Manual Zephyr CTP-E54SX

23 pages 0.63 mb
Download

Go to site of 23

Summary
  • Zephyr CTP-E54SX - page 1

    T rapeze C TP-E 4 8SX C TP-E54SX C TP-E 6 0SX Model number: Serial number: U s e , C a r e , a n d I n s ta l la tion G u id e MAY07.0101 © Zep h yr Corpo ration. ww w .zephyronline.com Date of Purchase: Sales Dealer: ...

  • Zephyr CTP-E54SX - page 2

    www .zephyronline.com ...

  • Zephyr CTP-E54SX - page 3

    T able of Contents 1 SAFET Y NO TICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specifi ...

  • Zephyr CTP-E54SX - page 4

    www .zephyronline.com Im p or tan t s afety N o t i c e 2 TO R ED U C E T H E R I S K O F F I R E O R E L E C TR IC SH OC K, D O N O T USE T H IS FAN W ITH ANY S O L I D-S T ATE SP E E D CONTRO L DE V I C E . TO R E DUC E T H E R I S K O F F I R E, E L E C T R IC SH O C K, O R I NJ U R Y TO P E R S ON S, O B S E RVE T H E F O L LO W I N G: a. Use t ...

  • Zephyr CTP-E54SX - page 5

    Li s t o f M a t e r ia l s 3 MODEL: CTP-ExxS 1 - Hood 2 - Bae Filters 4 - G U-10, 120V 50 W , halogen bulbs 2 - Utensil Rails 2 - T elescopic Duct Covers 4 - T elescopic Rods Sets 4 - Angle Bra c kets (27 3/8”) 4 - Angle Bra c kets (35 3/8”) 1 - Ceiling Mounting Bra c ket 1 - Internal Flange 1 - Motor Housing 1 - HARDWARE PACKET 4 - Coupler ...

  • Zephyr CTP-E54SX - page 6

    www .zephyronline.com 4 I n s t a lla t io n - Duct wo rk C a lcula t io n S h e e t Duct pieces To t a l Equivalent number length x used = 31 / 4 ”x1 0 ” Rect., straight 1 F t . x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 90 0 elbow 15 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 31 / 4 ...

  • Zephyr CTP-E54SX - page 7

    5 I n s ta lla tion - M o unt i ng H e i ght & C l e a ra nc e DUC T I N G 9" 36" Min 98"-Max 124” Min 28"-Max 36" Min 34"-Max 52" Minimum mount height between range top to hood b ot- tom should be no less than 28". Maximum mount height should be no higher than 36". It is important to install the h ...

  • Zephyr CTP-E54SX - page 8

    www .zephyronline.com 6 I n s t a lla t io n - Du ct ing WARNING FIRE HAZARD N EV E R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork onl y . F asten all connections with sheet metal screws and tape all joints w/ ce ...

  • Zephyr CTP-E54SX - page 9

    15 3/4” 9“ “ 6 “ 9 ” 2 5 x a M - “ 4 3 n i M 26 5/8” 32” 48” , 54” , 59 1/8” Min 21” - Max 40” 12 1/8” 7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 2” 2” 7/64” 13/32” 32“ “ 9 ” 6 1 / 7 0 1 ” 2 / 1 9 9“ ” 8 / 1 4 R ” 2 3 / 5 1 ” 8 / 3 1 ” 4 6 / 1 2 0 1 O 10“ 11 3/4“ ...

  • Zephyr CTP-E54SX - page 10

    www .zephyronline.com I n s t a lla t io n - In t er n a l B l ow er 8 The internal blower kit consists of the blower and capacitor box with wiring. A TTE NTI O N The following are intructions for installing internal blower model CB I-600. F or instructions on preparing for external blower model CB E-1000 please turn to page “10” . Before insta ...

  • Zephyr CTP-E54SX - page 11

    I n s t a lla t io n - In t er n a l B l ow er 9 6. Attach junction box to internal ange using provided 1/2” self tapping screws and 4mm internal diameter washers. 7 . Att ac h grounding wires from junction box and motor to grounding screw as shown. 8. Place blower with attached ange into motor housing as shown on Fig-A. 9. Attach using 1/2 ...

  • Zephyr CTP-E54SX - page 12

    www .zephyronline.com 10 I n s t a lla t io n - P re p a rin g H o o d fo r E xt e rn a l B lo we r The external blower kit consists of an 8” collar , external ange and external blower wiring box. T he external blower is purchased separately. A TTE NTI O N The following are instructions on preparing your hood for installation with e xternal bl ...

  • Zephyr CTP-E54SX - page 13

    11 In s ta l l at i o n - M o unt i ng t he H o o d All Electrical work must by performed by qualied electrician or person with similar technical know how and bac kgr ound. F or personal saf ety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow Nationa ...

  • Zephyr CTP-E54SX - page 14

    12 I n s t a lla t io n - M o u n ti n g th e H o o d 1. Mount motor housing to the range hood b ody using (10) 1/2” self tapping screws. 2. Determine height of hood, measure and select either 27 3/8” or 35 3/8” angle brac kets and attach (4) of them to the motor housing using (8) 1/2” self tapping screws (2) for each angle brac ket. 3. Sli ...

  • Zephyr CTP-E54SX - page 15

    13 I n s t a lla t io n - M o u n ti n g th e H o o d 5. Lift assembled unit and atta ch all (4) angle bra ckets to ceiling bra cket. Make sure the tabs on eac h angle bra ckets are facing the outside. T he angle brackets will t between the slots on the ceiling bra cket. One half of the angle bra cket will be on the outside of the ceiling bra ck ...

  • Zephyr CTP-E54SX - page 16

    I n s t a lla t io n - M o u n ti n g th e H o o d 14 Utensil Rail Installation 1. A ttach utensil rail to long side of hood canopy . A small hole has been pre-drilled into the canopy to provide a starting point to attach the rst utensil rail post. A fter the rst post is line up with the hole, gently slide the rest of the rail onto canopy . ( ...

  • Zephyr CTP-E54SX - page 17

    18 F ea t u r e s & C on t r ol s - T ou c h C on t r ol s & F e a t u r es The standard Bae Filters are required to be cleaned frequently and as recommended in order to maintain blower eciency . If improperly maintained, residue from cooking will sift though lters and cause damage to hood blo wers and other sensitive components; a ...

  • Zephyr CTP-E54SX - page 18

    16 Filter Clean Reminder (Standard Bae Filters tted): A set of bae lters are tted by the factory . These Bae Filters are intended to lter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the microprocessor will automatically indicate ...

  • Zephyr CTP-E54SX - page 19

    www .zephyronline.com 17 M a int e n a nce - C le aning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. F or heavier soil use liquid degreaser . After cleaning, you may use non-abrasive stainless steel ...

  • Zephyr CTP-E54SX - page 20

    18 Ma i n t e n an c e - Lights R eplacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. DO NO T touch bulbs until switc hed o and cooled. T ouching hot bulbs may cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip together, the lig ...

  • Zephyr CTP-E54SX - page 21

    www .zephyronline.com T r ou b le S h oot in g 19 After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Filter is vibrating. After hood has been installed for a period of time, it stopped working. 1. The power so ...

  • Zephyr CTP-E54SX - page 22

    20 www .zephyronline.com Halogen Bulb G U-10, 120V, 50W Z0B-0020 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-00TP List of Parts and Accessories Part Description Part # Accessory Description Part # ...

  • Zephyr CTP-E54SX - page 23

    www.zephyronline.com Warranty One Y ear Service Repair W arr anty: F or one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or components due to manufacturing defects. T wo Y ears P arts W arranty: F or two years from date of original purchase, we will provide free of charge, nonconsumab ...

Manufacturer Zephyr Category Ventilation Hood

Documents that we receive from a manufacturer of a Zephyr CTP-E54SX can be divided into several groups. They are, among others:
- Zephyr technical drawings
- CTP-E54SX manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr CTP-E54SX
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr CTP-E54SX.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr CTP-E54SX, service manual, brief instructions and user manuals Zephyr CTP-E54SX. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr CTP-E54SX.

Similar manuals

A complete manual for the device Zephyr CTP-E54SX, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr CTP-E54SX by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr CTP-E54SX.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr CTP-E54SX - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr CTP-E54SX, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr CTP-E54SX, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr CTP-E54SX - which should help us in our first steps of using Zephyr CTP-E54SX
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr CTP-E54SX
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr CTP-E54SX in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr CTP-E54SX?

Use the form below

If you did not solve your problem by using a manual Zephyr CTP-E54SX, ask a question using the form below. If a user had a similar problem with Zephyr CTP-E54SX it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)