4 5 6 ...

  • Bryant 340AAV - page 9

    —9— 340AAV COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.)* PIPE DIA (IN.)* ...

  • Bryant 340AAV - page 10

    —1 0— 340AAV COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.)* PIPE DIA (IN. ...

  • Bryant 340AAV - page 11

    —1 1— 340AAV MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* * Pipe length (ft) specified for maximum vent pipe lengths located in unconditioned spaces. Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as specified in Maximum Allowable Pipe ...

  • Bryant 340AAV - page 12

    —1 2— 340AAV ACCESSORIES SIDE FILTER RACK* DIMENSIONS (In.) * Dimension A will change accordingly as dimension D is lengthened or shortened. † Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in. minimum. * The plenum should be constructed 1/4 in. smaller in widt ...

  • Bryant 340AAV - page 13

    —1 3— 340AAV AIR DELIVERY—CFM (With Filter)* * A filter is required f or each return-air supply . • For horiz ontal and downflow applications , use “1 side or bottom ” or “bottom only ” as airflow ref erence. UNIT SIZE RETURN-AIR SUPPLY SPEED EXTERNAL STATIC PRESSURE (In. wc) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 024040 1 side or botto ...

  • Bryant 340AAV - page 14

    —1 4— 340AAV COMBU S TION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GA S -FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE COMBU S TION AIR INLET (NON-DIRECT 1-PIPE APPLICATION) A05064 ELECTRONIC AIR CLEANER HUMIDIFIER A/C COIL VENT COMBU S TION AIR (DIRECT VENT/ 2 PIPE APPLICATION OU ...

  • Bryant 340AAV - page 15

    —1 5— 340AAV COMBU S TION–AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDEN S ATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE A05066 DIRECT VENT/2-PIPE APPLICATION) COMBU S TION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) COMBU S TION– AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) VENT PIPE ELECTRONIC AIR ...

  • Bryant 340AAV - page 16

    —1 6— ©Bryant Heating & Cooling systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. edition date: 01/06 Catalog No. PDS 340A.40.2 Manufacturer reserves the right to change, at any time, specifications or designs without notice and obligations Replaces: PDS 340A.40.1 GENERAL System Description Furnish a _________________ (4- ...

Manufacturer Bryant Category Furnace

Documents that we receive from a manufacturer of a Bryant 340AAV can be divided into several groups. They are, among others:
- Bryant technical drawings
- 340AAV manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant 340AAV
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant 340AAV.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant 340AAV, service manual, brief instructions and user manuals Bryant 340AAV. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant 340AAV.

Similar manuals

A complete manual for the device Bryant 340AAV, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant 340AAV by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant 340AAV.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant 340AAV - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant 340AAV, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant 340AAV, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant 340AAV - which should help us in our first steps of using Bryant 340AAV
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant 340AAV
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant 340AAV in a specific country, if it was not possible to solve the problem on our own.